CoChat

Field study of a thermal environment and adaptive model in Shanghai

Open access
Ye, X. J., Zhou, Z. P., Lian, Z. W., Liu, H. M., Li, C. Z., Liu, Y. M. · 2006 · Indoor Air
Cited by 122

The DOI matches its Crossref record.

Abstract

A long-term field investigation was carried out in naturally ventilated residential buildings in Shanghai from April 2003 to November 2004. A total of 1,768 returned questionnaires were collected in the study. This study deals with the thermal sensation of occupants in naturally ventilated buildings and the change in thermal neutral temperature with season. The range of accepted temperature in naturally ventilated buildings is between 14.7 degrees C T(op) and 29.8 degrees C T(op). The results also report the findings of the adaptive comfort model in Shanghai that determines the adaptive relationship of neutral temperature with outdoor air temperature. A long-term field study was carried out in residential buildings in Shanghai to find the relationship between thermal sensation, indoor neutral temperature and outdoor temperature. This paper presents findings of thermal comfort and discusses the more sustainable standard for the indoor climate of residential buildings in Shanghai.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2006.00434.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Ye, X. J., Zhou, Z. P., Lian, Z. W., Liu, H. M., Li, C. Z., & Liu, Y. M.
Venue
Indoor Air
Published
2006-08
Volume
16
Issue
4
Pages
320-326
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2056226244
Cited by
122
References
0
FWCI
10.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.