The DOI matches its Crossref record.
Description and clinical evaluation of a new computerized periodontal probe‐the Florida Probe
Abstract
A new periodontal probing system has been developed which incorporates the advantages of constant probing force, precise electronic measurement to 0.1 mm and computer storage of the data. The system includes a probe handpiece, displacement transducer with digital readout, foot switch, computer interface and personal computer. A unique movable arm design enables the probe handpiece to maintain smooth operation and makes it easy to clean and sterilize. Electronic recording of the data (actuated by pressing a foot switch) eliminates errors which occur when probe tip markings are read visually and the data are called to an assistant. Computer storage and analysis of the data facilitates detecting changes in pocket depth and attachment level by rapidly comparing data recorded at different visits. The system was evaluated in 3 experiments using a 0.4 mm diameter tip and a 25 g probing force. The standard deviation of repeated pocket depth measurement was less (0,58 mm versus 0.82 mm) than that of a common probe. With paired readings referenced to an occlusal stent, the standard deviation of repeated attachment level measurements was 0.28 mm. A loss of attachment level was detected to a certainty of 99% with less than a I mm change. This is a significant improvement over common probes, which require a 2–3 mm change for equivalent positive identification of change in attachment level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non‐Surgical Pocket Therapy: Mechanical
Cobb, C. M. (1996) · Annals of Periodontology · doi:10.1902/annals.1996.1.1.443 · Cited by 593
Savage, A., Eaton, K. A., Moles, D. R., & Needleman, I. (2009) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2009.01408.x · Cited by 493
Plaque‐induced gingivitis: Case definition and diagnostic considerations
Trombelli, L., Farina, R., Silva, C. O., & Tatakis, D. N. (2018) · Journal of Clinical Periodontology · doi:10.1111/jcpe.12939 · Cited by 447
Plaque‐induced gingivitis: Case definition and diagnostic considerations
Trombelli, L., Farina, R., Silva, C. O., & Tatakis, D. N. (2018) · Journal of Periodontology · doi:10.1002/jper.17-0576 · Cited by 421
Van Strydonck, D. A. C., Slot, D. E., Van der Velden, U., & Van der Weijden, F. (2012) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2012.01883.x · Cited by 353
Metadata
- Authors
- Gibbs, C. H., Hirschfeld, J. W., Lee, J. G., Low, S. B., Magnusson, I., Thousand, R. R., Yemeni, P., & Clark, W. B.
- Venue
- Journal of Clinical Periodontology
- Publisher
- Wiley
- Published
- 1988-02
- Volume
- 15
- Issue
- 2
- Pages
- 137-144
- ISSN
- 0303-6979 (ISSN-L)
- 1600-051X
- OpenAlex
- W2141541055
- Cited by
- 238
- References
- 0
- FWCI
- 11.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Description and clinical evaluation of a new computerized periodontal probe‐the Florida Probe. https://app.cochat.ai/papers/10.1111/j.1600-051x.1988.tb01008.x
- The paper
- Gibbs, C. H., Hirschfeld, J. W., Lee, J. G., Low, S. B., Magnusson, I., Thousand, R. R., Yemeni, P., & Clark, W. B. (1988). Description and clinical evaluation of a new computerized periodontal probe‐the Florida Probe. Journal of Clinical Periodontology. https://doi.org/10.1111/j.1600-051x.1988.tb01008.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.