Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.

Validity of (ultra-)short recordings for heart rate variability measurements.

Open access
Munoz, M. Loretto, van Roon, Arie, Riese, Harriëtte, Thio, Chris, Oostenbroek, Emma, Westrik, Iris, de Geus, Eco J. C., Gansevoort, Ron, Lefrandt, Joop, Nolte, Ilja M., Snieder, Harold · 2015 · PLOS ONE

Abstract

OBJECTIVES: In order to investigate the applicability of routine 10s electrocardiogram (ECG) recordings for time-domain heart rate variability (HRV) calculation we explored to what extent these (ultra-)short recordings capture the "actual" HRV. METHODS: The standard deviation of normal-to-normal intervals (SDNN) and the root mean square of successive differences (RMSSD) were measured in 3,387 adults. SDNN and RMSSD were assessed from (ultra)short recordings of 10s(3x), 30s, and 120s and compared to 240s-300s (gold standard) measurements. Pearson's correlation coefficients (r), Bland-Altman 95% limits of agreement and Cohen's d statistics were used as agreement analysis techniques. RESULTS: Agreement between the separate 10s recordings and the 240s-300s recording was already substantial (r = 0.758-0.764/Bias = 0.398-0.416/d = 0.855-0.894 for SDNN; r = 0.853-0.862/Bias = 0.079-0.096/d = 0.150-0.171 for RMSSD), and improved further when three 10s periods were averaged (r = 0.863/Bias = 0.406/d = 0.874 for SDNN; r = 0.941/Bias = 0.088/d = 0.167 for RMSSD). Agreement increased with recording length and reached near perfect agreement at 120s (r = 0.956/Bias = 0.064/d = 0.137 for SDNN; r = 0.986/Bias = 0.014/d = 0.027 for RMSSD). For all recording lengths and agreement measures, RMSSD outperformed SDNN. CONCLUSIONS: Our results confirm that it is unnecessary to use recordings longer than 120s to obtain accurate measures of RMSSD and SDNN in the time domain. Even a single 10s (standard ECG) recording yields a valid RMSSD measurement, although an average over multiple 10s ECGs is preferable. For SDNN we would recommend either 30s or multiple 10s ECGs. Future research projects using time-domain HRV parameters, e.g. genetic epidemiological studies, could calculate HRV from (ultra-)short ECGs enabling such projects to be performed at a large scale.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0138921

