Can Cardiac Sonography and Capnography Be Used Independently and in Combination to Predict Resuscitation Outcomes?
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objective: To measure the ability of cardiac sonography and capnography to predict survival of cardiac arrest patients in the emergency department (ED). Methods: Nonconsecutive cardiac arrest patients prospectively underwent either cardiac ultrasonography alone or in conjunction with capnography during cardiopulmonary resuscitation at two community hospital EDs with emergency medicine residency programs. Cardiac ultrasonography was carried out using the subxiphoid view during pauses for central pulse evaluation and end‐tidal carbon dioxide (ETCO2) levels were monitored by a mainstream capnograph. A post‐resuscitation data collection form was completed by each of the participating clinicians in order to assess their impressions of the facility of performance and benefit of cardiac sonography during nontraumatic cardiac resuscitation. Results: One hundred two patients were enrolled over a 12‐month period. All patients underwent cardiac sonographic evaluation, ranging from one to five scans, during the cardiac resuscitation. Fifty‐three patients also had capnography measurements recorded. The presence of sonographically identified cardiac activity at any point during the resuscitation was associated with survival to hospital admission, 11/41 or 27%, in contrast to those without cardiac activity, 2/61 or 3% (p < 0.001). Higher median ETCO2 levels, 35 torr, were associated with improved chances of survival than the median ETCO2 levels for nonsurvivors, 13.7 torr (p < 0.01). The multivariate logistic regression model, which evaluated the combination of cardiac ultrasonography and capnography, was able to correctly classify 92.4% of the subjects; however, of the two diagnostic tests, only capnography was a significant predictor of survival. The stepwise logistic regression model, summarized by the area under the receiver operator curve of 0.9, furthermore demonstrated that capnography is an outstanding predictor of survival. Conclusions: Both the sonographic detection of cardiac activity and ETCO2 levels higher than 16 torr were significantly associated with survival from ED resuscitation; however, logistic regression analysis demonstrated that prediction of survival using capnography was not enhanced by the addition of cardiac sonography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
End-Tidal Carbon Dioxide Concentration during Cardiopulmonary Resuscitation
Falk, J. L., Rackow, E. C., & Weil, M. H. (1988) · New England Journal of Medicine · doi:10.1056/nejm198803103181005 · Cited by 466
End-Tidal Carbon Dioxide and Outcome of Out-of-Hospital Cardiac Arrest
Levine, R. L., Wayne, M. A., & Miller, C. C. (1997) · New England Journal of Medicine · doi:10.1056/nejm199707313370503 · Cited by 464 · cited 3×
“The median ETCO2 value of 35 torr in this study mirrors mean ETCO2 levels in survivors in prior studies, which ranged from 31 torr to 33 torr.(11,13) In comparison with previous studies in which nonsurvivors had mean ETCO2 levels ranging from 4.”
BackgroundResultAortic Pressure during Human Cardiac Arrest
Paradis, N. A., Martin, G. B., Goetting, M. G., Rivers, E. P., Feingold, M., & Nowak, R. M. (1992) · CHEST Journal · doi:10.1378/chest.101.1.123 · Cited by 115
Echocardiographic observations during inhospital cardiopulmonary resuscitation
Varriale, P., & Maldonado, J. M. (1997) · Critical Care Medicine · doi:10.1097/00003246-199710000-00023 · Cited by 113 · cited 2×
“Our data support the hypothesis that the demonstration of cardiac standstill is associated with an unsuccessful resuscitation, whereas the detection of cardiac output is associated with an improved likelihood of survival.(1,13) Cardiac sonography may have other uses in the evaluation of cardiac arrest patients.”
BackgroundResultEnd-tidal carbon dioxide during extremely low cardiac output
Idris, A. H., Staples, E. D., O’Brien, D. J., Melker, R. J., Rush, W. J., Duca, K. D. D., & Falk, J. L. (1994) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(94)70080-x · Cited by 100
Prognostic Value Of End-Tidal Carbon Dioxide Pressures During Out-Of-Hospital Cardiac Arrest
Asplin, B. R., & White, R. D. (1995) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(95)70203-2 · Cited by 61 · cited 2×
“Higher ETCO2 values have been associated with return of spontaneous circulation.(7,11,14) Our capnography results (Table 1) add to this evidence base by demonstrating that higher ETCO2 values are associated with better prognosis.”
