Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Abstract
Unlabelled Student attendance in American public schools is a critical factor in securing limited operational funding. Student and teacher attendance influence academic performance. Limited data exist on indoor air and environmental quality (IEQ) in schools, and how IEQ affects attendance, health, or performance. This study explored the association of student absence with measures of indoor minus outdoor carbon dioxide concentration (dCO(2)). Absence and dCO(2) data were collected from 409 traditional and 25 portable classrooms from 22 schools located in six school districts in the states of Washington and Idaho. Study classrooms had individual heating, ventilation, and air conditioning (HVAC) systems, except two classrooms without mechanical ventilation. Classroom attributes, student attendance and school-level ethnicity, gender, and socioeconomic status (SES) were included in multivariate modeling. Forty-five percent of classrooms studied had short-term indoor CO(2) concentrations above 1000 p.p.m. A 1000 p.p.m. increase in dCO(2) was associated (P Practical implications This study provides motivation for larger school studies to investigate associations of student attendance, and occupant health and student performance, with longer term indoor minus outdoor CO(2) concentrations and more accurately measured ventilation rates. If our findings are confirmed, improving classroom ventilation should be considered a practical means of reducing student absence. Adequate or enhance…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cited by
Sorted by citations
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064 · see citing works
Self-citationAllen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977 · see citing works
“Corsi et al. (2002) reported CO 2 concentrations > 1,000 ppm in 66% of 120 classrooms in Texas, and Shendell et al. (2004) measured CO 2 concentrations > 1,000 ppm in 45% of 435 classrooms in Washington and Idaho and reported that elevated CO 2 concentrations were associated with increases in…”
BackgroundVentilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740 · see citing works
Self-citationAssociation between substandard classroom ventilation rates and students’ academic achievement
Haverinen-Shaughnessy, U., Moschandreas, D. J., & Shaughnessy, R. J. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00686.x · Cited by 311 · see citing works
Wargocki, P., & Wyon, D. P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.020 · Cited by 290 · see citing works
Batterman, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14020145 · Cited by 271 · see citing works
Persily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249 · see citing works
Indoor air quality investigation according to age of the school buildings in Korea
Yang, W., Sohn, J., Kim, J., Son, B., & Park, J. (2009) · Journal of Environmental Management · doi:10.1016/j.jenvman.2007.10.003 · Cited by 235 · see citing works
Shaughnessy, R. J., Haverinen-Shaughnessy, U., Nevalainen, A., & Moschandreas, D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00440.x · Cited by 230 · see citing works
Law, J., Van Baalen, M., Foy, M., Mason, S. S., Mendez, C., Wear, M. L., Meyers, V. E., & Alexander, D. (2014) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000000158 · Cited by 168 · see citing works
Control of CO2 in a naturally ventilated classroom
Griffiths, M., & Eftekhari, M. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.04.013 · Cited by 159 · see citing works
Mejía, J. F., Choy, S. L., Mengersen, K., & Morawska, L. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.11.009 · Cited by 131 · see citing works
Ozone, heat and mortality: acute effects in 15 British conurbations
Pattenden, S., Armstrong, B., Milojevic, A., Heal, M. R., Chalabi, Z., Doherty, R., Barratt, B., Kovats, R. S., & Wilkinson, P. (2010) · Occupational and Environmental Medicine · doi:10.1136/oem.2009.051714 · Cited by 108 · see citing works
Development and application of an indoor carbon dioxide metric
Persily, A. (2022) · Indoor Air · doi:10.1111/ina.13059 · Cited by 104 · see citing works
Comfort Parameters and Particulate Matter (PM10 and PM2.5) in School Classrooms and Outdoor Air
Alves, C., Nunes, T., Silva, J., & Duarte, M. (2013) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.11.0321 · Cited by 88 · see citing works
“Researchers have been looking for links between elevated CO 2 concentrations and reduced attendance, productivity or achievement (Shendell et al. , 2004; Wargocki and Wyon, 2006).”
- Authors
- Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- Washington State University Spokane (US)
- Corresponding author
- Fisk, W. J.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2004-10
- Volume
- 14
- Issue
- 5
- Pages
- 333-341
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2094324783
- Cited by
- 462
- References
- 0
- Citations by year
- 2026: 19 · 2025: 26 · 2024: 25 · 2023: 26 · 2022: 31 · 2021: 33 · 2020: 38 · 2019: 26 · 2018: 25 · 2017: 24 · 2016: 20 · 2015: 36 · 2014: 23 · 2013: 17 · 2012: 21
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Indoor Air (publishedVersion)
- PubMed (publishedVersion)
- University of North Texas Digital Library (University of North Texas) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Lawrence Berkeley National Laboratory
- Funders
- U.S. Environmental Protection Agency
- National Institute of Standards and Technology
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- student attendance, school absenteeism, indoor air quality, school ventilation, portable classrooms, traditional classroom, HVAC systems, ventilation rate, school health, Washington, Idaho
- MeSH terms
- Absenteeism, Air Pollutants, Analysis of Variance, Carbon Dioxide, Child, Child, Preschool, Female, Humans, Idaho, Male, Schools, Students, Ventilation, Washington, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review