Cited by 187Thermoregulation and physiological responsesBuilding Energy and Comfort OptimizationPhase Change Materials Research

Personal cooling with phase change materials to improve thermal comfort from a heat wave perspective: Phase change materials to improve thermal comfort

Open access
Gao, C., Kuklane, K., Wang, F., Holmér, I.·2012·Indoor Air

Abstract

UNLABELLED: The impact of heat waves arising from climate change on human health is predicted to be profound. It is important to be prepared with various preventive measures for such impacts on society. The objective of this study was to investigate whether personal cooling with phase change materials (PCM) could improve thermal comfort in simulated office work at 34°C. Cooling vests with PCM were measured on a thermal manikin before studies on human subjects. Eight male subjects participated in the study in a climatic chamber (T(a) = 34°C, RH = 60%, and ν(a) = 0.4 m/s). Results showed that the cooling effect on the manikin torso was 29.1 W/m(2) in the isothermal condition. The results on the manikin using a constant heating power mode reflect directly the local cooling effect on subjects. The results on the subjects showed that the torso skin temperature decreased by about 2-3°C and remained at 33.3°C. Both whole body and torso thermal sensations were improved. The findings indicate that the personal cooling with PCM can be used as an option to improve thermal comfort for office workers without air conditioning and may be used for vulnerable groups, such as elderly people, when confronted with heat waves. PRACTICAL IMPLICATIONS: Wearable personal cooling integrated with phase change materials has the advantage of cooling human body's micro-environment in contrast to stationary personalized cooling and entire room or building cooling, thus providing greater mobility and helping to save energy. In places where air conditioning is not usually used, this personal cooling method can be used as a preventive measure when confronted with heat waves for office workers, vulnerable populations such as the elderly and disabled people, people with chronic diseases, and for use at home.

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2012.00778.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Gao, C., Kuklane, K., Wang, F., & Holmér, I.
Affiliations
Lund University (SE)
Corresponding author
Gao, C.
Venue
Indoor Air
Publisher
Wiley
Published
2012-03-20
Volume
22
Issue
6
Pages
523-530
ISSN
0905-6947 (ISSN-L)
OpenAlex
W2162070364
Cited by
187
References
5
Citations by year
2026: 8 · 2025: 10 · 2024: 14 · 2023: 26 · 2022: 25 · 2021: 15 · 2020: 17 · 2019: 11 · 2018: 14 · 2017: 17 · 2016: 10 · 2015: 9 · 2014: 7 · 2013: 3 · 2012: 1
FWCI
4.28
Type
journal article
Language
en
Open access
Locations
  • Indoor Air (publishedVersion)
  • PubMed (publishedVersion)
  • Lund University Publications (Lund University) (submittedVersion)
Funders
VINNOVA
Topics
  • Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
Keywords
personal cooling, phase change materials, thermal comfort, heat waves, cooling vest, thermal manikin, thermal sensation, office workers, older adults, climate change, heat stress prevention
MeSH terms
Adult, Humans, Infrared Rays, Male, Manikins, Protective Clothing, Skin Temperature, Heat Stress Disorders, Climate Change

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review