CoChat

Correlation of Noninvasive Electrocardiography with Invasive Electrophysiology in Syncope of Unknown Origin: Implications from a Large Syncope Database

Open access
Gatzoulis, Konstantinos A., Karystinos, George, Gialernios, Theodoros, Sotiropoulos, Helias, Synetos, Andreas, Dilaveris, Polychronis, Sideris, Skevos, Kalikazaros, Ioannis, Olshansky, Brian, Stefanadis, Christodoulos I. · 2009 · Annals of Noninvasive Electrocardiology
Cited by 35

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Background: The evaluation of syncope can be expensive, unfocussed, and unrevealing yet, failure to diagnose an arrhythmic cause of syncope is a major problem. We investigate the utility of noninvasive electrocardiographic evaluation (12‐lead ECG and 24‐hour ambulatory electrocardiographic recordings) to predict electrophysiology study results in patients with undiagnosed syncope. Methods: We evaluated 421 patients with undiagnosed syncope who had an electrocardiogram (ECG), an electrophysiology study, and 24‐hour ambulatory monitoring. Noninvasive testing was used to predict electrophysiology testing outcomes. Multivariable logistic regression analysis adjusting for age, sex, presence of heart disease, and left ventricular ejection fraction (LVEF) was used to assess independent predictors for sinus node disease, atrioventricular node disease, and induction of ventricular tachyarrhythmias. Results: Patients were divided into four groups: group 1, abnormal ECG and ambulatory monitor; group 2, abnormal ECG only; group 3, abnormal ambulatory monitor; and group 4, normal ECG and ambulatory monitor. The likelihood of finding at least one abnormality during electrophysiologic testing among the four groups was highest in group 1 (82.2%) and lower in groups 2 and 3 (68.1% and 33.7%, respectively). In group 4, any electrophysiology study abnormality was low (9.1%). Odds ratios (OR) were 35.9 (P < 0.001), 17.8 (P < 0.001), and 3.5 (P = 0.064) for abnormal findings on electrophysiology study, respectively (first three groups vs the fourth one). ECG and ambulatory monitor results predicted results of electrophysiology testing. Conclusion: Abnormal ECG findings on noninvasive testing are well correlated with potential brady‐ or/and tachyarrhythmic causes of syncope, in electrophysiology study of patients with undiagnosed syncope.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1542-474x.2009.00286.x

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 35

Metadata

Authors
Gatzoulis, K. A., Karystinos, G., Gialernios, T., Sotiropoulos, H., Synetos, A., Dilaveris, P., Sideris, S., Kalikazaros, I., Olshansky, B., & Stefanadis, C. I.
Venue
Annals of Noninvasive Electrocardiology
Publisher
Wiley
Published
2009-04
Volume
14
Issue
2
Pages
119-127
ISSN
  • 1082-720X (ISSN-L)
  • 1542-474X
OpenAlex
W2107496679
Cited by
35
References
16
FWCI
1.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlation of Noninvasive Electrocardiography with Invasive Electrophysiology in Syncope of Unknown Origin: Implications from a Large Syncope Database. https://app.cochat.ai/papers/10.1111/j.1542-474x.2009.00286.x
The paper
Gatzoulis, K. A., Karystinos, G., Gialernios, T., Sotiropoulos, H., Synetos, A., Dilaveris, P., Sideris, S., Kalikazaros, I., Olshansky, B., & Stefanadis, C. I. (2009). Correlation of Noninvasive Electrocardiography with Invasive Electrophysiology in Syncope of Unknown Origin: Implications from a Large Syncope Database. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/j.1542-474x.2009.00286.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.