The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Short‐Term Effects of Biocorrodible Iron Stents in Porcine Coronary Arteries
Abstract
Background: Biocorrodible iron stents carry the potential to overcome limitations, such as chronic inflammation and premature recoil, posed by biodegradable polymer and magnesium alloy stents. This study aimed to test the safety and efficacy of biocorrodible iron stents in porcine coronary arteries. Methods: Iron stents and cobalt chromium stents were randomly deployed in the coronary arteries of juvenile domestic pigs. Animals were sacrificed at 28 days, and the vessels were fixed and processed for histochemistry. Results: At 28 days, iron stents started to show signs of degradation without evidence of stent particle embolization or thrombosis without traces of excess inflammation, or fibrin deposition. At 28 days, the surface of the iron stent struts was black to brown and the vascular wall adjacent to the iron stent had a brownish tinge. There were no statistically significant differences in any of the measured parameters between segments implanted with iron and cobalt chromium stents. There were also no adverse effects in the persistent areas. Conclusion: The current study demonstrates that stents made of biocorrodible iron are safe. In some of the measured parameters, such as intimal thickness, intimal area, and percentage occlusion, there was a trend in favor of the iron stents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andrews, N. C. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912233412607 · Cited by 2,130
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Developments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Antibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Metadata
- Authors
- WAKSMAN, R., PAKALA, R., BAFFOUR, R., SEABRON, R., HELLINGA, D., & TIO, F. O.
- Venue
- Journal of Interventional Cardiology
- Publisher
- Wiley
- Published
- 2007-12-13
- Volume
- 21
- Issue
- 1
- Pages
- 15-20
- ISSN
- 0896-4327 (ISSN-L)
- 1540-8183
- OpenAlex
- W2039650401
- Cited by
- 244
- References
- 1
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Short‐Term Effects of Biocorrodible Iron Stents in Porcine Coronary Arteries. https://app.cochat.ai/papers/10.1111/j.1540-8183.2007.00319.x
- The paper
- WAKSMAN, R., PAKALA, R., BAFFOUR, R., SEABRON, R., HELLINGA, D., & TIO, F. O. (2008). Short‐Term Effects of Biocorrodible Iron Stents in Porcine Coronary Arteries. Journal of Interventional Cardiology. https://doi.org/10.1111/j.1540-8183.2007.00319.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.