Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Quantitative relationship of sick building syndrome symptoms with ventilation rates

Fisk, W. J., Mirer, A. G., Mendell, M. J.·2009·Indoor Air

Abstract

UNLABELLED: Data from published studies were combined and analyzed to develop best-fit equations and curves quantifying the change in sick building syndrome (SBS) symptom prevalence in office workers with ventilation rate. For each study, slopes were calculated, representing the fractional change in SBS symptom prevalence per unit change in ventilation rate per person. Values of ventilation rate, associated with each value of slope, were also calculated. Linear regression equations were fitted to the resulting data points, after weighting by study size. Integration of the slope-ventilation rate equations yielded curves of relative SBS symptom prevalence vs. ventilation rate. Based on these analyses, as the ventilation rate drops from 10 to 5 l/s-person, relative SBS symptom prevalence increases approximately 23% (12% to 32%), and as ventilation rate increases from 10 to 25 l/s-person, relative prevalence decreases approximately 29% (15% to 42%). Variations in SBS symptom types, building features, and outdoor air quality may cause the relationship of SBS symptom prevalence with ventilation rate in specific situations to differ from the average relationship predicted in this paper. PRACTICAL IMPLICATIONS: On average, providing more outdoor air ventilation will reduce prevalence rates of sick building syndrome (SBS) symptoms. However, given the costs of energy use, including increased risks of climate change, it is important to balance the benefits and risks of increased ventilation. This paper provides initial estimates of how the incremental health benefits per unit of increased ventilation diminish at higher levels of ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2008.00575.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 196

Metadata

Authors
Fisk, W. J., Mirer, A. G., & Mendell, M. J.
Venue
Indoor Air
Published
2009-04
Volume
19
Issue
2
Pages
159-165
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2128282682
Cited by
196
References
1
FWCI
5.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative relationship of sick building syndrome symptoms with ventilation rates. https://app.cochat.ai/papers/10.1111/j.1600-0668.2008.00575.x
The paper
Fisk, W. J., Mirer, A. G., & Mendell, M. J. (2009). Quantitative relationship of sick building syndrome symptoms with ventilation rates. Indoor Air. https://doi.org/10.1111/j.1600-0668.2008.00575.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.