Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 380

The DOI matches its Crossref record.

Are ceramic implants a viable alternative to titanium implants? A systematic literature review

Andreiotelli, Marina, Wenz, Hans J., Kohal, Ralf‐Joachim·2009·Clinical Oral Implants Research

Abstract

Aim: The aim of this systematic review was to screen the literature in order to locate animal and clinical data on bone–implant contact (BIC) and clinical survival/success that would help to answer the question ‘Are ceramic implants a viable alternative to titanium implants?’ Material and methods: A literature search was performed in the following databases: (1) the Cochrane Oral Health Group's Trials Register, (2) the Cochrane Central Register of Controlled Trials (CENTRAL), (3) MEDLINE (Ovid), and (4) PubMed. To evaluate biocompatibility, animal investigations were scrutinized regarding the amount of BIC and to assess implant longevity clinical data were evaluated. Results: The PubMed search yielded 349 titles and the Cochrane/MEDLINE search yielded 881 titles. Based upon abstract screening and discarding duplicates from both searches, 100 full‐text articles were obtained and subjected to additional evaluation. A further publication was included based on the manual search. The selection process resulted in the final sample of 25 studies. No (randomized) controlled clinical trials regarding the outcome of zirconia and alumina ceramic implants could be found. The systematic review identified histological animal studies showing similar BIC between alumina, zirconia and titanium. Clinical investigations using different alumina oral implants up to 10 years showed survival/success rates in the range of 23 to 98% for different indications. The included zirconia implant studies presented a survival rate from 84% after 21 months to 98% after 1 year. Conclusions: No difference was found in the rate of osseointegration between the different implant materials in animal experiments. Only cohort investigations were located with questionable scientific value. Alumina implants did not perform satisfactorily and therefore, based on this review, are not a viable alternative to titanium implants. Currently, the scientific clinical data for ceramic implants in general and for zirconia implants in particular are not sufficient to recommend ceramic implants for routine clinical use. Zirconia, however, may have the potential to be a successful implant material, although this is as yet unsupported by clinical investigations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2009.01785.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 380

Metadata

Authors
Andreiotelli, M., Wenz, H. J., & Kohal, R.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2009-07-24
Volume
20
Issue
s4
Pages
32-47
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W2130411719
Cited by
380
References
0
FWCI
2.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Are ceramic implants a viable alternative to titanium implants? A systematic literature review. https://app.cochat.ai/papers/10.1111/j.1600-0501.2009.01785.x
The paper
Andreiotelli, M., Wenz, H. J., & Kohal, R. (2009). Are ceramic implants a viable alternative to titanium implants? A systematic literature review. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2009.01785.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.