The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
PEEK Dental Implants: A Review of the Literature
Open accessAbstract
The insertion of dental implants containing titanium can be associated with various complications (eg, hypersensitivity to titanium). The aim of this article is to evaluate whether there are existing studies reporting on PEEK (polyetheretherketone) as an alternative material for dental implants. A systematic literature search of PubMed until December 2010 yielded 3 articles reporting on dental implants made from PEEK. One article analyzed stress distribution in carbon fiber-reinforced PEEK (CFR-PEEK) dental implants by the 3-dimensional finite element method, demonstrating higher stress peaks due to a reduced stiffness compared to titanium. Two articles reported on investigations in mongrel dogs. The first article compared CFR-PEEK to titanium-coated CFR-PEEK implants, which were inserted into the femurs and evaluated after 4 and 8 weeks. The titanium-coated implants showed significantly higher bone-implant contact (BIC) rates. In a second study, implants of pure PEEK were inserted into the mandibles beside implants made from titanium and zirconia and evaluated after 4 months, where PEEK presented the lowest BIC. The existing articles reporting on PEEK dental implants indicate that PEEK could represent a viable alternative material for dental implants. However, further experimental studies on the chemical modulation of PEEK seem to be necessary, mainly to increase the BIC ratio and to minimize the stress distribution to the peri-implant bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PEEK biomaterials in trauma, orthopedic, and spinal implants
Kurtz, S. M., & Devine, J. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.013 · Cited by 2,388
Intra-Osseous Anchorage of Dental Prostheses:I. Experimental Studies
Brånemark, P.-I., Breine, U., Adell, R., Hansson, B. O., Lindström, J., & Ohlsson, Å. (1969) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844316909036699 · Cited by 1,811
HUISKES, R., WEINANS, H., & RIETBERGEN, B. V. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199201000-00014 · Cited by 1,213
Intra-osseous anchorage of dental prostheses. I. Experimental studies
Brånemark, P., Breine, U., Adell, R., Hansson, B. O., Lindström, J., & Ohlsson, A. (1971) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-197107000-00067 · Cited by 508
Are ceramic implants a viable alternative to titanium implants? A systematic literature review
Andreiotelli, M., Wenz, H. J., & Kohal, R. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01785.x · Cited by 380
Zirconia Dental Implants: A Literature Review
Özkurt, Z., & Kazazoğlu, E. (2011) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-09-00079 · Cited by 347
Perspectives: bone's mechanical usage windows
Frost, H. M. (1992) · Bone and Mineral · doi:10.1016/0169-6009(92)90875-e · Cited by 292
In vivo fracture resistance of implant-supported all-ceramic restorations
Yildirim, M., Fischer, H., Marx, R., & Edelhoff, D. (2003) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(03)00514-6 · Cited by 213
Hypersensitivity to titanium: clinical and laboratory evidence.
Stankovská, M., Hrabárová, E., Valachová, K., Molnárová, M., Gemeiner, P., & Soltés, L. (2006) · PubMed · Cited by 188
Nonalloyed titanium as a bioinert metal—A review
Tschernitschek, H., Borchers, L., & Geurtsen, W. (2006) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2006.02.020 · Cited by 160
Cited by
Surface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
General review of titanium toxicity
Kim, K. T., Eo, M. Y., Nguyen, T. T. H., & Kim, S. M. (2019) · International Journal of Implant Dentistry · doi:10.1186/s40729-019-0162-x · Cited by 404
Han, X., Yang, D., Yang, C., Spintzyk, S., Scheideler, L., Li, P., Li, D., Geis-Gerstorfer, J., & Rupp, F. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020240 · Cited by 361
Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses
Alqurashi, H., Khurshid, Z., Syed, A. U. Y., Rashid Habib, S., Rokaya, D., & Zafar, M. S. (2021) · Journal of Advanced Research · doi:10.1016/j.jare.2020.09.004 · Cited by 300
Zoidis, P., Papathanasiou, I., & Polyzois, G. (2016) · Journal of Prosthodontics · doi:10.1111/jopr.12325 · Cited by 284
Metadata
- Authors
- Schwitalla, A., & Müller, W.-D.
- Venue
- Journal of Oral Implantology
- Published
- 2013-12
- Volume
- 39
- Issue
- 6
- Pages
- 743-749
- ISSN
- 0160-6972 (ISSN-L)
- 1548-1336
- OpenAlex
- W2158162507
- Cited by
- 340
- References
- 20
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PEEK Dental Implants: A Review of the Literature. https://app.cochat.ai/papers/10.1563/aaid-joi-d-11-00002
- The paper
- Schwitalla, A., & Müller, W.-D. (2013). PEEK Dental Implants: A Review of the Literature. Journal of Oral Implantology. https://doi.org/10.1563/aaid-joi-d-11-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.