The DOI matches its Crossref record.
Comparison of Celox-A, ChitoFlex, WoundStat, and Combat Gauze Hemostatic Agents Versus Standard Gauze Dressing in Control of Hemorrhage in a Swine Model of Penetrating Trauma: HEMOSTATIC AGENTS VS. STANDARD GAUZE FOR HEMORRHAGE CONTROL IN SWINE
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The hemostatic mechanism exerted is based on the action exerted by chitosan on red blood cells and platelets, which, through cross-linking, leads to the formation of a mucoadhesive physical barrier around the site of bleeding [45].”
From Chitosan Hemostatic Dressings: Properties and Surgical Applications (2024) · cites this paper as [45]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 30
- Acosta, 1998, Lethal injuries and time to death in a level one trauma center, J Am Coll Surg., 186, 528, 10.1016/S1072-7515(98)00082-9 · DOI · Paper page
- Sauaia, 1995, Epidemiology of trauma deaths: a reassessment, J Trauma., 38, 185, 10.1097/00005373-199502000-00006 · DOI · Paper page
- Kauvar, 2006, Impact of hemorrhage on trauma outcome: an overview of epidemiology, clinical presentations, and therapeutic considerations, J Trauma., 60, S3, 10.1097/01.ta.0000199961.02677.19 · DOI · Paper page
- Malone, 2003, Blood transfusion, independent of shock severity, is associated with worse outcome in trauma, J Trauma., 54, 898, 10.1097/01.TA.0000060261.10597.5C · DOI · Paper page
- Rhee, 2008, Quikclot use in trauma for hemorrhage control: case series of 103 documented uses, J Trauma., 64, 1093, 10.1097/TA.0b013e31812f6dbc · DOI · Paper page
- Wedmore, 2006, A special report on the chitosan-based hemostatic dressing: experience in current combat operations, J Trauma., 60, 655, 10.1097/01.ta.0000199392.91772.44 · DOI · Paper page
- Brown, 2009, Experience with chitosan dressings in a civilian EMS system, J Emerg Med., 37, 1, 10.1016/j.jemermed.2007.05.043 · DOI · Paper page
- Alam, 2003, Comparative analysis of hemostatic agents in a swine model of lethal groin injury, J Trauma., 54, 1077, 10.1097/01.TA.0000068258.99048.70 · doi:10.1097/01.ta.0000068258.99048.70
- Alam, 2004, Application of a zeolite hemostatic agent achieves 100% survival in a lethal model of complex groin injury in swine, J Trauma., 56, 974, 10.1097/01.TA.0000127763.90890.31 · doi:10.1097/01.ta.0000127763.90890.31
- Ward, 2007, Comparison of a new hemostatic agent to current combat hemostatic agents in a swine model of lethal extremity arterial hemorrhage, J Trauma., 63, 276, 10.1097/TA.0b013e3180eea8a5 · DOI
- Ahuja, 2006, Testing of modified zeolite hemostatic dressings in a large animal model of lethal groin injury, J Trauma., 61, 1312, 10.1097/01.ta.0000240597.42420.8f · doi:10.1097/01.ta.0000240597.42420.8f
- Kozen, 2008, An alternative hemostatic dressing: comparison of CELOX, Hemcon, and QuikClot, Acad Emerg Med., 15, 74, 10.1111/j.1553-2712.2007.00009.x · DOI · Paper page
- Sambasivan, 2009, A highly porous silica and chitosan-based dressing is superior in controlling hemorrhage in a severe groin injury model in swine, Am J Surg., 197, 576, 10.1016/j.amjsurg.2008.12.011 · doi:10.1016/j.amjsurg.2008.12.011
- Acheson, 2005, Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhages in swine, J Trauma., 59, 865, 10.1097/01.ta.0000187655.63698.9f · doi:10.1097/01.ta.0000187655.63698.9f
- Kheirabadi, 2009, Comparison of new hemostatic granules/powders with currently deployed hemostatic products in a lethal model of extremity arterial hemorrhage in swine, J Trauma., 66, 316, 10.1097/TA.0b013e31819634a1 · DOI
- Arnaud, 2009, Comparison of 10 hemostatic dressings in a groin transection model in swine, J Trauma., 67, 848, 10.1097/TA.0b013e3181b2897f · doi:10.1097/ta.0b013e3181b2897f
