Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 280

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Bone dimensional variations at implants placed in fresh extraction sockets: a multilevel multivariate analysis

Tomasi, Cristiano, Sanz, Mariano, Cecchinato, Denis, Pjetursson, Bjarni, Ferrus, Jorge, Lang, Niklaus P., Lindhe, Jan·2010·Clinical Oral Implants Research

Abstract

Aim: To use multilevel, multivariate models to analyze factors that may affect bone alterations during healing after an implant immediately placed into an extraction socket. Material and methods: Data included in the current analysis were obtained from a clinical trial in which a series of measurements were performed to characterize the extraction site immediately after implant installation and at re‐entry 4 months later. A regression multilevel, multivariate model was built to analyze factors affecting the following variables: (i) the distance between the implant surface and the outer bony crest (S‐OC), (ii) the horizontal residual gap (S‐IC), (iii) the vertical residual gap (R‐D) and (iv) the vertical position of the bone crest opposite the implant (R‐C). Results: It was demonstrated that (i) the S‐OC change was significantly affected by the thickness of the bone crest; (ii) the size of the residual gap was dependent of the size of the initial gap and the thickness of the bone crest; and (iii) the reduction of the buccal vertical gap was dependent on the age of the subject. Moreover, the position of the implant opposite the alveolar crest of the buccal ridge and its bucco‐lingual implant position influenced the amount of buccal crest resorption. Conclusions: Clinicians must consider the thickness of the buccal bony wall in the extraction site and the vertical as well as the horizontal positioning of the implant in the socket, because these factors will influence hard tissue changes during healing. To cite this article: Tomasi C, Sanz M, Cecchinato D, Pjetursson B, Ferrus J, Lang NP, Lindhe J. Bone dimensional variations at implants placed in fresh extraction sockets: a multilevel multivariate analysis. Clin. Oral Impl. Res. 21, 2010; 30–36.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0501.2009.01848.x

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 280

Metadata

Authors
Tomasi, C., Sanz, M., Cecchinato, D., Pjetursson, B., Ferrus, J., Lang, N. P., & Lindhe, J.
Venue
Clinical Oral Implants Research
Publisher
Wiley
Published
2009-12-15
Volume
21
Issue
1
Pages
30-36
ISSN
  • 0905-7161 (ISSN-L)
  • 1600-0501
OpenAlex
W1586439798
Cited by
280
References
16
FWCI
12.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bone dimensional variations at implants placed in fresh extraction sockets: a multilevel multivariate analysis. https://app.cochat.ai/papers/10.1111/j.1600-0501.2009.01848.x
The paper
Tomasi, C., Sanz, M., Cecchinato, D., Pjetursson, B., Ferrus, J., Lang, N. P., & Lindhe, J. (2010). Bone dimensional variations at implants placed in fresh extraction sockets: a multilevel multivariate analysis. Clinical Oral Implants Research. https://doi.org/10.1111/j.1600-0501.2009.01848.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.