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Representation of the 10s, 30s and 120s recordings selected from the total recording period (240s–300s).
Fig 1 Representation of the 10s, 30s and 120s recordings selected from the total recording period (240s–300s).CC BY · PubMed Central
Fig 2 Biases and 95% LoAs milliseconds(ms) of the log-transformed (a) SDNN [in blue] and (b) RMSSD [in red] measured from the recordings with different time lengths compared to the total recording. The diamonds are the observed bias and the lines represent the intervals defined by the observed 95%LoAs. The bands show the 95% reference ranges of the simulated biases and the dark gray bands show the 95% reference ranges of the upper and lower 95%LoAs from the simulation. The dotted lines represent the intervals defined by the simulated 95%LoAs. For both SDNN and RMSSD for all recording lengths the observed biases did not differ from the expectation, but the observed 95%LoAs were much narrower than expected.
Fig 2 Biases and 95% LoAs milliseconds(ms) of the log-transformed (a) SDNN [in blue] and (b) RMSSD [in red] measured from the recordings with different time lengths compared to the total recording. The diamonds are the observed bias and the lines represent the intervals defined by the observed 95%LoAs. The bands show the 95% reference ranges of the simulated biases and the dark gray bands show the 95% reference ranges of the upper and lower 95%LoAs from the simulation. The dotted lines represent the intervals defined by the simulated 95%LoAs. For both SDNN and RMSSD for all recording lengths the observed biases did not differ from the expectation, but the observed 95%LoAs were much narrower than expected.CC BY · PubMed Central
Fig 3 Agreement statistics of the natural logarithm of SDNN (blue dashed line) and RMSSD (red solid line) measured from the recordings with different time lengths compared to the total recording. Agreement is measured using (a) Pearson’s correlation coefficient, and (b) Cohen’s d statistic. The error bars (orange for RMSSD; green for SDNN) represent 95% confidence intervals of the mean. The red solid line band (representing RMSSD) and the blue dashed line band (representing SDNN) are the expected values under the null hypothesis as a result of our simulation analysis. For both SDNN and RMSSD for all recording lengths the observed correlations were considerably larger than expected under the null hypothesis, but the Cohen’s ds for both SDNN and RMSSD did not differ from the expectation.
Fig 3 Agreement statistics of the natural logarithm of SDNN (blue dashed line) and RMSSD (red solid line) measured from the recordings with different time lengths compared to the total recording. Agreement is measured using (a) Pearson’s correlation coefficient, and (b) Cohen’s d statistic. The error bars (orange for RMSSD; green for SDNN) represent 95% confidence intervals of the mean. The red solid line band (representing RMSSD) and the blue dashed line band (representing SDNN) are the expected values under the null hypothesis as a result of our simulation analysis. For both SDNN and RMSSD for all recording lengths the observed correlations were considerably larger than expected under the null hypothesis, but the Cohen’s ds for both SDNN and RMSSD did not differ from the expectation.CC BY · PubMed Central
Fig 4 Measurement error of the log transformed values for SDNN (blue dots) calculated as the difference between the total recording and: (a) a 10s recording; (b) the average of the three 10s recording; (c) the 30s recording; (d) the 120s recording. The x-axis is the log transformed SDNN of the total block and the y-axis is the bias of the (ultra-)short recording for log transformed SDNN compared to the gold standard. The grey shaded area represents the interval between the 95%LoA and the white line represents the bias. The black horizontal line is the reference line of no bias (y = 0).
Fig 4 Measurement error of the log transformed values for SDNN (blue dots) calculated as the difference between the total recording and: (a) a 10s recording; (b) the average of the three 10s recording; (c) the 30s recording; (d) the 120s recording. The x-axis is the log transformed SDNN of the total block and the y-axis is the bias of the (ultra-)short recording for log transformed SDNN compared to the gold standard. The grey shaded area represents the interval between the 95%LoA and the white line represents the bias. The black horizontal line is the reference line of no bias (y = 0).CC BY · PubMed Central
Fig 5 Measurement error of the log transformed values for RMSSD (red dots) calculated as the difference between the total recording and: (a) a 10s recording; (b) the average of the three 10s recording; (c) the 30s recording; (d) the 120s recording. The x-axis is the log transformed RMSSD of the total block and the y-axis is the bias of the (ultra-)short recording for log transformed RMSSD compared to the gold standard. The grey shaded area represents the interval between the 95%LoA and the white line represents the bias. The horizontal black line is the reference line of no bias (y = 0).
Fig 5 Measurement error of the log transformed values for RMSSD (red dots) calculated as the difference between the total recording and: (a) a 10s recording; (b) the average of the three 10s recording; (c) the 30s recording; (d) the 120s recording. The x-axis is the log transformed RMSSD of the total block and the y-axis is the bias of the (ultra-)short recording for log transformed RMSSD compared to the gold standard. The grey shaded area represents the interval between the 95%LoA and the white line represents the bias. The horizontal black line is the reference line of no bias (y = 0).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 423

Metadata

Authors
Munoz, M. L., van Roon, A., Riese, H., Thio, C., Oostenbroek, E., Westrik, I., de Geus, E. J. C., Gansevoort, R., Lefrandt, J., Nolte, I. M., & Snieder, H.
Affiliations
University Medical Center Groningen (NL)
Corresponding author
  • Nolte, Ilja M.
  • Snieder, Harold
Venue
PLOS ONE
Published
2015-09-28
Volume
10
Issue
9
Pages
e0138921
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2298185395
Cited by
423
References
27
Citations by year
2026: 80 · 2025: 55 · 2024: 47 · 2023: 33 · 2022: 45 · 2021: 51 · 2020: 32 · 2019: 26 · 2018: 26 · 2017: 17 · 2016: 8
FWCI
12.36
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (publishedVersion, cc-by)
  • VU Research Portal (publishedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
heart rate variability, time-domain HRV, SDNN, RMSSD, measurement agreement, method validation, autonomic nervous system, adults, limits of agreement
MeSH terms
Adult, Demography, Electrocardiography, Female, Heart Rate, Humans, Male, Middle Aged, Statistics as Topic, Time Factors, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity of (ultra-)short recordings for heart rate variability measurements. https://app.cochat.ai/papers/10.1371/journal.pone.0138921
The paper
Munoz, M. L., van Roon, A., Riese, H., Thio, C., Oostenbroek, E., Westrik, I., de Geus, E. J. C., Gansevoort, R., Lefrandt, J., Nolte, I. M., & Snieder, H. (2015). Validity of (ultra-)short recordings for heart rate variability measurements. PLOS ONE. https://doi.org/10.1371/journal.pone.0138921

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.