Skin biomechanical properties: in vivo evaluation of influence of age and body site by a non‐invasive method
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background/aims: Biomechanical properties of the skin are evaluated in vivo by torsion or extension methods. We assessed their modifications as function of age, probe diameter and regional body site. Methods: For measuring skin extensibility (or traction), we used a non‐invasive suction device on a total of 37 volunteers, consisting of (A) 14 younger women (30.1±7.6 years) and (B) 23 older women (60.2±6.5 years). Measurements were performed on three different areas with 4 different probe diameters. The parameters used were (UE) extensibility; (UV) plasticity; (UR) tonicity; (URUE) elasticity; the difference between the lowest point of the last curve (5th) and that of the 1st is the fatiguability. Concurrently, we measured on each volunteer the microdepressionary network (mDN) length. Results: Generally, tonicity, extensibility and elasticity decreased; fatiguability increased and plasticity stayed the same; all of these factors apply regardless of age. Results are more homogenous on the volar face of the forearm and with 2, 4 and 6 mm probe diameters. As a general trend, mDN length decreases with age. Conclusions: The knowledge of this variation is important in interpreting the results obtained after product application. Standardisation of measures with the 2‐mm probe will allow product efficacy determination and the comparison of different products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In Vivo Studies of the Evolution of Physical Properties of the Human Skin with Age
Leveque, J. L., Corcuff, P., Rigal, J. D., & Agache, P. (1984) · International Journal of Dermatology · doi:10.1111/j.1365-4362.1984.tb04061.x · Cited by 199 · cited 1×
“(15), the decrease in intrinsic extensibility might be due to the collapse and the density increase of collagen fibers which are not extending with age.”
Background
Cited by
Skin ageing: changes of physical properties of human skin in vivo
Diridollou, S., Vabre, V., Berson, M., Vaillant, L., Black, D., Lagarde, J. M., Grégoire, J. M., Gall, Y., & Patat, F. (2001) · International Journal of Cosmetic Science · doi:10.1046/j.0412-5463.2001.00105.x · Cited by 178
Sex‐ and site‐dependent variations in the thickness and mechanical properties of human skin in vivo
Diridollou, S., Black, D., Lagarde, J. M., Gall, Y., Berson, M., Vabre, V., Patat, F., & Vaillant, L. (2000) · International Journal of Cosmetic Science · doi:10.1111/j.1468-2494.2000.00037.x · Cited by 99
Piérard‐Franchimont, C., Castelli, D., Cromphaut, I. V., Bertin, C., Ries, G., Cauwenbergh, G., & Piérard, G. E. (1998) · Skin Research and Technology · doi:10.1111/j.1600-0846.1998.tb00116.x · Cited by 36
Metadata
- Authors
- Couturaud, V., Coutable, J., & Khaiat, A.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 1995-05
- Volume
- 1
- Issue
- 2
- Pages
- 68-73
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2099749843
- Cited by
- 44
- References
- 1
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Skin biomechanical properties: in vivo evaluation of influence of age and body site by a non‐invasive method. https://app.cochat.ai/papers/10.1111/j.1600-0846.1995.tb00020.x
- The paper
- Couturaud, V., Coutable, J., & Khaiat, A. (1995). Skin biomechanical properties: in vivo evaluation of influence of age and body site by a non‐invasive method. Skin Research and Technology. https://doi.org/10.1111/j.1600-0846.1995.tb00020.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.