Comparison of osteoblast spreading on microstructured dental implant surfaces and cell behaviour in an explant model of osseointegration: A scanning electron microscopic study
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Objectives: To compare interactions between rat calvarial osteoblasts and titanium dental implants with different microstructured surfaces. Material and methods: Seven commercially available implants were used. Surfaces included plasma‐sprayed, grit‐blasted and/or acid‐etched, smooth‐machined and anodised titanium. Two methods were used to compare cell behaviour: (1) A cell‐spreading assay in which percentages of cells at four different stages of attachment were identified by scanning electron microscopy and quantified within a 30 min attachment period. (2) Implants were placed in ‘pocket culture’ within nylon mesh sacs in contact with explanted calvarial bone fragments for 2 and 4 weeks. Results: Surfaces combining grit blasting and acid etching, of microporous topography, showed significantly enhanced rates of cell spreading in comparison with the others. Differential cell morphology was observed in both suspension assays and pocket cultures. In the latter, cells migrated onto all surfaces. Multicellular layers with extracellular matrix (ECM) were present between the layers and on the material surfaces after 2 weeks. After 4 weeks, cell layers were more consolidated, and microstructures were obscured by layers of cells and ECM. Mineralised tissue was seen in association with ECM on grit‐blasted surfaces of rough and smooth microtopography. Conclusions: The two methods provided complementary information: a rough surface of porous microstructure may enhance the rate of cell spreading. Differentiation and calcification occurred on surfaces of both rough and smooth microstructure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500 · cited 4×
“Reassembly of this protein in focal contacts is a prerequisite of osteoblast attachment in vitro (Meyer et al. 1998; Anselme 2000 ).”
BackgroundInfluentialMineralized bone nodules formedin vitro from enzymatically released rat calvaria cell populations
Bellows, C. G., Aubin, J. E., Heersche, J. N. M., & Antosz, M. E. (1986) · Calcified Tissue International · doi:10.1007/bf02556874 · Cited by 846
Effects of topography and composition of titanium surface oxides on osteoblast responses
Zhu, X., Chen, J., Scheideler, L., Reichl, R., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.011 · Cited by 534 · cited 1×
“By quantifying the percentages of attached cells at each of these stages, Lumbikanonda & Sammons (2001) showed that spreading occurred faster on titanium plasma-sprayed surfaces compared with smooth- or grit-blasted surfaces, while Zhu et al. (2004) showed differential percentages of fully spread cells on titanium oxi…”
BackgroundSuggested guidelines for the topographic evaluation of implant surfaces.
Wennerberg, A., & Albrektsson, T. O. (2000) · PubMed · Cited by 462
Oral implant surfaces: Part 2--review focusing on clinical knowledge of different surfaces.
Albrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 443
Underlying mechanisms at the bone–biomaterial interface.
Schwartz, Z., & Boyan, B. D. (1994) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240560310 · Cited by 397
Roughness induced dynamic changes of wettability of acid etched titanium implant modifications
Rupp, F., Scheideler, L., Rehbein, D., Axmann, D., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.015 · Cited by 355 · cited 2×
“been shown to enhance fibrin and SAOS-2 cell adhesion and to promote cell proliferation (Scheideler et al. 2003) in comparison with DPS, thus demonstrating further biological consequences of the alterations in surface properties because of the differential acid etching conditions ( Rupp et al. 2004 ).”
BackgroundThe Role of Implant Surface Characteristics in the Healing of Bone
Kieswetter, K., Schwartz, Z., Dean, D. D., & Boyan, B. D. (1996) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411960070040301 · Cited by 338 · cited 1×
“Initial interactions between implant surfaces, proteins and, subsequently cells, in the early stages of healing are believed to predetermine later events in the process of osseointegration of dental implants (Schwartz & Boyan 1994; Kieswetter et al. 1996 ).”
BackgroundDept. of Biomedical Engineering, G. I. O. T., Boyan, B., Lossdörfer, S., Wang, L., Zhao, G., Lohmann, C., Cochran, D., & Schwartz, Z. (2003) · European Cells and Materials · doi:10.22203/ecm.v006a03 · Cited by 309
Schwartz, Z., Lohmann, C. H., Oefinger, J., Bonewald, L. F., Dean, D. D., & Boyan, B. D. (1999) · Advances in Dental Research · doi:10.1177/08959374990130011301 · Cited by 308
A scanning electron microscope study of cell adhesion and spreading in vitro
Rajaraman, R., Rounds, D. E., Yen, S. P. S., & Rembaum, A. (1974) · Experimental Cell Research · doi:10.1016/0014-4827(74)90248-1 · Cited by 278 · cited 2×
“Cells were classified according to four stages of cell attachment ( Rajaraman et al. 1974 ): numbers were expressed as percentages of the total number of cells counted on each implant.”
