Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices
Open accessAbstract
UNLABELLED: In groups of six, 30 female subjects were exposed for 4.8 h in a low-polluting office to each of two conditions--the presence or absence of 3-month-old personal computers (PCs). These PCs were placed behind a screen so that they were not visible to the subjects. Throughout the exposure the outdoor air supply was maintained at 10 l/s per person. Under each of the two conditions the subjects performed simulated office work using old low-polluting PCs. They also evaluated the air quality and reported Sick Building Syndrome (SBS) symptoms. The PCs were found to be strong indoor pollution sources, even after they had been in service for 3 months. The sensory pollution load of each PC was 3.4 olf, more than three times the pollution of a standard person. The presence of PCs increased the percentage of people dissatisfied with the perceived air quality from 13 to 41% and increased by 9% the time required for text processing. Chemical analyses were performed to determine the pollutants emitted by the PCs. The most significant chemicals detected included phenol, toluene, 2-ethylhexanol, formaldehyde, and styrene. The identified compounds were, however, insufficient in concentration and kind to explain the observed adverse effects. This suggests that chemicals other than those detected, so-called 'stealth chemicals', may contribute to the negative effects. PRACTICAL IMPLICATIONS: PCs are an important, but hitherto overlooked, source of pollution indoors. They can decrease the perceived air quality, increase SBS symptoms and decrease office productivity. The ventilation rate in an office with a 3-month-old PC would need to be increased several times to achieve the same perceived air quality as in a low-polluting office with the PC absent. Pollution from PCs has an important negative impact on the air quality, not only in offices but also in many other spaces, including homes. PCs may have played a role in previously published studies on SBS and perceived air quality, where PCs were overlooked as a possible pollution source in the indoor environment. The fact that the chemicals identified in the office air and in the chamber experiments were insufficient to explain the adverse effects observed during human exposures illustrates the inadequacy of the analytical chemical methods commonly used in indoor air quality investigations. For certain chemicals the human senses are much more sensitive than the chemical methods routinely used in indoor air quality investigations. The adverse effects of PC-generated air pollutants could be reduced by modifications in the manufacturing process, increased ventilation, localized PC exhaust, or personalized ventilation systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Over 70% of a pupil's school life is spent inside a classroom”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [18]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ozone in Indoor Environments: Concentration and Chemistry
Weschler, C. J. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004269.x · Cited by 762
Self-citationWargocki, P. L., Wyon, D. P., Sundell, J., Clausen, G., & Fanger, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 693
Self-citationWargocki, P. L., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 509
Self-citationStandardized Human Olfactory Thresholds
(1990) · doi:10.1093/oso/9780199631469.001.0001 · Cited by 506
Flame Retardants in Indoor Air at an Electronics Recycling Plant and at Other Work Environments
Sjödin, A., Carlsson, H., Thuresson, K., Sjölin, S., Bergman, Å., & Östman, C. E. (2000) · Environmental Science & Technology · doi:10.1021/es000077n · Cited by 501
Fanger, P. O. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90051-5 · Cited by 372
Self-citationOrganic compounds in indoor air—their relevance for perceived indoor air quality?
Wolkoff, P., & Nielsen, G. D. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00244-8 · Cited by 371
Potential reactions among indoor pollutants
Weschler, C. J., & Shields, H. C. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(97)00219-7 · Cited by 263
Self-citationProceedings of Healthy Buildings
Brohus, H. (2006) · Cited by 247
Work with video display terminals among office employees. I. Subjective symptoms and discomfort.
