CoChat

The influence of chemical interactions at the human surface on breathing zone levels of reactants and products

Open access
Rim, D., Novoselec, A., Morrison, G. · 2009 · Indoor Air
Cited by 70

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Using computational fluid dynamics simulations of an occupant in a ventilated room, we find that breathing zone ozone levels can be substantially lower and ozone reaction products associated with human surfaces (ORPHS) levels considerably higher than room levels. For air exchange rates <3/h, the ratio of the breathing zone to the ozone concentration 1 m from the body (bulk air), r(ozone), ranges from 0.59 to 0.75 for floor or ceiling air supply. ORPHS are enriched in the breathing zone, with concentrations for these conditions ranging from 1.2 to 2.5 greater than bulk air concentrations. At high air exchange rates (>8/h), the breathing zone concentrations approach bulk air concentrations (r(ozone) > 0.9) with a floor supply, whereas large concentration gradients occur between breathing zone and bulk air with a ceiling supply. At these high air exchange rates, ORPHS levels are 1.6-2.0 and 2.9-6.0 times the bulk air concentrations for floor and ceiling supply, respectively. The extent of depletion of ozone or enrichment of ORPHS is large enough that reliance on micro-environmental measurements alone, to assess the intake of ozone or ORPHS, is undesirable. PRACTICAL IMPLICATIONS: Chemical reactions between ozone and human and clothing surfaces are predicted to significantly reduce ozone concentrations, and increase ozone reaction products associated with human surfaces (ORPHS) concentrations, in the breathing zone, relative to those concentrations in the larger microenvironment of a room. Existing measurements may overestimate ozone exposure and intake in typical indoor environments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2009.00595.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 70

Metadata

Authors
Rim, D., Novoselec, A., & Morrison, G.
Venue
Indoor Air
Published
2009-08
Volume
19
Issue
4
Pages
324-334
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2114508551
Cited by
70
References
3
FWCI
1.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The influence of chemical interactions at the human surface on breathing zone levels of reactants and products. https://app.cochat.ai/papers/10.1111/j.1600-0668.2009.00595.x
The paper
Rim, D., Novoselec, A., & Morrison, G. (2009). The influence of chemical interactions at the human surface on breathing zone levels of reactants and products. Indoor Air. https://doi.org/10.1111/j.1600-0668.2009.00595.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.