Subjective Indoor Air Quality in Schools in Relation to Exposure
Open accessThe DOI matches its Crossref record.
Abstract
This paper presents data on indoor air quality in schools as perceived by those working in them and relates these data to exposure measurements. Data on subjective air quality, domestic exposures and health aspects were gathered by means of a questionnaire which was sent to all personnel in 38 schools; it was completed by 1410 persons (85’4 of the total). Data on exposure were gathered by exposure measurements in classrooms. The results indicate that 53% of the personnel perceived the indoor air quality as bad or very bad. It was perceived as worse by those who were younger, those who were dissatisfied with their psychosocial work climate and those who were not exposed to tobacco smoke at home. In older school buildings and buildings with displacement ventilation there was less dissatisfaction with the air quality. There were no significant relations between complaints and air exchange rate or concentration of carbon dioxide. The air quality was perceived as worse at higher levels of exposure to a number of airborne compounds including volatile organic compounds, moulds, bacteria and respirable dust. It was concluded that exposure to indoor pollutants affects perception even at the low concentrations normally found indoors in nonindustrial buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Literature survey on how different factors influence human comfort in indoor environments
Frontczak, M., & Wargocki, P. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.10.021 · Cited by 1,248
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Child development and the physical environment.
Evans, G. W. (2006) · Annual Review of Psychology · doi:10.1146/annurev.psych.57.102904.190057 · Cited by 814
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
“…of daylight (Pepler, 1968; Green, 1974, 1985; Norback et al., 1990; Ruotsalainen et al., 1995; Myhrvold et al., 1996; Myhrvold and Olsen, 1997; Smedje et al., 1997; Walinder et al., 1997a, 1997b, 1998; Meyer et al., 1999; Ahman et al., 2000; Smedje and Norback, 2000, Kim et al., 2002;…”
Metadata
- Authors
- Smedje, G., Norback, D., & Edling, C.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1997-06
- Volume
- 7
- Issue
- 2
- Pages
- 143-150
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2081256923
- Cited by
- 119
- References
- 0
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subjective Indoor Air Quality in Schools in Relation to Exposure. https://app.cochat.ai/papers/10.1111/j.1600-0668.1997.00009.x
- The paper
- Smedje, G., Norback, D., & Edling, C. (1997). Subjective Indoor Air Quality in Schools in Relation to Exposure. Indoor Air. https://doi.org/10.1111/j.1600-0668.1997.00009.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.