KNAVE, B. G., Wibom, R., Voss, M., Hedstrom, L. D., & Bergqvist, U. (1985) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.2200 · Cited by 199
Research works printed but not linked: 16
- Black M.S., 1999, Proceedings of Indoor Air '99, 8th International Conference on Indoor Air Quality and Climate, 454
- Burr H., 2000, Danskernes anvendelse af computere pa arbejdet 1999
- Clements-Croome D., 2001, Proceedings of Clima 2000, 7th REHVA World Congress
- Committee on Man and Radiation (COMAR), 1997, IEEE Eng. Med. Biol., 16, 87
- Corsi R.L., 2000, Presented Poster: Annual Meeting of the International Society for Exposure Analysis 2000
- Funaki R., 2002, Summaries of Technical Papers of Annual Meeting of Architectural Institute of Japan, 863
- ISO, 1988, Sensory analysis - Methodology - Ranking Test
- ISO, 1993, Sensory Analysis - General Guidance for the Selection, Training and Monitoring of Assessors - Part 1: Selected Assessors
- Pejtersen J., 1999, Proceedings of Indoor Air 1999, 160
- Salthammer T., 2002, Proceedings of Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate, 213
- Skyberg K., 1997, Proceedings of HCI International '97, 7th International Conference on Human-Computer Interaction, 655
- TCO '99, 1998, Requirements and Test Methods for Environmental Labelling of Displays (CRT)
- Wensing M., 1999, Proceedings of Indoor Air '99, 8th International Conference on Indoor Air Quality and Climate, 87
- Wensing M., 2002, Proceedings of Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate, 554
- WHO Fact Sheets, 1998, Video Display Units (VDUs) and Human Health
- WHO Fact Sheets, 1998, Electromagnetic Fields and Public Health: Extremely low frequency (ELF)
Cited by
Sorted by citations
Items 101–183 of 183
Torriani, G., Torresin, S., Albatici, R., & Babich, F. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.111758 · Cited by 14
ESTIMATION OF THE EFFECTIVENESS OF RENOVATION WORK IN LITHUANIAN SCHOOLS
Pikutis, R., & Šeduikytė, L. (2006) · Journal of Civil Engineering and Management · doi:10.3846/13923730.2006.9636388 · Cited by 14
Jo, W., & Kim, J.-D. (2010) · Chemosphere · doi:10.1016/j.chemosphere.2010.09.020 · Cited by 13
Improving indoor air quality improves the performance of office work and schoolwork
Wargocki, P. L. (2007) · Cited by 13
Self-citationModeling of Subjective Responses to Indoor Air Quality and Thermal Conditions in Office Buildings
Kostiainen, T., Welling, I., Lahtinen, M., Salmi, K., Kähkönen, E., & Lampinen, J. (2008) · Science and Technology for the Built Environment · doi:10.1080/10789669.2008.10391046 · Cited by 12
Kamijima, M., Shibata, E., Sakai, K., Ohno, H., Ishihara, S., Yamada, T., Takeuchi, Y., & Nakajima, T. (2005) · PubMed · doi:10.11236/jph.52.12_1021 · Cited by 12
Biosensors: A Biotechnological Tool for Monitoring Environmental Pollution
Ali, R., & Singh, D. V. (2020) · Springer eBooks · doi:10.1007/978-3-030-46075-4_15 · Cited by 11
Characterization of chemical transport in human skin and building material
Wang, H., Wang, H., Wang, K., Xiong, J., Huang, S., Wolfson, J. M., & Koutrakis, P. (2023) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2023.131917 · Cited by 11
Glas, B., Stenberg, B., Stenlund, H. C., & Sunesson, A.-L. (2008) · Journal of Environmental Monitoring · doi:10.1039/b808654k · Cited by 11
Barkhordari, A., Kheirmand, M., Mosaddegh, M. H., & Farajzadegan, Z. (2014) · International Journal of Environmental Health Engineering · doi:10.4103/2277-9183.139745 · Cited by 11
Indoor Air Quality in Nonindustrial Occupational Environments
Morey, P. R., Crawford, G. N., & Rottersman, R. (2011) · Patty's Industrial Hygiene · doi:10.1002/0471435139.hyg065.pub2 · Cited by 11
Peng, Z., Cheng, Y., Jiang, M., Shu, S., & Geng, X. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107065 · Cited by 10
Ivanov, M. (2016) · Energy Procedia · doi:10.1016/j.egypro.2015.12.255 · Cited by 10
The Effect of Personalized Ventilation on Work Productivity
Bogdan, M., Łuczak, A., Chludzińska, M., & Zwolińska, M. (2012) · International Journal of Ventilation · doi:10.1080/14733315.2012.11683973 · Cited by 10
