Stimulating effect of implant loading on surrounding bone: Comparison of three numerical models and validation by in vivo data
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
A number of algorithms have been proposed to model the adaptive behavior of bone under load. However, the predictions of several models have neither been compared nor have they been systematically related to in vivo data. To this end, the stress states of loaded implant–bone interfaces were analyzed before and after osseointegration using finite element (FE) techniques. In a preliminary step, an FE mesh of a cylindrical implant encased in a cancellous core surrounded by a cortical layer was constructed, and the stresses and strains that developed at the interface were determined. The implant was loaded with 100 N vertical and 30 N lateral loads. Using this structure, the peak compressive and tensile stresses were determined. Then bone remodeling predictions were assessed using three different models: von Mises equivalent strain, strain energy density and effective stress. Finally, a systematic search of the literature was conducted to relate the numerical predictions to existing in vivo data. The FE simulations led to the following conclusions: (1) calculated compressive stresses were lower than the ultimate compressive stresses of cortical and cancellous bone. (2) Calculated tensile stresses were generally superior to experimental data on the tensile strength of the bone–implant interface. (3) With one exception, the predictions of all models were homogeneously grouped on the stimulus scales. (4) The predictions of the models as to bone gain or loss were not consistent and at times contradictory. It is hypothesized that this effect is linked to a lazy zone that is too narrow. With respect to the application of the numerical models to in vivo data, peak strains and strain energy densities were consistent with in vivo data. No in vivo data were found that supported effective stress as a stimulus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Das Gesetz der Transformation der Knochen
Wolff, J. (1893) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/s-0028-1144106 · Cited by 1,999
Regulation of bone formation by applied dynamic loads.
Rubin, C. T., & Lanyon, L. E. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00012 · Cited by 1,558
Regulation of bone mass by mechanical strain magnitude
Rubin, C. T., & Lanyon, L. E. (1985) · Calcified Tissue International · doi:10.1007/bf02553711 · Cited by 1,294
Effects of mechanical forces on maintenance and adaptation of form in trabecular bone
Huiskes, R., Ruimerman, R., van Lenthe, G. H., & Janssen, J. D. (2000) · Nature · doi:10.1038/35015116 · Cited by 1,180 · cited 1×
“Most recently, Huiskes and coworkers presented a model that related the applied stresses to the morphological adaptation of the bone’s trabecular architecture (Huiskes et al. 2000; Ruimerman et al. 2001).”
BackgroundAdaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians.
Frost, H. M. (1994) · PubMed · doi:10.1043/0003-3219(1994)064<0175:wlabsa>2.0.co;2 · Cited by 839 · cited 2×
“The stimulus window [e0 min e0 max] was taken from previously published experimental data and set to 100–2000 mm/m (Frost 1994; Wiskott & Belser 1999).”
BackgroundMethodClaes, L. E., & Heigele, C. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00153-5 · Cited by 802 · cited 1×
“Frost (1964) suggested a trigger criterion for remodeling based on strain magnitude.”
BackgroundMechanobiology of Skeletal Regeneration
Carter, D. R., Beaupr??, G. S., Giori, N. J., & Helms, J. A. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00006 · Cited by 758
Bone remodeling I: theory of adaptive elasticity
Cowin, S. C., & Hegedus, D. H. (1976) · Journal of Elasticity · doi:10.1007/bf00041724 · Cited by 665
Pauwels, F. (1980) · Springer eBooks · doi:10.1007/978-3-642-67138-8 · Cited by 643 · cited 1×
“During numerical analyses, bone apposition and resorption were treated with respect to a ‘stimulus window’ as adapted from Rong et al. (2001) and correlated to experimental evidence (Frost 1994):”
Method
Cited by
Stress shielding and fatigue limits of poly‐ether‐ether‐ketone dental implants
Lee, W., Koak, J., Lim, Y., Kim, S., Kwon, H., & Kim, M. (2012) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.32669 · Cited by 268
Dental implant induced bone remodeling and associated algorithms
Lin, D., Li, Q., Li, W., & Swain, M. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.11.007 · Cited by 194
Occlusal overload and bone/implant loss
Naert, I., Duyck, J., & Vandamme, K. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02550.x · Cited by 181
“…be defined at the outer bone surface e.g. through strain gauge technology, and even at the implant-bone interface through numerical modelling, the stress and strain evoked at the implant-bone interface remain impossible to be quantified today in the animal/clinical settings (Mellal et al. 2004).”
BackgroundInfluentialYao, J., Wen, C. Y., Zhang, M., Cheung, J. T.-M., Yan, C., Chiu, K.-Y., Lu, W. W., & Fan, Y. (2014) · International Orthopaedics · doi:10.1007/s00264-014-2290-5 · Cited by 20
Xiao, Y., Liang, Z., Shen, S., Liu, F., Hu, H., & Chen, B. (2023) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-023-00677-x · Cited by 10
Metadata
- Authors
- Mellal, A., Wiskott, H. W. A., Botsis, J., Scherrer, S. S., & Belser, U. C.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2004-03-08
- Volume
- 15
- Issue
- 2
- Pages
- 239-248
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1982565494
- Cited by
- 244
- References
- 45
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.