The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
End-Tidal Carbon Dioxide Concentration during Cardiopulmonary Resuscitation
Abstract
We prospectively measured the end-tidal carbon dioxide concentration during 13 episodes of cardiac arrest in 10 critically ill patients receiving mechanical ventilation, to evaluate its usefulness as an indicator of circulatory status during cardiac arrest and resuscitation. The end-tidal carbon dioxide concentration decreased from a mean (+/- SD) of 1.4 +/- 0.9 to 0.4 +/- 0.4 percent after the onset of cardiac arrest. During precordial compression, it increased to 1.0 +/- 0.5 percent. The decreases in the end-tidal carbon dioxide concentration were associated with increases in systemic oxygen extraction (r = 0.79). Spontaneous circulation was restored on seven occasions. This was heralded by a rapid increase in the end-tidal carbon dioxide concentration, from 1.3 +/- 0.5 percent to an overshoot value of 3.7 +/- 2.1 percent, within approximately 30 seconds. The concentration then declined to a stable value of 2.4 +/- 1.8 percent four minutes after resuscitation. However, it remained 0.7 +/- 0.4 percent in six patients in whom resuscitative efforts failed to restore spontaneous circulation. These observations are consistent with experimental studies of cardiopulmonary resuscitation in pigs, in which the end-tidal carbon dioxide concentration varied directly with the cardiac output produced by precordial compression. We therefore propose that measurement of the end-tidal carbon dioxide concentration may be a practical, non-invasive method for monitoring blood flow generated by precordial compression during cardiopulmonary resuscitation and an almost immediate indicator of successful resuscitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kouwenhoven, W. B. (1960) · JAMA · doi:10.1001/jama.1960.03020280004002 · Cited by 2,106
Lipowski, Z. J. (1974) · The Lancet · doi:10.1016/s0140-6736(74)92478-7 · Cited by 944
Difference in Acid-Base State between Venous and Arterial Blood during Cardiopulmonary Resuscitation
Weil, M. H., Rackow, E. C., Trevino, R., Grundler, W., Falk, J. L., & Griffel, M. I. (1986) · New England Journal of Medicine · doi:10.1056/nejm198607173150303 · Cited by 539
Self-citationExpired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation.
Gudipati, C. V., Weil, M. H., Bisera, J., Deshmukh, H. G., & Rackow, E. C. (1988) · Circulation · doi:10.1161/01.cir.77.1.234 · Cited by 329
Self-citationStandards and Guidelines for Cardiopulmonary Resuscitation (CPR) and Emergency Cardiac Care (ECC)
(1980) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1980.03310050017015 · Cited by 325
Arteriovenous carbon dioxide and pH gradients during cardiac arrest.
Grundler, W., Weil, M. H., & Rackow, E. C. (1986) · Circulation · doi:10.1161/01.cir.74.5.1071 · Cited by 188
Self-citationSodium bicarbonate administration during cardiac arrest. Effect on arterial pH PCO2, and osmolality.
Bishop, R. L., & Weisfeldt, M. L. (1976) · PubMed · Cited by 161
Sodium Bicarbonate Administration During Cardiac Arrest
Bishop, R. L. (1976) · JAMA · doi:10.1001/jama.1976.03260310020014 · Cited by 133
Acid-base determinants of survival after cardiopulmonary resuscitation
Weil, M. H., Ruiz, C. E., Michaels, S., et al. (1985) · Critical Care Medicine · doi:10.1097/00003246-198511000-00005 · Cited by 87
Self-citationAlveolar CO2 Measured by Expiration Into the Rapid Infrared Gas Analyzer
DuBois, A. B., Fowler, R. C., Soffer, A., & Fenn, W. O. (1952) · Journal of Applied Physiology · doi:10.1152/jappl.1952.4.7.526 · Cited by 87
Cited by
Neumar, R. W., Otto, C. W., Link, M. S., Kronick, S. L., Shuster, M., Callaway, C. W., Kudenchuk, P. J., Ornato, J. P., McNally, B., Silvers, S. M., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970988 · Cited by 1,634
European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive summary
Nolan, J. P., Soar, J., Zideman, D. A., Biarent, D., Bossaert, L. L., Deakin, C., Koster, R. W., Wyllie, J., & Böttiger, B. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.021 · Cited by 1,375
Cook, T. M., Woodall, N., Harper, J., & Benger, J. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer059 · Cited by 1,065
Cooper, D. J., Walley, K. R., Wiggs, B. R., & Russell, J. A. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-112-7-492 · Cited by 452
Comparison of three different methods to confirm tracheal tube placement in emergency intubation
Grmec, Š. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1290-x · Cited by 332
Metadata
- Authors
- Falk, J. L., Rackow, E. C., & Weil, M. H.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1988-03-10
- Volume
- 318
- Issue
- 10
- Pages
- 607-611
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2338781165
- Cited by
- 466
- References
- 10
- FWCI
- 27.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: End-Tidal Carbon Dioxide Concentration during Cardiopulmonary Resuscitation. https://app.cochat.ai/papers/10.1056/nejm198803103181005
- The paper
- Falk, J. L., Rackow, E. C., & Weil, M. H. (1988). End-Tidal Carbon Dioxide Concentration during Cardiopulmonary Resuscitation. New England Journal of Medicine. https://doi.org/10.1056/nejm198803103181005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.