C4d Fixing, Luminex Binding Antibodies—A New Tool for Prediction of Graft Failure After Heart Transplantation
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The standard method to detect pretransplant antibodies has been the complement dependent cytotoxicity (CDC) test of donor leukocytes. Solid phase assays to detect HLA antibodies in pretransplant serum reveal a greater number of sensitized patients, but their clinical impact is less certain. Here we have developed a method of detecting C4d fixing HLA antibodies on Luminex beads. Pretransplant serum from 565 cardiac transplant patients was retrospectively tested for the presence of HLA antibodies using CDC, HLA coated Luminex beads and C4d deposition on Luminex beads, and the results correlated with graft survival. Whereas 5/565 patients had CDC positive donor specific antibodies (DSA) before their transplant, this number was increased by 19 using Luminex beads. The 1-year survival of CDC -ve/Luminex +ve patients with DSA (n = 19) was 42% compared with 77% for CDC -ve/Luminex +ve without DSA (n = 39, p = 0.0039). Fixation of C4d (22/67 Luminex positive sera) had a negative effect on graft outcome; 1-year graft survival was, C4d +ve/DSA +ve (n = 11) 20%, C4d +ve/DSA -ve (n = 11) 91%, C4d -ve DSA +ve (n = 13) 54%, C4d -ve DSA -ve (n = 32) 75%, compared with 75% for antibody-negative patients (p = 0.0002). In conclusion, detection of Luminex +ve DSA in pretransplant serum provides a powerful negative predictor of graft survival, especially if they bind C4d.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microdroplet Assay of Human Serum Cytotoxins
TERASAKI, P. I., & McCLELLAND, J. D. (1964) · Nature · doi:10.1038/204998b0 · Cited by 2,060 · cited 1×
“Until recently, the gold standard method to test for preformed antibodies was the complement dependent cytotoxicity assay (CDC); this assay consists of incubating leukocytes from the prospective donor with serum from the recipient in the presence of rabbit complement and determining leukocyte survival (3).”
MethodSignificance of the Positive Crossmatch Test in Kidney Transplantation
Patel, R., & Terasaki, P. I. (1969) · New England Journal of Medicine · doi:10.1056/nejm196904032801401 · Cited by 1,508 · cited 2×
“Preformed antibodies to graft antigens is a major risk factor for rapid humoral rejection after renal (1) and heart or lung transplantation (2).”
BackgroundBo[Combining Diaeresis]hmig, G. A., Exner, M., Habicht, A., Schillinger, M., Lang, U., Kletzmayr, J., Sa[Combining Diaeresis]emann, M. D., Ho[Combining Diaeresis]rl, W. H., Watschinger, B., & Regele, H. (2002) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1341091 · Cited by 340
COMPLEMENT IN ORGAN TRANSPLANTATION CONTRIBUTIONS TO INFLAMMATION, INJURY, AND REJECTION
BALDWIN, W. M., PRUITT, S. K., BRAUER, R. B., DAHA, M. R., & SANFILIPPO, F. (1995) · Transplantation · doi:10.1097/00007890-199503000-00001 · Cited by 194
Rodriguez, E. R., Skojec, D. V., Tan, C. D., Zachary, A. A., Kasper, E. K., Conte, J. V., & Baldwin, W. M. (2005) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2005.01074.x · Cited by 162
Pretransplant Risk Assessment in Renal Allograft Recipients Using Virtual Crossmatching
Bielmann, D., Hönger, G., Lutz, D., Mihatsch, M., Steiger, J., & Schaub, S. (2007) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2007.01667.x · Cited by 152 · cited 2×
“Should these patients be transplanted, they would require close monitoring and perhaps augmented immunosuppression (10).”
BackgroundSmith, J. D., Danskine, A. J., Laylor, R. M., Rose, M. L., & Yacoub, M. H. (1993) · Transplant Immunology · doi:10.1016/0966-3274(93)90060-l · Cited by 137 · cited 2×
“Preformed antibodies to graft antigens is a major risk factor for rapid humoral rejection after renal (1) and heart or lung transplantation (2).”
BackgroundSelf-citationGibney, E. M., Cagle, L. R., Freed, B. M., Warnell, S. E., Chan, L., & Wiseman, A. C. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfl202 · Cited by 117 · cited 3×
“These assays cannot distinguish between complement fixing and noncomplement fixing antibodies, so it is not surprising that they detect many more sensitized patients than the CDC assay (8,9); this brings into question whether it is safe to transplant patients who may be CDC negative but positive for HLA antigens detec…”
BackgroundWahrmann, M., Exner, M., Haidbauer, B., Schillinger, M., Regele, H. M., Körmöczi, G. F., & Böhmig, G. A. (2005) · Human Immunology · doi:10.1016/j.humimm.2004.12.007 · Cited by 51
Cited by
Costanzo, M. R., Costanzo, M. R., Dipchand, A., Starling, R., Anderson, A., Chan, M., Desai, S., Fedson, S., Fisher, P., Gonzales-Stawinski, G., et al. (2010) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2010.05.034 · Cited by 1,653
Self-citationTait, B. D., Süsal, C., Gebel, H. M., Nickerson, P. W., Zachary, A. A., Claas, F. H. J., Reed, E. F., Bray, R. A., Campbell, P., Chapman, J. R., et al. (2013) · Transplantation · doi:10.1097/tp.0b013e31827a19cc · Cited by 787
Diagnosis and Management of Antibody-Mediated Rejection: Current Status and Novel Approaches
Djamali, A., Kaufman, D. B., Ellis, T. M., Zhong, W., Matas, A., & Samaniego, M. (2014) · American Journal of Transplantation · doi:10.1111/ajt.12589 · Cited by 369
Ciurea, S. O., de Lima, M., Cano, P., Korbling, M., Giralt, S., Shpall, E. J., Wang, X., Thall, P. F., Champlin, R. E., & Fernandez-Vina, M. (2009) · Transplantation · doi:10.1097/tp.0b013e3181b9d710 · Cited by 287
Sicard, A., Ducreux, S., Rabeyrin, M., Couzi, L., McGregor, B., Badet, L., Scoazec, J. Y., Bachelet, T., Lepreux, S., Visentin, J., et al. (2015) · Journal of the American Society of Nephrology · doi:10.1681/asn.2013101144 · Cited by 276
Metadata
- Authors
- Smith, J. D., Hamour, I. M., . Banner, N. R., & Rose, M. L.
- Venue
- American Journal of Transplantation
- Publisher
- Elsevier BV
- Published
- 2007-12
- Volume
- 7
- Issue
- 12
- Pages
- 2809-2815
- ISSN
- 1600-6135 (ISSN-L)
- OpenAlex
- W1999330956
- Cited by
- 165
- References
- 9
- FWCI
- 14.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.