Fungal and endotoxin measurements in dust associated with respiratory symptoms in a water-damaged office building
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
UNLABELLED: We investigated the associations of fungal and endotoxin levels in office dust with respiratory health in 888 (67% participation) occupants of a water-damaged building. We analyzed floor and chair dusts from 338 workstations for culturable fungi and endotoxin. Based on averages, we ranked each floor of the building as low, medium, or high for occupants' exposure to each of these agents. Multivariate logistic regression models for building-related symptoms included this ranking of fungi and endotoxin, age, gender, race, smoking status, and duration of occupancy. Using floor dust measures, we found significantly increased odds for lower respiratory symptoms [wheeze, chest tightness, attacks of shortness of breath, and attacks of cough: odds ratios (OR) = 1.7 (95% confidence interval (CI): 1.02-2.77) to 2.4 (95% CI: 1.29-4.59)], throat irritation [OR = 1.7, (95% CI: 1.06-2.82)], and rash/itchy skin [OR = 3.0, (95% CI: 1.47-6.19)] in the highest fungal exposure group compared to the lowest, with generally linear exposure-response relationships. Nonlinear relationships were observed for many of these symptoms and endotoxin in floor dust. Interaction models showed that endotoxin modified effects of fungi on respiratory symptoms. Our findings of exposure interactions and exposure-response relationships of fungal and endotoxin with increased risk of building-related symptoms contribute to an understanding of the role of microbial agents in building-related asthma and respiratory and systemic symptoms. PRACTICAL IMPLICATIONS: Our demonstration of exposure-response relationships between measurements of fungi and/or endotoxin in floor dusts and building-related symptoms implies that microbial agents in floor dust may be a good surrogate measure for dampness-related bioaerosol exposure, considering that measurements of microbial agents in air often fail to demonstrate the associations between exposure and health. In addition, our finding that endotoxin exposure may change the effect of fungal exposure (and vice versa) on respiratory heath suggests that exposure to both fungi and endotoxin should be assessed in epidemiological investigations examining the effect of fungal or endotoxin exposure on respiratory health in indoor environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of Average Concentration in the Presence of Nondetectable Values
Hornung, R. W., & Reed, L. D. (1990) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1990.10389587 · Cited by 3,495
Chew, G. L., Rogers, C., Burge, H. A., Muilenberg, M. L., & Gold, D. R. (2003) · Allergy · doi:10.1034/j.1398-9995.2003.00013.x · Cited by 175
Cited by
Mendell, M. J., Mirer, A. G., Cheung, K., Tong, M., & Douwes, J. (2011) · Environmental Health Perspectives · doi:10.1289/ehp.1002410 · Cited by 986
Public health and economic impact of dampness and mold
Mudarri, D., & Fisk, W. J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00474.x · Cited by 319
Keall, M. D., Crane, J., Baker, M. G., Wickens, K., Howden-Chapman, P., & Cunningham, M. (2012) · Environmental Health · doi:10.1186/1476-069x-11-33 · Cited by 64
Microbial hazards during harvesting and processing at an outdoor United States cannabis farm
Green, B. J., Couch, J. R., Lemons, A. R., Burton, N. C., Victory, K. R., Nayak, A. P., & Beezhold, D. H. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1432863 · Cited by 43
Huang, H.-C., Zou, M.-L., Chen, Y.-H., Jiang, C.-B., Wu, C.-D., Lung, S.-C. C., Chien, L.-C., Lo, Y.-C., & Chao, H. J. (2023) · Science of The Total Environment · doi:10.1016/j.scitotenv.2023.165392 · Cited by 26
Metadata
- Authors
- Park, J.-H., Cox-Ganser, J., Rao, C., & Kreiss, K.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2006-06
- Volume
- 16
- Issue
- 3
- Pages
- 192-203
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2154205887
- Cited by
- 101
- References
- 2
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fungal and endotoxin measurements in dust associated with respiratory symptoms in a water-damaged office building. https://app.cochat.ai/papers/10.1111/j.1600-0668.2005.00415.x
- The paper
- Park, J.-H., Cox-Ganser, J., Rao, C., & Kreiss, K. (2006). Fungal and endotoxin measurements in dust associated with respiratory symptoms in a water-damaged office building. Indoor Air. https://doi.org/10.1111/j.1600-0668.2005.00415.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.