Matić, B., Rakić, U., Jovanović, V., Dejanović, S., & Djonović, N. (2017) · Slovenian Journal of Public Health · doi:10.1515/sjph-2017-0031 · Cited by 10
Wu, S. R., & Apul, D. S. (2015) · Journal of Green Building · doi:10.3992/jgb.10.1.127 · Cited by 12
Provision of Environmentally Responsible Interior Design Solutions: Case Study of an Office Building
Fadeyi, M. O., & Taha, R. G. A. (2012) · Journal of Architectural Engineering · doi:10.1061/(asce)ae.1943-5568.0000098 · Cited by 10
FIELD MEASURMENT OF SVOC IN INDOOR AIR AND HOUSE DUST IN RESIDENTIAL BUILDINGS
Kim, H., & Tanabe, S. (2016) · Journal of Environmental Engineering (Transactions of AIJ) · doi:10.3130/aije.81.199 · Cited by 10
Measurements of Chemical Emission Rates from Portable PC and Electronic Appliances
Funaki, R., Tanabe, S., Tanaka, H., & Nakagawa, T. (2003) · Journal of Asian Architecture and Building Engineering · doi:10.3130/jaabe.2.b55 · Cited by 9
Applied Horticultural Biotechnology for the Mitigation of Indoor Air Pollution
Torpy, F. R., Pettit, T. J., & Irga, P. J. (2018) · Journal of people, plants, and environment · doi:10.11628/ksppe.2018.21.6.445 · Cited by 9
An efficient lattice Boltzmann model for indoor airflow and particle transport
Ding, L., & Lai, A. C. K. (2013) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2013.04.004 · Cited by 9
Indoor Air Quality and Office Property Value
Addae‐Dapaah, K., Tham, K. W., Dollah, M. J. B., & Foo, Y. (2010) · Journal of Sustainable Real Estate · doi:10.1080/10835547.2010.12091799 · Cited by 9
Secondary Criteria Air Pollutants: Environmental Health Effects
Saxena, P., & Sonwani, S. (2019) · Springer eBooks · doi:10.1007/978-981-13-9992-3_4 · Cited by 9
Emission of VOCs and SVOCs from Electronic Devices and Office Equipment
Schripp, T., & Wensing, M. (2009) · Wiley eBooks · doi:10.1002/9783527628889.ch17 · Cited by 9
Orru, H., Olstrup, H., Hagenbjörk, A., Nordin, S., & Orru, K. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19105789 · Cited by 8
Potted plants and ventilation effectively remove pollutants from tobacco smoke
Liu, C., Zhang, N., Sun, L., Gao, W., Zang, Q., & Wang, X. (2022) · International Journal of Low-Carbon Technologies · doi:10.1093/ijlct/ctac081 · Cited by 8
Choi, S. (2011) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 8
Causes and prevention of symptom complaints in office buildings
Mendell, M. J., Brennan, T., Hathon, L., Odom, J. D., Offermann, F. J., Turk, B. H., Wallingford, K. M., Diamond, R. C., & Fisk, W. J. (2006) · Facilities · doi:10.1108/02632770610701549 · Cited by 7
Ding, L., Fung, J. L. S., Seepana, S., & Lai, A. C. K. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.12.006 · Cited by 7
The Impact of Sick Building Syndrome on Call Centre Agents’ Effectiveness
Oodith, D. (2012) · Journal of Economics and Behavioral Studies · doi:10.22610/jebs.v4i9.355 · Cited by 7
Kim, T.-H., Lee, H., Choi, B.-H., & Hyun, H. S. (2021) · Journal of people, plants, and environment · doi:10.11628/ksppe.2021.24.2.179 · Cited by 7
Artificial neural network analysis of teachers’ performance against thermal comfort
Alzahrani, H., Arif, M., Kaushik, A. K., Goulding, J. S., & Heesom, D. (2018) · International Journal of Building Pathology and Adaptation · doi:10.1108/ijbpa-11-2019-0098 · Cited by 6
Environmental experience design research spectrum for energy and human well-being
Noguchi, M., Lan, L., Chowdhury, S., & Yang, W. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824084-7.00002-3 · Cited by 6
Gupta, P. K. (2011) · Journal of Green Engineering · Cited by 6
The effects of indoor and outdoor air pollutants on workers’ productivity in office building
Becchio, C., Bottero, M., Corgnati, S. P., Dell’Anna, F., Fabi, V., Lingua, C., Prendin, L., & Ranieri, M. (2019) · E3S Web of Conferences · doi:10.1051/e3sconf/201911102057 · Cited by 6
Material Odor Emissions and Indoor Air Quality
Burdack‐Freitag, A., Heinlein, A., & Mayer, F. (2017) · Springer eBooks · doi:10.1007/978-3-319-26932-0_26 · Cited by 6
Quantifying Pollutant Emissions from Office Equipment Phase IReport
