Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Stimulating effect of implant loading on surrounding bone: Comparison of three numerical models and validation by in vivo data

Open access
Mellal, A., Wiskott, H. W. A., Botsis, J., Scherrer, S. S., Belser, U. C.·2004·Clinical Oral Implants Research

Abstract

Abstract: A number of algorithms have been proposed to model the adaptive behavior of bone under load. However, the predictions of several models have neither been compared nor have they been systematically related to in vivo data. To this end, the stress states of loaded implant–bone interfaces were analyzed before and after osseointegration using finite element (FE) techniques. In a preliminary step, an FE mesh of a cylindrical implant encased in a cancellous core surrounded by a cortical layer was constructed, and the stresses and strains that developed at the interface were determined. The implant was loaded with 100 N vertical and 30 N lateral loads. Using this structure, the peak compressive and tensile stresses were determined. Then bone remodeling predictions were assessed using three different models: von Mises equivalent strain, strain energy density and effective stress. Finally, a systematic search of the literature was conducted to relate the numerical predictions to existing in vivo data. The FE simulations led to the following conclusions: (1) calculated compressive stresses were lower than the ultimate compressive stresses of cortical and cancellous bone. (2) Calculated tensile stresses were generally superior to experimental data on the tensile strength of the bone–implant interface. (3) With one exception, the predictions of all models were homogeneously grouped on the stimulus scales. (4) The predictions of the models as to bone gain or loss were not consistent and at times contradictory. It is hypothesized that this effect is linked to a lazy zone that is too narrow. With respect to the application of the numerical models to in vivo data, peak strains and strain energy densities were consistent with in vivo data. No in vivo data were found that supported effective stress as a stimulus.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2004.01000.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 244

Metadata

Authors
Mellal, A., Wiskott, H. W. A., Botsis, J., Scherrer, S. S., & Belser, U. C.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2004-03-08
Volume
15
Issue
2
Pages
239-248
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W1982565494
Cited by
244
References
2
FWCI
3.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stimulating effect of implant loading on surrounding bone: Comparison of three numerical models and validation by in vivo data. https://app.cochat.ai/papers/10.1111/j.1600-0501.2004.01000.x
The paper
Mellal, A., Wiskott, H. W. A., Botsis, J., Scherrer, S. S., & Belser, U. C. (2004). Stimulating effect of implant loading on surrounding bone: Comparison of three numerical models and validation by in vivo data. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2004.01000.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.