Tissue engineering of bone: search for a better scaffold

Open access
Mastrogiacomo, M, Muraglia, A, Komlev, V, Peyrin, F, Rustichelli, F, Crovace, A, Cancedda, R · 2005 · Orthodontics & Craniofacial Research

Abstract

Structured Abstract: Authors – Mastrogiacomo M, Muraglia A, Komlev V, Peyrin F, Rustichelli F, Crovace A, Cancedda R Background – Large bone defects still represent a major problem in orthopedics. Traditional bone‐repair treatments can be divided into two groups: the bone transport (Ilizarov technology) and the graft transplant (autologous or allogeneic bone grafts). Thus far, none of these strategies have proven to be always resolving. As an alternative, a tissue engineering approach has been proposed where osteogenic cells, bioceramic scaffolds, growth factors and physical forces concur to the bone defect repair. Different sources of osteoprogenitor cells have been suggested, bone marrow stromal cells (BMSC) being in most cases the first choice. Methods and Results – In association with mineral tridimensional scaffolds, BMSC form a primary bone tissue which is highly vascularized and colonized by host hemopoietic marrow. The chemical composition of the scaffold is crucial for the osteoconductive properties and the resorbability of the material. In addition, scaffolds should have an internal structure permissive for vascular invasion. Porous bioceramics [hydroxyapatite (HA) and tricalcium phosphate] are osteoconductive and are particularly advantageous for bone tissue engineering application as they induce neither an immune nor an inflammatory response in the implanted host. Earlier, we first reported a cell‐based tissue engineering procedure to treat three patients with long bone segmental defects. Cells were loaded on a 100% HA porous ceramic. These scaffolds proved to have good osteoconductive properties resulting in a good functional recovery, but they have not been resorbed after more than 5 years from the implant. In addition, due to the high density of the mineral and the relatively low porosity (50–60%), it was very difficult to monitor the patient recovery during the post‐surgery time using X‐rays. Conclusions – We report here some pre‐clinical testing of new scaffolds. To compare these second generation ceramic scaffolds more suitable for a tissue engineering approach we had to first establish animal models and analysis procedures including the use of X‐ray‐computed microtomography associated with X‐rays synchroton radiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1601-6343.2005.00350.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 250

Metadata

Authors
Mastrogiacomo, M., Muraglia, A., Komlev, V, Peyrin, F., Rustichelli, F., Crovace, A., & Cancedda, R.
Venue
Orthodontics & Craniofacial Research
Publisher
Wiley
Published
2005-10-18
Volume
8
Issue
4
Pages
277-284
ISSN
  • 1601-6335 (ISSN-L)
  • 1601-6343
OpenAlex
W1970521704
Cited by
250
References
1
FWCI
10.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tissue engineering of bone: search for a better scaffold. https://app.cochat.ai/papers/10.1111/j.1601-6343.2005.00350.x
The paper
Mastrogiacomo, M., Muraglia, A., Komlev, V, Peyrin, F., Rustichelli, F., Crovace, A., & Cancedda, R. (2005). Tissue engineering of bone: search for a better scaffold. Orthodontics & Craniofacial Research. https://doi.org/10.1111/j.1601-6343.2005.00350.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.