Ultrafine particle concentrations and exposures in seven residences in northern California: Residential exposures to ultrafine particles
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Human exposures to ultrafine particles (UFP) are poorly characterized given the potential associated health risks. Residences are important sites of exposure. To characterize residential exposures to UFP in some circumstances and to investigate governing factors, seven single-family houses in California were studied during 2007-2009. During multiday periods, time-resolved particle number concentrations were monitored indoors and outdoors and information was acquired concerning occupancy, source-related activities, and building operation. On average, occupants were home for 70% of their time. The geometric mean time-average residential exposure concentration for 21 study subjects was 14,500 particles per cm(3) (GSD = 1.8; arithmetic mean ± standard deviation = 17,000 ± 10,300 particles per cm(3)). The average contribution to residential exposures from indoor episodic sources was 150% of the contribution from particles of outdoor origin. Unvented natural-gas pilot lights contributed up to 19% to exposure for the two households where present. Episodic indoor source activities, most notably cooking, caused the highest peak exposures and most of the variation in exposure among houses. Owing to the importance of indoor sources and variations in the infiltration factor, residential exposure to UFP cannot be characterized by ambient measurements alone. PRACTICAL IMPLICATIONS: Indoor and outdoor sources each contribute to residential ultrafine particle (UFP) concentrations and exposures. Under the conditions investigated, peak exposure concentrations indoors were associated with cooking, using candles, or the use of a furnace. Active particle removal systems can mitigate exposure by reducing the persistence of particles indoors. Eliminating the use of unvented gas pilot lights on cooking appliances could also be beneficial. The study results indicate that characterization of human exposure to UFP, an air pollutant of emerging public health concern, cannot be accomplished without a good understanding of conditions inside residences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toxic potential of materials at the nanolevel
Nel, A., Xia, T., Mädler, L., & Li, N. (2006) · Science · doi:10.1126/science.1114397 · Cited by 9,324
Health Effects of Fine Particulate Air Pollution: Lines that Connect
Pope, C. A., & Dockery, D. W. (2006) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2006.10464485 · Cited by 6,583
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803
Formation and growth rates of ultrafine atmospheric particles: a review of observations
Kulmala, M., Vehkamäki, H., Petäjä, T., Dal Maso, M., Lauri, A., Kerminen, V.-M., Birmili, W., & McMurry, P. H. (2004) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2003.10.003 · Cited by 2,191
Delfino, R. J., Sioutas, C., & Malik, S. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7938 · Cited by 931
Study of ultrafine particles near a major highway with heavy-duty diesel traffic
Zhu, Y., Hinds, W. C., Kim, S., Shen, S., & Sioutas, C. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00354-0 · Cited by 919
Nazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
Self-citationContribution from indoor sources to particle number and mass concentrations in residential houses
HE, C. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.03.027 · Cited by 585
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Self-citationRelative contribution of outdoor and indoor particle sources to indoor concentrations
Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P. (2000) · Environmental Science & Technology · doi:10.1021/es990348y · Cited by 411
Cited by
Indoor Exposure to Selected Air Pollutants in the Home Environment: A Systematic Review
Vardoulakis, S., Giagloglou, E., Steinle, S., Davis, A., Sleeuwenhoek, A., Galea, K. S., Dixon, K., & Crawford, J. O. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17238972 · Cited by 545
“In a study in California, USA, cooking caused the highest indoor UFP exposures [46].”
BackgroundIndoor aerosols: from personal exposure to risk assessment
Morawska, L., Afshari, A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E. R., Pasanen, P., et al. (2013) · Indoor Air · doi:10.1111/ina.12044 · Cited by 442
SVOC exposure indoors: fresh look at dermal pathways: SVOC exposure via dermal pathways
Weschler, C. J., & Nazaroff, W. W. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00772.x · Cited by 422
Self-citationAzimi, P., Zhao, D., Pouzet, C., Crain, N. E., & Stephens, B. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.5b04983 · Cited by 389
Weschler, C. J., & Carslaw, N. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.7b06387 · Cited by 293
Logue, J. M., McKone, T. E., Sherman, M. H., & Singer, B. C. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00683.x · Cited by 266
Concentrations of fine, ultrafine, and black carbon particles in auto-rickshaws in New Delhi, India
Apte, J. S., Kirchstetter, T. W., Reich, A. H., Deshpande, S. J., Kaushik, G., Chel, A., Marshall, J. D., & Nazaroff, W. W. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2011.05.028 · Cited by 224
Self-citationWildfire smoke impacts on indoor air quality assessed using crowdsourced data in California
Liang, Y., Sengupta, D., Campmier, M. J., Lunderberg, D. M., Apte, J. S., & Goldstein, A. H. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2106478118 · Cited by 205
Growth of organic films on indoor surfaces
Weschler, C. J., & Nazaroff, W. W. (2017) · Indoor Air · doi:10.1111/ina.12396 · Cited by 188
Self-citationEstimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin
Azimi, P., Zhao, D., & Stephens, B. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.09.007 · Cited by 172
“However, the majority of exposure to fine and ultrafine particles of outdoor origin often occurs inside buildings (Allen et al., 2004; Bhangar et al., 2011; Kearney et al., 2011; Meng et al., 2009, 2005).”
BackgroundSinger, B. C., Pass, R. Z., Delp, W. W., Lorenzetti, D. M., & Maddalena, R. L. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.021 · Cited by 162
Mullen, N. A., Bhangar, S., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00690.x · Cited by 90
Self-citation
Metadata
- Authors
- Bhangar, S., Mullen, N. A., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2010-10-28
- Volume
- 21
- Issue
- 2
- Pages
- 132-144
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2113289029
- Cited by
- 158
- References
- 34
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.