Maddalena, R. L., USDOE, Destaillats, H., Hodgson, A., McKone, T. E., & Perino, C. (2006) · doi:10.2172/918677 · Cited by 6
Jensen, K. L., Spiild, H., & Toftum, J. (2011) · International Journal of Biometeorology · doi:10.1007/s00484-011-0404-y · Cited by 5
Xiang, Y., Amada, K., Mishra, A. K., Tanabe, S.-I., Fang, L., & Wargocki, P. L. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116152 · Cited by 4
Self-citationGuan, H., Jia, Q., Guo, Z., Han, X., Zhang, H., Hao, L., Wu, C., & Liu, J. (2024) · Molecules · doi:10.3390/molecules29184445 · Cited by 4
The Effect of Students, Computers, and Air Purifiers on Classroom Air Quality
Dabanlis, G., Loupa, G., Liakos, D., & Rapsomanikis, S. (2022) · Applied Sciences · doi:10.3390/app122311911 · Cited by 4
Investigation of Air Pollution in a Shopping Center and Employees' Personal Exposure Level
Manabe, R., Kunugita, N., Katoh, T., Kuroda, Y., Akiyama, Y., Yamano, Y., Uchiyama, I., & Arashidani, K. (2008) · Nippon Eiseigaku Zasshi (Japanese Journal of Hygiene) · doi:10.1265/jjh.63.20 · Cited by 4
Aduda, K. K., Mocanu, E., Boxem, G., Nguyen, P. H., Kling, W. L., & Zeiler, W. (2014) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec.2014.6934623 · Cited by 4
Procopiou, A., & Stavrou, E. (2024) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-031-51572-9_8 · Cited by 3
Sofuoǧlu, S. C., Arı, A., Civan, M., Dumanoğlu, Y., Güllü, G., Menteşe, S., Onat, B., Şahin, Ü. A., & Toksoy, M. (2025) · Atmospheric Pollution Research · doi:10.1016/j.apr.2025.102743 · Cited by 3
Effects of IAQ on Office Work Performance
Porras-Salazar, J. A., Schiavon, S., & Tham, K. W. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_64-1 · Cited by 3
Source/Sink Characteristics of SVOCs
Wu, Y., Cao, J., Little, J. C., & Xu, Y. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_24 · Cited by 3
Material and Indoor Odors and Odorants
Mayer, F., Breuer, K., & Sedlbauer, K. P. (2009) · Wiley eBooks · doi:10.1002/9783527628889.ch8 · Cited by 3
Avaliação da qualidade do ar em ambientes internos: biblioteca pública
do Nascimento, G. C. (2011) · doi:10.11606/d.18.2011.tde-11052011-135603 · Cited by 3
Methodological aspects of unspecific building related symptoms research
Glas, B. (2010) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 3
Volatile Organic Ingredients in Household and Consumer Products
Ayoko, G. A. (2009) · Wiley eBooks · doi:10.1002/9783527628889.ch15 · Cited by 3
Zang, T., Awada, M., Becerik-Gerber, B., Roll, S. C., Lucas, G., & Narayanan, S. (2026) · Indoor Environments · doi:10.1016/j.indenv.2026.100171 · Cited by 2
Field study on economic impact of the working environments in non-temperate climates
Ahmed, R. (2014) · WIT transactions on ecology and the environment · doi:10.2495/eid140141 · Cited by 2
The Role of Demographic and Psychosocial Factors in Predicting SBS Symptoms in Workplaces
Kinman, G., & Clements, A. J. (2011) · Springer eBooks · doi:10.1007/978-3-642-17919-8_21 · Cited by 2
(2014) · Journal of Environmental Analytical Chemistry · doi:10.4172/2380-2391.1000116 · Cited by 2
The Effect of Sick Building Syndrome (SBS) on the Productivity of Administrative Staff
AHMADI, M., GOLBABAEI, F., & Behzadi, M. H. (2014) · Cited by 2
Cattaneo, A., Spinazzè, A., & Cavallo, D. M. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_77 · Cited by 2
Indoor air quality: an enviro-cultural perspective
Mansour, O. E. (2014) · WIT transactions on the built environment · doi:10.2495/arc140171 · Cited by 2
(2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00308.x · Cited by 2
Ferdyn-Grygierek, J., BARANOWSKI, A., & Kaczmarczyk, J. (2009) · Ciepłownictwo, Ogrzewnictwo, Wentylacja · Cited by 1
Paz, N., Rodriguez, J. E., & Eiceman, G. A. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.640545 · Cited by 1
2-Etyloheksan-1-ol. Dokumentacja proponowanych dopuszczalnych wielkości narażenia zawodowego
Konieczko, K., & Czerczak, S. (2015) · Podstawy i Metody Oceny Środowiska Pracy · doi:10.5604/1231868x.1192032 · Cited by 1
Mishra, A. K., Kokate, P., Lokhande, S. K., Middey, A., & Bodhe, G. L. (2017) · Water science and technology library · doi:10.1007/978-981-10-5792-2_15 · Cited by 1