BackgroundOsteoblast-Mediated Mineral Deposition in Culture is Dependent on Surface Microtopography
Boyan, B. D., Bonewald, L. F., Paschalis, E. P., Lohmann, C. H., Rosser, J., Cochran, D. L., Dean, D. D., Schwartz, Z., & Boskey, A. L. (2002) · Calcified Tissue International · doi:10.1007/s00223-001-1114-y · Cited by 256
Massaro, C., Rotolo, P., De Riccardis, F., Milella, E., Napoli, A., Wieland, M., Textor, M., Spencer, N. D., & Brunette, D. M. (2002) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1015170625506 · Cited by 216 · cited 1×
“Below this, the acid-etched Osseotite surface (described by Massaro et al. 2002 ) consists of sharp, pointed 5–10mm long, ridges, frequently in radiating parallel lines, 1–2 mm in height, forming V-shaped valleys and 1–2mm diameter pores (Fig. 1f).”
MethodHowlett, C. R., Evans, M. D. M., Walsh, W. R., Johnson, G., & Steele, J. G. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90070-1 · Cited by 178
Bone Cell Expression on Titanium Surfaces is Altered by Sterilization Treatments
Stanford, C. M., Keller, J. C., & Solursh, M. (1994) · Journal of Dental Research · doi:10.1177/00220345940730050801 · Cited by 137
Vezeau, P. J., Gf, K., Draughn, R. A., & Keller, J. C. (1996) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(96)90694-1 · Cited by 109 · cited 1×
“While most studies have been performed using model surfaces, these cannot perfectly simulate the surfaces of implants as prepared for clinical use, as they may be affected by post-manufacture processes such as sterilisation and packaging (Stanford et al. 1994; Vezeau et al. 1996 ).”
BackgroundThe Titanium-Bone Cell Interface In Vitro: The Role of the Surface in Promoting Osteointegration
Boyan, B. D., Dean, D. D., Lohmann, C. H., Cochran, D. L., Sylvia, V. L., & Schwartz, Z. (2001) · Engineering materials · doi:10.1007/978-3-642-56486-4_17 · Cited by 82
Principles of Cell Behavior on Titanium Surfaces and Their Application to Implanted Devices
Brunette, D. M. (2001) · Engineering materials · doi:10.1007/978-3-642-56486-4_15 · Cited by 79
Papalexiou, V., Novaes, A. B., Grisi, M. F. M., Souza, S. S. L. S., Taba, M., & Kajiwara, J. K. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.00995.x · Cited by 75
Cellular and molecular biological events at the implant interface
Bagambisa, F. B., Kappert, H. F., & Schilli, W. (1994) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/s1010-5182(05)80290-2 · Cited by 49 · cited 1×
“In vitro studies have shown that osteoblasts adhere to artificial surfaces via the interaction between cell membrane integrins and specific adhesion proteins present in serum, such as fibronectin and vitronectin, or proteins produced by the cells themselves, such as osteopontin, which rapidly adsorb to the material su…”
BackgroundMeyer, U., Meyer, T., & Jones, D. B. (1998) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008894612021 · Cited by 37 · cited 2×
“Reassembly of this protein in focal contacts is a prerequisite of osteoblast attachment in vitro ( Meyer et al. 1998; Anselme 2000).”
Background
Cited by
Bacakova, L., Filova, E., Parizek, M., Ruml, T., & Svorcik, V. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.004 · Cited by 1,000
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Rosales-Leal, J. I., Rodríguez-Valverde, M. A., Mazzaglia, G., Ramón-Torregrosa, P. J., Díaz-Rodríguez, L., García-Martínez, O., Vallecillo-Capilla, M., Ruiz, C., & Cabrerizo-Vílchez, M. A. (2010) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2009.12.017 · Cited by 471
Bornstein, M. M., Valderrama, P., Jones, A. A., Wilson, T. G., Seibl, R., & Cochran, D. L. (2008) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01473.x · Cited by 234
Review of zirconia-based bioceramic: Surface modification and cellular response
Soon, G., Pingguan-Murphy, B., Lai, K. W., & Akbar, S. A. (2016) · Ceramics International · doi:10.1016/j.ceramint.2016.05.077 · Cited by 180
Metadata
- Authors
- Sammons, R. L., Lumbikanonda, N., Gross, M., & Cantzler, P.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2005-11-14
- Volume
- 16
- Issue
- 6
- Pages
- 657-666
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2136441104
- Cited by
- 169
- References
- 21
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.