CoChat

Mechanical Ventilation in Office Buildings and the Sick Building Syndrome. An Experimental and Epidemiological Study

Jaakkola, Jouni J.K., Heinoneon, Olli P., Seppanen, Olli · 1991 · Indoor Air
Cited by 130

The DOI matches its Crossref record.

Abstract

The effects of mechanical ventilation on the sick building syndrome (SBS) were studied in an office building with 2150 employees, where the mechanical ventilation and indoor air quality were commonly blamed for causing symptoms typical of the SBS (nasal, eye, and mucous membrane symptoms, lethargy, skin symptoms and headache). The mechanical ventilation rates in the building were high (mean 26 l/s/person). To test the hypothesis that mechanical ventilation causes the SBS, a controlled experimental study was carried out by shutting off the ventilation in one part of the building and reducing the ventilation rate by 75% and 60% in two areas while leaving one part unaltered as a control. The experimental reduction of the ventilation rate did not alleviate the symptoms. On the contrary, the reduction of the ventilation rate caused a slight but statistically significant relative increase in symptoms (p < 0.05). In the cross-sectional analysis of the baseline data the SBS symptoms did not associate significantly with the ventilation rate (range 7–70 l/s/person). In the linear regression model, a positive correlation was found between temperatures above 22°C and the occurrence of symptoms (p < 0.05). Subjects exposed to environmental tobacco smoke had more symptoms than those not exposed (p < 0.01). Women reported more symptoms than men (p < 0.001). In addition, any prior history of allergic diseases (p < 0.001) and a negative attitude towards the social atmosphere at work (p < 0.001) were significant determinants of the SBS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.1991.02-12.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 130

Metadata

Authors
Jaakkola, J. J. K., Heinoneon, O. P., & Seppanen, O.
Venue
Indoor Air
Published
1991-07
Volume
1
Issue
2
Pages
111-121
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2008126816
Cited by
130
References
0
FWCI
12.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical Ventilation in Office Buildings and the Sick Building Syndrome. An Experimental and Epidemiological Study. https://app.cochat.ai/papers/10.1111/j.1600-0668.1991.02-12.x
The paper
Jaakkola, J. J. K., Heinoneon, O. P., & Seppanen, O. (1991). Mechanical Ventilation in Office Buildings and the Sick Building Syndrome. An Experimental and Epidemiological Study. Indoor Air. https://doi.org/10.1111/j.1600-0668.1991.02-12.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.