CFD Investigation of Toluene Emission In a Printing Room
Khalid, A. A. A. M., Jerai, F., Zainuddin, N. A. M., Abbas, N. M., & Razak, A. A. (2024) · CFD letters · doi:10.37934/cfdl.17.5.90102 · Cited by 1
Spatial distribution of thermal comfort and work performance in a naturally ventilated auditorium
Burek, R., Połednik, B., Guz, Ł., & Badora, A. (2025) · Journal of Ecological Engineering · doi:10.12911/22998993/203124 · Cited by 1
Levels and Possible Sources of Formaldehyde in Campus
Weng, M. L. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.479-481.546 · Cited by 1
Cattaneo, A., Spinazzè, A., & Cavallo, D. M. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_77-1 · Cited by 1
Source/Sink Characteristics of SVOCs
Wu, Y., Cao, J., Little, J. C., & Xu, Y. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_24-2 · Cited by 1
Biosensors: Remediation Tool for Indoor Air Pollution
Tyagi, R., & Chaudhary, A. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-2468-2_31 · Cited by 1
Effects of IAQ on Office Work Performance
Porras-Salazar, J. A., Schiavon, S., & Tham, K. W. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_64 · Cited by 1
Negri, S., Ferrari, M., Maestri, L., GHITTORI, S., & Imbriani, M. (2004) · PubMed · Cited by 1
Notice of Retraction: Analysis the Source of Volatile Organic Compounds Emission from Particleboards
Shen, J. M., & Sun, S. (2011) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2011.5781304
RetractedKomfort cieplny użytkowników przy zastosowaniu wentylacji indywidualnej
Bogdan, M., & Chludzińska, M. (2010) · Chłodnictwo i Klimatyzacja
The Work Ability and Social Inclusion (WASI) Project
Surakka, J. (2014) · Theseus (Ammattikorkeakoulujen)
Rymarov, A. G., & Игоревич, Б. М. (2014) · Stroitel stvo nauka i obrazovanie [Construction Science and Education] · doi:10.22227/2305-5502.2014.3.4
Improvement of Workplace Ergonomics in Atrium-Type Buildings
Tint, P., Hrenov, G., Siirak, V., Traumann, A., Krichevskaya, M., & Klauson, D. (2016) · Proceedings of the Latvian Academy of Sciences Section B Natural Exact and Applied Sciences · doi:10.1515/prolas-2016-0051
Gopalakrishnan, P., Vignesh, M., Kumar, R. S. M., & Oviyaa, M. (2021) · AIP conference proceedings · doi:10.1063/5.0072655
Indoor Air Quality in Nonindustrial Occupational Environments
Springston, J. P., Horner, E., & Lstiburek, J. W. (2021) · Patty's Industrial Hygiene · doi:10.1002/0471435139.hyg065.pub3
Source and Sink Characteristics of SVOCs
Wu, Y., Cao, J., Little, J. C., & Xu, Y. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_24-1
Kumavat, U. C., Ansari, A. A., & Vichare, V. S. (2026) · Ecology Environment and Conservation · doi:10.53550/eec.2026.v32i01.020
Metadata
- Authors
- Bako-Biro, Z., Wargocki, P., Weschler, C. J., & Fanger, P. O.
- Affiliations
- Technical University of Denmark (DK)
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2004-06
- Volume
- 14
- Issue
- 3
- Pages
- 178-187
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2102262668
- Cited by
- 180
- References
- 29
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 6 · 2023: 4 · 2022: 14 · 2021: 6 · 2020: 6 · 2019: 9 · 2018: 9 · 2017: 10 · 2016: 8 · 2015: 4 · 2014: 11 · 2013: 8 · 2012: 13
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Indoor Air (publishedVersion)
- PubMed (publishedVersion)
- Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion)
- Funders
- Teknologi og Produktion, Det Frie Forskningsråd
- Danmarks Tekniske Universitet
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Architecture › Facilities and Workplace Management
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- personal computers, indoor air pollution, sick building syndrome, perceived air quality, office productivity, office ventilation, formaldehyde, toluene, phenols, 2-ethylhexanol, styrene, office workers
- MeSH terms
- Adult, Air Pollutants, Female, Humans, Hydrocarbons, Microcomputers, Perception, Task Performance and Analysis, Air Pollution, Indoor, Sick Building Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review