Quantitative relationship of sick building syndrome symptoms with ventilation rates
Abstract
UNLABELLED: Data from published studies were combined and analyzed to develop best-fit equations and curves quantifying the change in sick building syndrome (SBS) symptom prevalence in office workers with ventilation rate. For each study, slopes were calculated, representing the fractional change in SBS symptom prevalence per unit change in ventilation rate per person. Values of ventilation rate, associated with each value of slope, were also calculated. Linear regression equations were fitted to the resulting data points, after weighting by study size. Integration of the slope-ventilation rate equations yielded curves of relative SBS symptom prevalence vs. ventilation rate. Based on these analyses, as the ventilation rate drops from 10 to 5 l/s-person, relative SBS symptom prevalence increases approximately 23% (12% to 32%), and as ventilation rate increases from 10 to 25 l/s-person, relative prevalence decreases approximately 29% (15% to 42%). Variations in SBS symptom types, building features, and outdoor air quality may cause the relationship of SBS symptom prevalence with ventilation rate in specific situations to differ from the average relationship predicted in this paper. PRACTICAL IMPLICATIONS: On average, providing more outdoor air ventilation will reduce prevalence rates of sick building syndrome (SBS) symptoms. However, given the costs of energy use, including increased risks of climate change, it is important to balance the benefits and risks of increased ventilation. This paper provides initial estimates of how the incremental health benefits per unit of increased ventilation diminish at higher levels of ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 6×
“…prior critical reviews of the literature have concluded that lower ventilation rates are associated with higher SBS symptom prevalence rates (Seppanen et al. 1999; Wargocki et al. 2002), to the best of our knowledge this paper presents the first systematic analyses of published data to…”
BackgroundResultInfluentialSelf-citation
Cited by
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Self-citationTen questions concerning well-being in the built environment
Altomonte, S., Allen, J., Bluyssen, P. M., Brager, G., Heschong, L., Loder, A., Schiavon, S., Veitch, J. A., Wang, L., & Wargocki, P. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106949 · Cited by 303
Metadata
- Authors
- Fisk, W. J., Mirer, A. G., & Mendell, M. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2009-04
- Volume
- 19
- Issue
- 2
- Pages
- 159-165
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2128282682
- Cited by
- 196
- References
- 1
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative relationship of sick building syndrome symptoms with ventilation rates. https://app.cochat.ai/papers/10.1111/j.1600-0668.2008.00575.x
- The paper
- Fisk, W. J., Mirer, A. G., & Mendell, M. J. (2009). Quantitative relationship of sick building syndrome symptoms with ventilation rates. Indoor Air. https://doi.org/10.1111/j.1600-0668.2008.00575.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.