Short‐Term Effects of Biocorrodible Iron Stents in Porcine Coronary Arteries
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Background: Biocorrodible iron stents carry the potential to overcome limitations, such as chronic inflammation and premature recoil, posed by biodegradable polymer and magnesium alloy stents. This study aimed to test the safety and efficacy of biocorrodible iron stents in porcine coronary arteries. Methods: Iron stents and cobalt chromium stents were randomly deployed in the coronary arteries of juvenile domestic pigs. Animals were sacrificed at 28 days, and the vessels were fixed and processed for histochemistry. Results: At 28 days, iron stents started to show signs of degradation without evidence of stent particle embolization or thrombosis without traces of excess inflammation, or fibrin deposition. At 28 days, the surface of the iron stent struts was black to brown and the vascular wall adjacent to the iron stent had a brownish tinge. There were no statistically significant differences in any of the measured parameters between segments implanted with iron and cobalt chromium stents. There were also no adverse effects in the persistent areas. Conclusion: The current study demonstrates that stents made of biocorrodible iron are safe. In some of the measured parameters, such as intimal thickness, intimal area, and percentage occlusion, there was a trend in favor of the iron stents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Andrews, N. C. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912233412607 · Cited by 2,130
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Late Clinical Events After Clopidogrel Discontinuation May Limit the Benefit of Drug-Eluting Stents
Pfisterer, M., Brunner-La Rocca, H. P., Buser, P. T., Rickenbacher, P., Hunziker, P., Mueller, C., Jeger, R., Bader, F., Osswald, S., & Kaiser, C. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.026 · Cited by 1,303
Schwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
Clopidogrel Use and Long-term Clinical Outcomes After Drug-Eluting Stent Implantation
Eisenstein, E. L., Anstrom, K. J., Kong, D. F., Shaw, L. K., Tuttle, R. H., Mark, D. B., Kramer, J. M., Harrington, R. A., Matchar, D. B., Kandzari, D. E., et al. (2007) · JAMA · doi:10.1001/jama.297.2.joc60179 · Cited by 870
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Developments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Antibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Progress of biodegradable metals
Li, H., Zheng, Y., & Qin, L. (2014) · Progress in Natural Science: Materials International · doi:10.1016/j.pnsc.2014.08.014 · Cited by 432
Current status and outlook on the clinical translation of biodegradable metals
Han, H.-S., Loffredo, S., Jun, I., Edwards, J., Kim, Y.-C., Seok, H.-K., Witte, F., Mantovani, D., & Glyn-Jones, S. (2019) · Materials Today · doi:10.1016/j.mattod.2018.05.018 · Cited by 423
Yang, H., Wang, C., Liu, C., Chen, H., Wu, Y., Han, J., Jia, Z., Lin, W., Zhang, D., Li, W., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.08.022 · Cited by 399
Liu, B., & Zheng, Y. F. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.001 · Cited by 396
Fe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆
Hermawan, H., Purnama, A., Dube, D., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.025 · Cited by 372
Endothelial Cellular Responses to Biodegradable Metal Zinc
Ma, J., Zhao, N., & Zhu, D. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00319 · Cited by 275
Bioresorbable scaffolds: rationale, current status, challenges, and future
Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht542 · Cited by 269
Self-citationRecent Advances in Biodegradable Metals for Medical Sutures: A Critical Review
Seitz, J., Durisin, M., Goldman, J., & Drelich, J. W. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500189 · Cited by 243
Cardiovascular stents: overview, evolution, and next generation
Borhani, S., Hassanajili, S., Ahmadi Tafti, S. H., & Rabbani, S. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0097-y · Cited by 226
Kopova, I., Stráský, J., Harcuba, P., Landa, M., Janeček, M., & Bačákova, L. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.11.043 · Cited by 204
Zhao, S., McNamara, C. T., Bowen, P. K., Verhun, N., Braykovich, J. P., Goldman, J., & Drelich, J. W. (2017) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-016-3901-0 · Cited by 201
A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials
Pierson, D., Edick, J., Tauscher, A., Pokorney, E., Bowen, P., Gelbaugh, J., Stinson, J., Getty, H., Lee, C. H., Drelich, J., et al. (2012) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31922 · Cited by 195
“Magnesium and iron stents degrade into physiological products, are immunologically inert, and possess physical properties that are more similar to commercial stainless steel stents and cobalt chromium alloys than polymer bioabsorbable stent candidate materials.(7,20,21) In contrast to iron, which experiences a relativ…”
BackgroundInfluentialLin, W., Qin, L., Qi, H., Zhang, D., Zhang, G., Gao, R., Qiu, H., Xia, Y., Cao, P., Wang, X., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.03.020 · Cited by 183
Biomaterials‐Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, M., & Bettinger, C. J. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200071 · Cited by 182
Continuum damage model for bioresorbable magnesium alloy devices — Application to coronary stents
Gastaldi, D., Sassi, V., Petrini, L., Vedani, M., Trasatti, S., & Migliavacca, F. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.003 · Cited by 173
Chen, Y., Zhang, W., Maitz, M. F., Chen, M., Zhang, H., Mao, J., Zhao, Y., Huang, N., & Wan, G. (2016) · Corrosion Science · doi:10.1016/j.corsci.2016.05.039 · Cited by 172
Bioresorbable Stents: Is This Where We Are Headed?
Wayangankar, S. A., & Ellis, S. G. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2015.08.011 · Cited by 18
Metadata
- Authors
- WAKSMAN, R., PAKALA, R., BAFFOUR, R., SEABRON, R., HELLINGA, D., & TIO, F. O.
- Venue
- Journal of Interventional Cardiology
- Publisher
- Wiley
- Published
- 2007-12-13
- Volume
- 21
- Issue
- 1
- Pages
- 15-20
- ISSN
- 0896-4327 (ISSN-L)
- 1540-8183
- OpenAlex
- W2039650401
- Cited by
- 244
- References
- 19
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.