CLINICAL METHOD FOR ELECTRICAL AND MECHANICAL RECORDING OF THE MECHANICALLY AND ELECTRICALLY ELICITED ANKLE REFLEX
The DOI matches its Crossref record.
Abstract
A method for quantitative evaluation of the ankle stretch reflex in man has been developed. The method includes recording of the mechanical and electrical stimulus intensity and of the electrical and mechanical reflex response. In addition, it offers the possibility of reflex latency recording. The size of the tendon tap was recorded by a reflex hammer incorporating an accelerometer which converts the retardation force, experienced by the hammer head when it strikes the tendon, to an electrical signal. The output signal has a linear relationship with the moment of force imposed upon the tendon-muscle system by the tap and can therefore be used as an indicator of muscle stretch. The strength of the electrical stimulus was estimated in milliamperes by the voltage drop across a serial resistor in the stimulating circuit. The electrical reflex response was recorded by surface electrodes over the triceps surae muscle, and the best recording electrode placement was determined. The reflex contraction was recorded by a general purpose myograph allowing isotonic as well as isometric recordings. The method described is easy to use, is not painful to the patient, and offers considerable precision and accuracy in ankle reflex recording.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tendon reflex variability and method of stimulation
Stam, J., & Tan, K. M. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90010-1 · Cited by 64
Measurement of tendon reflexes by surface electromyography in normal subjects
Stam, J., & van Crevel, H. (1989) · Journal of Neurology · doi:10.1007/bf00314505 · Cited by 51
“An S-shaped stimulus response (S-R) relation has been described previously in human subjects with tendon taps as stimuli [7].”
Reliability of the clinical and electromyographic examination of tendon reflexes
Stam, J., & Crevel, H. (1990) · Journal of Neurology · doi:10.1007/bf00314735 · Cited by 46
“The validity of SEMG recording of tendon reflexes has been examined by comparing it with mechanical measuring techniques [4, 7, 14], but to our knowledge neither method has been compared with clinical assessment of the reflexes.”
MethodOgawa, Y., Hirata, M., Okayama, A., Ichikawa, Y. E., & Goto, S. (1993) · Occupational and Environmental Medicine · doi:10.1136/oem.50.3.229 · Cited by 7
Metadata
- Authors
- Dietrichson, P., & Sørbye, R.
- Venue
- Acta Neurologica Scandinavica
- Publisher
- Hindawi Limited
- Published
- 1971-03
- Volume
- 47
- Issue
- 1
- Pages
- 1-21
- ISSN
- 0001-6314 (ISSN-L)
- 1600-0404
- OpenAlex
- W2057312183
- Cited by
- 51
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CLINICAL METHOD FOR ELECTRICAL AND MECHANICAL RECORDING OF THE MECHANICALLY AND ELECTRICALLY ELICITED ANKLE REFLEX. https://app.cochat.ai/papers/10.1111/j.1600-0404.1971.tb07461.x
- The paper
- Dietrichson, P., & Sørbye, R. (1971). CLINICAL METHOD FOR ELECTRICAL AND MECHANICAL RECORDING OF THE MECHANICALLY AND ELECTRICALLY ELICITED ANKLE REFLEX. Acta Neurologica Scandinavica. https://doi.org/10.1111/j.1600-0404.1971.tb07461.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.