- Arnaud, 2009, Comparison of 10 hemostatic dressings in a groin puncture model in swine, J Vasc Surg., 3, 632, 10.1016/j.jvs.2009.06.010 · doi:10.1016/j.jvs.2009.06.010
- Carraway, 2008, Comparison of a new mineral based hemostatic agent to a commercially available granular zeolite agent for hemostasis in a swine model of lethal extremity arterial hemorrhage, Resuscitation., 78, 230, 10.1016/j.resuscitation.2008.02.019 · DOI
- Devlin, 2009, Comparison of Chitoflex, CELOX, and Quikclot in control of hemorrhage, J Emerg Med., 10.1016/j.jemermed.2009.02.017 · doi:10.1016/j.jemermed.2009.02.017
- Dorlac, 2005, Mortality from isolated civilian penetrating extremity injury, J Trauma., 59, 217, 10.1097/01.TA.0000173699.71652.BA · doi:10.1097/01.ta.0000173699.71652.ba
- Institute of Laboratory Animal Resources, National Research Council, 1996, Guide for the Care and Use of Laboratory Animals
- Kheirabadi, 2009, Determination of efficacy of new hemostatic dressings in a model of extremity arterial hemorrhage in swine, J Trauma., 67, 450, 10.1097/TA.0b013e3181ac0c99 · DOI
- Gustafson, 2007, Chitosan dressing provides hemostasis in swine femoral arterial injury model, Prehosp Emerg Care., 11, 172, 10.1080/10903120701205893 · DOI
- Pusateri, 2003, Effect of a chitosan-based hemostatic dressing on blood loss and survival in a model of severe venous hemorrhage and hepatic injury in swine, J Trauma., 54, 177, 10.1097/00005373-200301000-00023 · DOI · Paper page
- Kheirabadi, 2005, Hemostatic efficacy of two advanced dressings in an aortic hemorrhage model in swine, J Trauma., 59, 25, 10.1097/01.TA.0000171458.72037.EE · doi:10.1097/01.ta.0000171458.72037.ee
- Kheirabadi BS Safety and efficacy updates of new hemostatic products. Oral presentation at the Special Operations Medical Association Annual Conference
- Devlin, 2009, Models for hemostatic agent testing: control versus fidelity, J Trauma., 67, 677, 10.1097/TA.0b013e3181b01f40 · doi:10.1097/ta.0b013e3181b01f40
- Devlin, 2009, Swine models of hemorrhagic shock: to splenectomize or not to splenectomize, that is the question, J Trauma., 67, 895, 10.1097/TA.0b013e3181b837ab · doi:10.1097/ta.0b013e3181b837ab
- National Association of Emergency Medical Technicians, 2007, Prehospital Trauma Life Support: Military Version
- Treib, 1999, An international view of hydroxyethyl starches, Intensive Care Med., 25, 258, 10.1007/s001340050833 · doi:10.1007/s001340050833
Cited by
Chitosan Hemostatic Dressings: Properties and Surgical Applications
Cassano, R., Perri, P., Scarcello, E., Piro, P., Sole, R., Curcio, F., & Trombino, S. (2024) · Polymers · doi:10.3390/polym16131770 · Cited by 77
Metadata
- Authors
- Littlejohn, L. F., Devlin, J. J., Kircher, S. S., Lueken, R., Melia, M. R., & Johnson, A. S.
- Venue
- Academic Emergency Medicine
- Publisher
- Wiley
- Published
- 2011-04
- Volume
- 18
- Issue
- 4
- Pages
- 340-350
- ISSN
- 1069-6563
- Cited by
- 116
- References
- 0
- Language
- en
- Licence
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm, 1614 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Celox-A, ChitoFlex, WoundStat, and Combat Gauze Hemostatic Agents Versus Standard Gauze Dressing in Control of Hemorrhage in a Swine Model of Penetrating Trauma: HEMOSTATIC AGENTS VS. STANDARD GAUZE FOR HEMORRHAGE CONTROL IN SWINE. https://app.cochat.ai/papers/10.1111/j.1553-2712.2011.01036.x
- The paper
- Littlejohn, L. F., Devlin, J. J., Kircher, S. S., Lueken, R., Melia, M. R., & Johnson, A. S. (2011). Comparison of Celox-A, ChitoFlex, WoundStat, and Combat Gauze Hemostatic Agents Versus Standard Gauze Dressing in Control of Hemorrhage in a Swine Model of Penetrating Trauma: HEMOSTATIC AGENTS VS. STANDARD GAUZE FOR HEMORRHAGE CONTROL IN SWINE. Academic Emergency Medicine. https://doi.org/10.1111/j.1553-2712.2011.01036.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.