Cited by 380Indoor Air Quality and Microbial ExposureBuilding Energy and Comfort OptimizationFacilities and Workplace Management

Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance

Open access
Fang, L., Wyon, D. P., Clausen, G., Fanger, P. O.·2004·Indoor Air

Abstract

UNLABELLED: Perceived air quality (PAQ), sick building syndrome (SBS) symptoms and performance of office work were studied in a real office space at three levels of air temperature and humidity and two levels of ventilation rate (20 degrees C/40%, 23 degrees C/50%, 26 degrees C/60% RH at 10 l s(-1) p(-1) outside air, and 20 degrees C/40% RH at 3.5 l s(-1) p(-1) outside air). Thirty female subjects participated in the experiment. They were exposed to each environmental condition for 280 min. Thermal comfort was maintained at different thermal environments by self-adjustment of clothing. The subjects performed simulated office work throughout each exposure and repeatedly marked a set of visual-analog scales to indicate their perception of environmental conditions and of the intensity of SBS symptoms at the time. The study confirmed the previously observed impact of temperature and humidity on perceived air quality and the linear correlation between acceptability and enthalpy. The impact on perceived air quality of decreasing the ventilation rate from 10 to 3.5 l s(-1) per person could be counteracted by a decrement of temperature and humidity from 23 degrees C/50% RH to 20 degrees C/40% RH. Performance of office work was not significantly affected by indoor air temperature and humidity. However, several SBS symptoms were alleviated when the subjects worked at low levels of air temperature and humidity, which implies that a longer term exposure to low indoor air temperature and humidity might help to improve the performance of office work. PRACTICAL IMPLICATIONS: The findings of this study indicate the importance of indoor air temperature and humidity on perceived air quality and SBS symptoms. In practice, the required ventilation rate for comfort and health should no longer be independent of indoor air temperature and humidity.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2004.00276.x

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Indoor air temperature has a great impact on perceived air quality in office buildings, and high air temperatures can promote the generation of VOCs and formaldehyde.

    “Fang et al. [15] indicated that indoor air temperature has great impact on perceived air quality in office buildings, and high air temperatures can promote the generation of other pollutants, such as volatile organic compounds (VOCs) and formaldehyde.”

    From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [15]

    The Results (page not provided) report a significant effect of temperature and humidity on perceived air quality in an office. They do not report that higher temperatures generate VOCs or formaldehyde; the only suggested increase in emissions concerns bioeffluents, and the associated odor increase was not statistically significant. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 5

  1. Bakke, J.V. and Levy, F. (1990) ''Indoor air quality and climate in kindergartens - relation to health effects'', Proceedings of Indoor Air ¢90, Toronto, Canada Mort- gage and Housing Corporation, Ottawa; 1, 3-8.
  2. Berglund, L. and Cain, W.S. (1989) ''Per- ceived air quality and the thermal envi- ronment'', Proceedings of IAQ Ô89, San Diego 345-350
  3. Tanabe, S. (2003) ''Productivity and fati- gue'', Proceedings of the 7th Interna- tional. Conference on Healthy Buildings - Healthy Buildings, 2003, Singapore, 1, 98-103.
  4. Wyon, D.P. (1993) ''Healthy buildings and their impact on productivity'', Proceed- ings of the 6th. International Conference on Indoor Air Quality and Climate -Indoor Air ¢93, Helsinki, 6, 3-13.
  5. Wyon, D.P. (1996) ÔCreative Thinking as the Dependent Variable in Six Environmental Experiments: a ReviewÕ, Proceedings of the 7th International Conference on Indoor Air Quality and Climate -Indoor Air ¢96, Nagoya, Japan, 1, 419-422.

Cited by

Sorted by citations

Authors
Fang, L., Wyon, D. P., Clausen, G., & Fanger, P. O.
Affiliations
Technical University of Denmark (DK)
Corresponding author
Fang, L.
Venue
Indoor Air
Published
2004-08
Volume
14
Issue
s7
Pages
74-81
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2124723332
Cited by
380
References
6
Citations by year
2026: 18 · 2025: 17 · 2024: 31 · 2023: 21 · 2022: 30 · 2021: 34 · 2020: 27 · 2019: 27 · 2018: 30 · 2017: 16 · 2016: 24 · 2015: 16 · 2014: 13 · 2013: 12 · 2012: 14
FWCI
4.69
Type
journal article
Language
en
Open access
Locations
  • Indoor Air (publishedVersion)
  • PubMed (publishedVersion)
  • Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion)
Funders
Teknologi og Produktion, Det Frie Forskningsråd
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Social Sciences › Psychology › Social Psychology › Facilities and Workplace Management
Keywords
indoor temperature, indoor humidity, perceived air quality, ventilation rate, enthalpy, thermal comfort, office occupants
MeSH terms
Adult, Facility Design and Construction, Female, Humans, Humidity, Severity of Illness Index, Task Performance and Analysis, Temperature, Thermosensing, Ventilation, Air Pollution, Indoor, Workplace, Sick Building Syndrome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review