Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 344

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Effect of implant design on survival and success rates of titanium oral implants: a 10‐year prospective cohort study of the ITI® Dental Implant System

Karoussis, Ioannis K., Brägger, Urs, Salvi, Giovanni E., Bürgin, Walter, Lang, Niklaus P.·2004·Clinical Oral Implants Research

Abstract

Aim: The aim of this 10‐year study (observation time 8–12 years, mean: 10 years) was to compare the survival rates, success rates and incidences of biological complications using three different implant designs of the ITI® Dental Implant System. Material and methods: In 89 dental patients treated comprehensively, a total of 112 hollow screw (HS), 49 hollow cylinder (HC) and 18 angulated hollow cylinder (AHC) implants were installed depending on the available bone volume and according to prosthetic needs. One and 10 years after surgical placement, clinical and radiographic parameters were assessed. The incidences of peri‐implantitis according to various thresholds were registered over 10 years of maintenance. Results: Success criteria at 10 years were set at: pocket probing depth (PPD)5 mm, bleeding on probing (BoP)−, bone loss < 0.2 mm annually. The survival rate for HS was 95.4%, for HC 85.7% and for AHC 91.7%. Ninety percent of all the HS, 71% of the HC and 88% of the AHC did not present with an incidence of peri‐implantitis over the 10 years, HC having significantly higher incidence of peri‐implantitis than HS (P< 0.004). With the success criteria set above, a success rate for HS of 74%, for HC of 63% and for AHC of 61% was identified at 10 years. However, including a definition of PPD6 mm, BoP − and bone loss < 0.2 mm annually for success, the rates for HS were 78%, for HC 65% and for AHC 67%, respectively. Basing success criteria purely on clinical parameters (without radiographic analysis), such as: PPD5 mm and BoP−, the success rates increased to 90%, 76% and 89%, respectively. With PPD6 mm and BoP – as success criteria chosen, the respective rates were 94%, 82% and 94% for HS, HC and AHC implants, respectively. Conclusions: A significantly higher survival rate as well as a significantly lower incidence of peri‐implantitis was identified for hollow screw design ITI® Dental Implants after 10 years of service when compared to hollow cylinder design ITI® Dental Implants (95.4% vs. 85.7%; 10% vs. 29%). Depending on the setting of the threshold criteria for success, success rates are highly variable and hence, reporting of success rates with elaboration on the criteria set appears crucial for comparison of different studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2004.00983.x

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 344

Metadata

Authors
Karoussis, I. K., Brägger, U., Salvi, G. E., Bürgin, W., & Lang, N. P.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2004-01-20
Volume
15
Issue
1
Pages
8-17
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2162966368
Cited by
344
References
32
FWCI
12.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of implant design on survival and success rates of titanium oral implants: a 10‐year prospective cohort study of the ITI® Dental Implant System. https://app.cochat.ai/papers/10.1111/j.1600-0501.2004.00983.x
The paper
Karoussis, I. K., Brägger, U., Salvi, G. E., Bürgin, W., & Lang, N. P. (2004). Effect of implant design on survival and success rates of titanium oral implants: a 10‐year prospective cohort study of the ITI® Dental Implant System. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2004.00983.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.