Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices

Open access
Bako-Biro, Z., Wargocki, P., Weschler, C. J., Fanger, P. O.·2004·Indoor Air

Abstract

UNLABELLED: In groups of six, 30 female subjects were exposed for 4.8 h in a low-polluting office to each of two conditions--the presence or absence of 3-month-old personal computers (PCs). These PCs were placed behind a screen so that they were not visible to the subjects. Throughout the exposure the outdoor air supply was maintained at 10 l/s per person. Under each of the two conditions the subjects performed simulated office work using old low-polluting PCs. They also evaluated the air quality and reported Sick Building Syndrome (SBS) symptoms. The PCs were found to be strong indoor pollution sources, even after they had been in service for 3 months. The sensory pollution load of each PC was 3.4 olf, more than three times the pollution of a standard person. The presence of PCs increased the percentage of people dissatisfied with the perceived air quality from 13 to 41% and increased by 9% the time required for text processing. Chemical analyses were performed to determine the pollutants emitted by the PCs. The most significant chemicals detected included phenol, toluene, 2-ethylhexanol, formaldehyde, and styrene. The identified compounds were, however, insufficient in concentration and kind to explain the observed adverse effects. This suggests that chemicals other than those detected, so-called 'stealth chemicals', may contribute to the negative effects. PRACTICAL IMPLICATIONS: PCs are an important, but hitherto overlooked, source of pollution indoors. They can decrease the perceived air quality, increase SBS symptoms and decrease office productivity. The ventilation rate in an office with a 3-month-old PC would need to be increased several times to achieve the same perceived air quality as in a low-polluting office with the PC absent. Pollution from PCs has an important negative impact on the air quality, not only in offices but also in many other spaces, including homes. PCs may have played a role in previously published studies on SBS and perceived air quality, where PCs were overlooked as a possible pollution source in the indoor environment. The fact that the chemicals identified in the office air and in the chamber experiments were insufficient to explain the adverse effects observed during human exposures illustrates the inadequacy of the analytical chemical methods commonly used in indoor air quality investigations. For certain chemicals the human senses are much more sensitive than the chemical methods routinely used in indoor air quality investigations. The adverse effects of PC-generated air pollutants could be reduced by modifications in the manufacturing process, increased ventilation, localized PC exhaust, or personalized ventilation systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2004.00218.x

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Research works printed but not linked: 16

  1. Black M.S., 1999, Proceedings of Indoor Air '99, 8th International Conference on Indoor Air Quality and Climate, 454
  2. Burr H., 2000, Danskernes anvendelse af computere pa arbejdet 1999
  3. Clements-Croome D., 2001, Proceedings of Clima 2000, 7th REHVA World Congress
  4. Committee on Man and Radiation (COMAR), 1997, IEEE Eng. Med. Biol., 16, 87
  5. Corsi R.L., 2000, Presented Poster: Annual Meeting of the International Society for Exposure Analysis 2000
  6. Funaki R., 2002, Summaries of Technical Papers of Annual Meeting of Architectural Institute of Japan, 863
  7. ISO, 1988, Sensory analysis - Methodology - Ranking Test
  8. ISO, 1993, Sensory Analysis - General Guidance for the Selection, Training and Monitoring of Assessors - Part 1: Selected Assessors
  9. Pejtersen J., 1999, Proceedings of Indoor Air 1999, 160
  10. Salthammer T., 2002, Proceedings of Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate, 213
  11. Skyberg K., 1997, Proceedings of HCI International '97, 7th International Conference on Human-Computer Interaction, 655
  12. TCO '99, 1998, Requirements and Test Methods for Environmental Labelling of Displays (CRT)
  13. Wensing M., 1999, Proceedings of Indoor Air '99, 8th International Conference on Indoor Air Quality and Climate, 87
  14. Wensing M., 2002, Proceedings of Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate, 554
  15. WHO Fact Sheets, 1998, Video Display Units (VDUs) and Human Health
  16. WHO Fact Sheets, 1998, Electromagnetic Fields and Public Health: Extremely low frequency (ELF)

Cited by

Sorted by citations

See all 183

Metadata

Authors
Bako-Biro, Z., Wargocki, P., Weschler, C. J., & Fanger, P. O.
Affiliations
Technical University of Denmark (DK)
Venue
Indoor Air
Published
2004-06
Volume
14
Issue
3
Pages
178-187
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2102262668
Cited by
180
References
29
Citations by year
2026: 1 · 2025: 4 · 2024: 6 · 2023: 4 · 2022: 14 · 2021: 6 · 2020: 6 · 2019: 9 · 2018: 9 · 2017: 10 · 2016: 8 · 2015: 4 · 2014: 11 · 2013: 8 · 2012: 13
FWCI
7.82
Type
journal article
Language
en
Open access
Locations
  • Indoor Air (publishedVersion)
  • PubMed (publishedVersion)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion)
Funders
  • Teknologi og Produktion, Det Frie Forskningsråd
  • Danmarks Tekniske Universitet
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Physical Sciences › Engineering › Architecture › Facilities and Workplace Management
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
personal computers, indoor air pollution, sick building syndrome, perceived air quality, office productivity, office ventilation, formaldehyde, toluene, phenols, 2-ethylhexanol, styrene, office workers
MeSH terms
Adult, Air Pollutants, Female, Humans, Hydrocarbons, Microcomputers, Perception, Task Performance and Analysis, Air Pollution, Indoor, Sick Building Syndrome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review