The DOI matches its Crossref record.
Availability and Quality of Computed Tomography and Magnetic Resonance Imaging Equipment in U.S. Emergency Departments
Open accessAbstract
Objectives: The objective was to determine the availability and quality of computed tomography (CT) and magnetic resonance imaging (MRI) equipment in U.S. emergency departments (EDs). The authors hypothesized that smaller, rural EDs have less availability and lower‐quality equipment. Methods: This was a random selection of 262 (5%) U.S. EDs from the 2005 National Emergency Department Inventories (NEDI)‐USA (http://www.emnet‐usa.org/). The authors telephoned radiology technicians about the presence of CT and MRI equipment, availability for ED imaging, and number of slices for the available CT scanners. The analysis was stratified by site characteristics. Results: The authors collected data from 260 institutions (99% response). In this random sample of EDs, the median annual patient visit volume was 19,872 (interquartile range = 6,788 to 35,757), 28% (95% confidence interval [CI] = 22% to 33%) were rural, and 27% (95% CI = 21% to 32%) participated in the Critical Access Hospital program. CT scanners were present in 249 (96%) institutions, and of these, 235 (94%) had 24/7 access for ED patients. CT scanner resolution varied: 28% had 1–4 slice, 33% had 5–16 slice, and 39% had a more than 16 slice. On‐site MRI was available for 171 (66%) institutions, and mobile MRI for 53 (20%). Smaller, rural, and critical access hospitals had lower CT and MRI availability and less access to higher‐resolution CT scanners. Conclusions: Although access to CT imaging was high (>90%), CT resolution and access to MRI were variable. Based on observed differences, the availability and quality of imaging equipment may vary by ED size and location.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sacco, R. L., Kasner, S. E., Broderick, J. P., Caplan, L. R., Connors, J. J. (., Culebras, A., Elkind, M. S. V., George, M. G., Hamdan, A. D., Higashida, R. T., et al. (2013) · Stroke · doi:10.1161/str.0b013e318296aeca · Cited by 3,569
Low‐field MRI: Clinical promise and challenges
Arnold, T. C., Freeman, C. W., Litt, B., & Stein, J. M. (2023) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28408 · Cited by 374
Computed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335
Claessens, Y.-E., Debray, M.-P., Tubach, F., Brun, A.-L., Rammaert, B., Hausfater, P., Naccache, J.-M., Ray, P., Choquet, C., Carette, M.-F., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201501-0017oc · Cited by 322
Valente, A. M., Cook, S., Festa, P., Ko, H. H., Krishnamurthy, R., Taylor, A. M., Warnes, C. A., Kreutzer, J., & Geva, T. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.11.009 · Cited by 317
Metadata
- Authors
- Ginde, A. A., Foianini, A., Renner, D. M., Valley, M., & Camargo, Jr.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2008-08
- Volume
- 15
- Issue
- 8
- Pages
- 780-783
- ISSN
- 1069-6563 (ISSN-L)
- 1553-2712
- OpenAlex
- W2088139330
- Cited by
- 197
- References
- 0
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Availability and Quality of Computed Tomography and Magnetic Resonance Imaging Equipment in U.S. Emergency Departments. https://app.cochat.ai/papers/10.1111/j.1553-2712.2008.00192.x
- The paper
- Ginde, A. A., Foianini, A., Renner, D. M., Valley, M., & Camargo, Jr. (2008). Availability and Quality of Computed Tomography and Magnetic Resonance Imaging Equipment in U.S. Emergency Departments. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2008.00192.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.