BackgroundResult
Cited by
Deakin, C. D., Nolan, J. P., Soar, J., Sunde, K., Koster, R. W., Smith, G. B., & Perkins, G. D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.017 · Cited by 2,700
Kleinman, M. E., Chameides, L., Schexnayder, S. M., Samson, R. A., Hazinski, M. F., Atkins, D. L., Berg, M. D., de Caen, A. R., Fink, E. L., Freid, E. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971101 · Cited by 1,949
Neumar, R. W., Otto, C. W., Link, M. S., Kronick, S. L., Shuster, M., Callaway, C. W., Kudenchuk, P. J., Ornato, J. P., McNally, B., Silvers, S. M., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970988 · Cited by 1,634
European Resuscitation Council Guidelines for Resuscitation 2015
Soar, J., Nolan, J. P., Böttiger, B. W., Perkins, G. D., Lott, C., Carli, P., Pellis, T., Sandroni, C., Skrifvars, M. B., Smith, G. B., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.016 · Cited by 1,503
European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive summary
Nolan, J. P., Soar, J., Zideman, D. A., Biarent, D., Bossaert, L. L., Deakin, C., Koster, R. W., Wyllie, J., & Böttiger, B. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.021 · Cited by 1,375
European Resuscitation Council Guidelines for Resuscitation 2015
Perkins, G. D., Handley, A. J., Koster, R. W., Castrén, M., Smyth, M. A., Olasveengen, T., Monsieurs, K. G., Raffay, V., Gräsner, J.-T., Wenzel, V., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.015 · Cited by 1,287
Soar, J., Berg, K. M., Andersen, L. W., Böttiger, B. W., Cacciola, S., Callaway, C. W., Couper, K., Cronberg, T., D’Arrigo, S., Deakin, C. D., et al. (2020) · Resuscitation · doi:10.1016/j.resuscitation.2020.09.012 · Cited by 616
Morrison, L. J., Deakin, C. D., Morley, P. T., Callaway, C. W., Kerber, R. E., Kronick, S. L., Lavonas, E. J., Link, M. S., Neumar, R. W., Otto, C. W., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971051 · Cited by 612
International Evidence-Based Recommendations for Focused Cardiac Ultrasound
Via, G., Hussain, A., Wells, M., Reardon, R., ElBarbary, M., Noble, V. E., Tsung, J. W., Neskovic, A. N., Price, S., Oren-Grinberg, A., et al. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.05.001 · Cited by 587
Breitkreutz, R., Walcher, F., & Seeger, F. H. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260626.23848.fc · Cited by 417
Berg, M. D., Schexnayder, S. M., Chameides, L., Terry, M., Donoghue, A., Hickey, R. W., Berg, R. A., Sutton, R. M., & Hazinski, M. F. (2010) · Pediatrics · doi:10.1542/peds.2010-2972c · Cited by 398
Emergency department point-of-care ultrasound in out-of-hospital and in-ED cardiac arrest
Gaspari, R., Weekes, A., Adhikari, S., Noble, V. E., Nomura, J. T., Theodoro, D., Woo, M., Atkinson, P., Blehar, D., Brown, S. M., et al. (2016) · Resuscitation · doi:10.1016/j.resuscitation.2016.09.018 · Cited by 279
Deakin, C. D., Morrison, L. J., Morley, P. T., Callaway, C. W., Kerber, R. E., Kronick, S. L., Lavonas, E. J., Link, M. S., Neumar, R. W., Otto, C. W., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.027 · Cited by 203
Focus cardiac ultrasound: the European Association of Cardiovascular Imaging viewpoint
Neskovic, A. N., Edvardsen, T., Galderisi, M., Garbi, M., Gullace, G., Jurcut, R., Dalen, H., Hagendorff, A., Lancellotti, P., for the European Association of Cardiovascular Imaging Document Reviewers:, et al. (2014) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu081 · Cited by 202
“Studies have shown that these findings may beneficially modify patient management, 41 and predict outcome.(42,43,44,45,46) We believe that further expansion of the list of teaching and training targets for FoCUS (i.”
BackgroundBerg, K. M., Soar, J., Andersen, L. W., Böttiger, B. W., Cacciola, S., Callaway, C. W., Couper, K., Cronberg, T., D’Arrigo, S., Deakin, C. D., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000893 · Cited by 195
Pediatric emergency medicine point-of-care ultrasound: summary of the evidence
Marin, J. R., Abo, A. M., Arroyo, A. C., Doniger, S. J., Fischer, J. W., Rempell, R., Gary, B., Holmes, J. F., Kessler, D. O., Lam, S. H. F., et al. (2016) · Critical Ultrasound Journal · doi:10.1186/s13089-016-0049-5 · Cited by 190
Paiva, E. F., Paxton, J. H., & O’Neil, B. J. (2018) · Resuscitation · doi:10.1016/j.resuscitation.2017.12.003 · Cited by 172
T. Arntfield, R., & J. Millington, S. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801784952 · Cited by 164
“With respect to prognosis in particular, there have been several compelling and widely quoted articles which have demonstrated that the absence of cardiac motion at any stage of the resuscitative effort suggests no opportunity for return of spontaneous circulation [61-63].”
BackgroundKleinman, M. E., de Caen, A. R., Chameides, L., Atkins, D. L., Berg, R. A., Berg, M. D., Bhanji, F., Biarent, D., Bingham, R., Coovadia, A. H., et al. (2010) · Pediatrics · doi:10.1542/peds.2010-2972a · Cited by 86
Monitor the quality of cardiopulmonary resuscitation in 2020
Genbrugge, C., Eertmans, W., & Salcido, D. D. (2020) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000726 · Cited by 12
Metadata
- Authors
- Salen, P., O'Connor, R., Sierzenski, P., Passarello, B., Pancu, D., Melanson, S., Arcona, S., Reed, J., & Heller, M.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2001-06
- Volume
- 8
- Issue
- 6
- Pages
- 610-615
- ISSN
- 1069-6563 (ISSN-L)
- 1553-2712
- OpenAlex
- W2046402214
- Cited by
- 173
- References
- 6
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.