Outdoor ozone and building-related symptoms in the BASE study
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Reactions between ozone and indoor contaminants may influence human health and indoor air quality. The U.S. EPA Building Assessment Survey and Evaluation (BASE) study data were analyzed for associations between ambient ozone concentrations and building-related symptom (BRS) prevalence. Multiple logistic regression (MLR) models, adjusted for personal, workplace, and environmental variables, revealed positive relationships (P < 0.05) between ambient ozone concentrations and upper respiratory (UR), dry eyes, neurological and headache BRS (odds ratios ranged from 1.03 to 1.04 per 10 mug/m(3) increase in ambient ozone concentrations). Other BRS had marginally significant relationships with ambient ozone (P < 0.10). A linear dose-response in UR symptoms was observed with increasing ambient ozone (P = 0.03); most other symptoms showed similar but not statistically significant trends. Ambient ozone correlated with indoor concentrations of some aldehydes, a pattern suggesting the occurrence of indoor ozone chemistry. Coupled with the MLR ambient ozone-BRS analysis, this correlation is consistent with the hypothesis that ozone-initiated indoor reactions play an important role in indoor air quality and building occupant health. Replication with increased statistical power and with longitudinal data is needed. If the observed associations are confirmed as causal, ventilation system ozone removal technologies could reduce UR BRS prevalence when higher ambient ozone levels are present. PRACTICAL IMPLICATIONS: This paper provides strong statistical evidence that supports (but does not prove) the hypothesis that ozone entrained into buildings from the outdoor air is involved in increasing the frequency that occupants experience and a range of upper and lower respiratory, mucosal and neurological symptoms by as much as a factor of 2 when ambient ozone levels increase from those found in low-ozone regions to those typical of high-ozone regions. Although replication is needed, the implication is that reducing the amount of ozone entrained into building ventilation systems, either by ambient pollution reduction or engineered gas-phase filtration, may substantially reduce the prevalence of these symptoms experienced by occupants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationBell, M. L., Peng, R. D., & Dominici, F. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.8816 · Cited by 481
Cogliano, V. J., Grosse, Y., Baan, R. A., Straif, K., Secretan, M. B., Ghissassi, F. E., & the Working Group for Volume 88 (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7542 · Cited by 375
Wolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348
Erdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147
Self-citation
Cited by
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Catalytic decomposition of gaseous ozone over manganese dioxides with different crystal structures
Jia, J., Zhang, P., & Chen, L. (2016) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2016.02.055 · Cited by 605
Tham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
Indoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
Climate Change and Occupational Safety and Health: Establishing a Preliminary Framework
Schulte, P. A., & Chun, H. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903066008 · Cited by 206
Metadata
- Authors
- Apte, M. G., Buchanan, I. S. H., & Mendell, M. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2008-04
- Volume
- 18
- Issue
- 2
- Pages
- 156-170
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2001404943
- Cited by
- 73
- References
- 5
- FWCI
- 3.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.