The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
On the ocular refractive components: the Reykjavik Eye Study
Abstract
Abstract.: Purpose: To study the correlation between ocular refraction and the refractive components (corneal power, lens power and axial length) in a population‐based sample of normal subjects. Methods: We analysed the refractive and biometric findings for 723 right eyes (325 males and 398 females) comprising a population‐based random sample of citizens 55 years and older participating in the Reykjavik Eye Study. Measurements of refraction, corneal curvature (by keratometry), anterior chamber depth, lens thickness and axial length (all by ultrasound biometry) were used to calculate crystalline lens power. The correlation and regression between refraction and ocular refractive components (corneal power, anterior chamber depth, lens power and axial length) were studied by distributional statistical methods. Results: Refraction (spherical equivalent) showed a significant negative correlation with axial length (r = –0.59, P < 0.0001), lens power (r = –0.26, P < 0.0001) and corneal power (r = –0.16, P < 0.0001). There were significant negative correlations between axial length and corneal power (r = –0.44, P < 0.0001) and between axial length and lens power (r = –0.44, P < 0.0001). Based on multiple linear regression analysis, refraction could be correlated with corneal power, lens power and axial length in combination with a correlation coefficient of 0.98 (P < 0.0001). Conclusion: This study confirms that ocular refraction is statistically significantly correlated with not only axial length but also lens power and (to a lesser extent) corneal power. The variation and correlations of crystalline lens power were considerable – possibly indicating this component's modulatory effect on ocular refraction during growth. We conclude the refractive error of the eye to be a multifactorial condition involving a complex interplay between the cornea, the lens and the length of the eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Prevalence of Age-Related Maculopathy in Iceland: Reykjavik Eye Study
Jonasson, F. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.3.379 · Cited by 106
5-year incidence of age-related maculopathy in the Reykjavik Eye Study
JONASSON, F., ARNARSSON, A., PETO, T., SASAKI, H., SASAKI, K., & BIRD, A. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2004.07.020 · Cited by 64
Self-citation
Metadata
- Authors
- Olsen, T., Arnarsson, A., Sasaki, H., Sasaki, K., & Jonasson, F.
- Venue
- Acta Ophthalmologica Scandinavica
- Publisher
- Wiley
- Published
- 2007-02-07
- Volume
- 85
- Issue
- 4
- Pages
- 361-366
- ISSN
- 1395-3907 (ISSN-L)
- 1600-0420
- OpenAlex
- W2012445740
- Cited by
- 168
- References
- 2
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the ocular refractive components: the Reykjavik Eye Study. https://app.cochat.ai/papers/10.1111/j.1600-0420.2006.00847.x
- The paper
- Olsen, T., Arnarsson, A., Sasaki, H., Sasaki, K., & Jonasson, F. (2007). On the ocular refractive components: the Reykjavik Eye Study. Acta Ophthalmologica Scandinavica. https://doi.org/10.1111/j.1600-0420.2006.00847.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.