The DOI matches its Crossref record.
Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis?
Abstract
In spite of the improved awareness of the potential for nickel, cobalt and chromium to en use skin allergy, the incidence of serialization to them is generally on the increase, especially for nickel. We review data from the literature and industry on transition metal contamination of consumer products and assess the hazard to man. Consumer products are defined as personal care items and detergent/cleaning products used regularly in domestic York. The analytical data demonstrate that consumer products are a relatively minor source of contact with nickel, cobalt or chromium. The traces found in consumer products will not be the primary cause of sensitization to these metals: levels will be too low and exposure too brief. A person sensitized to these metals has many other more significant sources of daily contact such as earrings, jewellery and metal objects. It is therefore necessary to focus on decreasing the high exposure to these transition metals from other sources rather than on possible trace amounts found in consumer products. Current good manufacturing practice ensures that trace nickel, cobalt and chromium concentrations in consumer products are less than 5 ppm of each metal, it is recommended that this be accepted as a standard for maximum concentrations and that the target should be to achieve concentrations as low as 1 ppm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cobalt toxicity in humans—A review of the potential sources and systemic health effects
Leyssens, L., Vinck, B., Van Der Straeten, C., Wuyts, F., & Maes, L. (2017) · Toxicology · doi:10.1016/j.tox.2017.05.015 · Cited by 1,045
Metal Sensitivity in Patients with Orthopaedic Implants
Hallab, N., Merritt, K., & Jacobs, J. J. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200103000-00017 · Cited by 935
Metal Allergy—A Review on Exposures, Penetration, Genetics, Prevalence, and Clinical Implications
Thyssen, J. P., & Menné, T. (2010) · Chemical Research in Toxicology · doi:10.1021/tx9002726 · Cited by 398
Investigation of the threshold for allergic reactivity to chromium
Basketter, D., Horev, L., Slodovnik, D., Merimes, S., Trattner, A., & Ingber, A. (2001) · Contact Dermatitis · doi:10.1034/j.1600-0536.2001.440202.x · Cited by 102
Self-citation
Metadata
- Authors
- Basketter, D. A., Briatico‐Vangosa, G., Kaestner, W., Lally, C., & Bontinck, W. J.
- Venue
- Contact Dermatitis
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 28
- Issue
- 1
- Pages
- 15-25
- ISSN
- 0105-1873 (ISSN-L)
- 1600-0536
- OpenAlex
- W2085181717
- Cited by
- 257
- References
- 0
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis? https://app.cochat.ai/papers/10.1111/j.1600-0536.1993.tb03318.x
- The paper
- Basketter, D. A., Briatico‐Vangosa, G., Kaestner, W., Lally, C., & Bontinck, W. J. (1993). Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis? Contact Dermatitis. https://doi.org/10.1111/j.1600-0536.1993.tb03318.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.