Reliability of Ultra‐Short ECG Indices for Heart Rate Variability
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Background: Heart rate variability (HRV) is an accepted and reliable means for assessing autonomic nervous system dysfunction. A 5‐minute measurement of HRV is considered methodologically adequate. Several studies have attempted to use shorter recordings of 1–2 minutes or 10 seconds. The aim of this study was to determine the reliability of HRV parameters calculated from ultra‐short electrocardiogram recordings. Methods: Seventy healthy volunteers were recruited for the study. HRV was evaluated for 5 minutes according to accepted procedures. Thereafter, HRV parameters were recalculated from randomly selected 1‐minute and 10‐second intervals. The standard and ultra‐short measurements were correlated using intraclass correlation coefficients. Results: Good correlations between the 5‐minute electrocardiograms (ECGs) and both the 1‐minute and 10‐second ECGs were noted for average RR interval, and root mean square of successive differences in RR intervals (RMSSD). No correlation was noted for standard deviation of the RR interval (SDNN) and several other HRV parameters. Conclusions: RMSSD, but not SDNN, seem a reliable parameter for assessing HRV from ultra‐short (1 minute or 10 seconds) resting electrocardiographic recordings. Power spectral analysis and evaluation of other HRV parameters require longer recording periods. Further research is required to evaluate the importance of ultra‐short RMSSD for cardiovascular risk stratification. Ann Noninvasive Electrocardiol 2011;16(2):117–122
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Heart rate variability: measurement and clinical utility.
Kleiger, R. E., Stein, P. K., & Bigger, J. T. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.10101.x · Cited by 1,290
Dekker, J. M., Schouten, E. G., Klootwijk, P., Pool, J., Swenne, C. A., & Kromhout, D. (1997) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009049 · Cited by 512
Ultra short term analysis of heart rate variability for monitoring mental stress in mobile settings.
Salahuddin, L., Cho, J., Jeong, M. G., & Kim, D. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353378 · Cited by 374
Carnethon, M. R., Golden, S. H., Folsom, A. R., Haskell, W., & Liao, D. (2003) · Circulation · doi:10.1161/01.cir.0000066324.74807.95 · Cited by 270
Confidence Limits for Intraclass Reliability Coefficients
Baumgartner, T. A., & Chung, H. (2001) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0503_4 · Cited by 249
Quantitative studies of autonomic function
Hilz, M. J., & Dütsch, M. (2006) · Muscle & Nerve · doi:10.1002/mus.20365 · Cited by 232
Repeatability of heart rate variability measures
Schroeder, E. B., Whitsel, E. A., Evans, G. W., Prineas, R. J., Chambless, L. E., & Heiss, G. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.04.004 · Cited by 170
Sosnowski, M., & Petelenz, T. (1995) · Journal of Electrocardiology · doi:10.1016/s0022-0736(05)80263-8 · Cited by 78
Min, K. B., Min, J., Paek, D., Cho, S., & Son, M. (2008) · International Heart Journal · doi:10.1536/ihj.49.175 · Cited by 59
Carnethon, M. R. (2002) · American Journal of Epidemiology · doi:10.1093/aje/155.1.48 · Cited by 58
Reproducibility of Resting Heart Rate Variability With Short Sampling Periods
Marks, B. L., & Lightfoot, J. T. (1999) · Canadian Journal of Applied Physiology · doi:10.1139/h99-026 · Cited by 53
Karp, E., Shiyovich, A., Zahger, D., Gilutz, H., Grosbard, A., & Katz, A. (2009) · Cardiology · doi:10.1159/000235568 · Cited by 50
Heart rate variability in familial Mediterranean fever
Nussinovitch, N., Livneh, A., Katz, K., Langevitz, P., Feld, O., Nussinovitch, M., Volovitz, B., Lidar, M., & Nussinovitch, U. (2009) · Rheumatology International · doi:10.1007/s00296-009-1214-y · Cited by 26
Self-citationFujiwara, Y., Ito, H., Asakura, Y., Sato, Y., Nishiwaki, K., & Komatsu, T. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000258756.41649.2d · Cited by 20
Dekker, J. M., de Vries, E. L., Lengton, R. R., Schouten, E. G., Swenne, C. A., & Maan, A. C. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00281.x · Cited by 17
(1996) · PubMed
Cited by
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
Monitoring training status with HR measures: do all roads lead to Rome?
Buchheit, M. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00073 · Cited by 879
Heart Rate Variability in Psychology: A Review of HRV Indices and an Analysis Tutorial
Pham, T., Lau, Z. J., Chen, S. H. A., & Makowski, D. (2021) · Sensors · doi:10.3390/s21123998 · Cited by 480
Validity of (ultra-)short recordings for heart rate variability measurements.
Munoz, M. L., van Roon, A., Riese, H., Thio, C., Oostenbroek, E., Westrik, I., de Geus, E. J. C., Gansevoort, R., Lefrandt, J., Nolte, I. M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138921 · Cited by 423
Baek, H. J., Cho, C.-H., Cho, J., & Woo, J.-M. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2014.0104 · Cited by 315
Metadata
- Authors
- Nussinovitch, U., Elishkevitz, K. P., Katz, K., Nussinovitch, M., Segev, S., Volovitz, B., & Nussinovitch, N.
- Venue
- Annals of Noninvasive Electrocardiology
- Publisher
- Wiley
- Published
- 2011-04
- Volume
- 16
- Issue
- 2
- Pages
- 117-122
- ISSN
- 1082-720X (ISSN-L)
- 1542-474X
- OpenAlex
- W1913253923
- Cited by
- 249
- References
- 19
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.