The DOI matches its Crossref record.
The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants: Primary Stability of Dental Implant
Abstract
BACKGROUND: Primary implant stability has been used as an indicator for future osseointegration and whether an immediate/early loading protocol should be applied. Implant stability is the key to clinical success. PURPOSE: The aim of this work was to analyze the influence of the design and surface morphology on the primary stability of dental implants. The insertion torque and resonance frequency analysis (RFA) were the parameters used to measure the primary stability of the implants. MATERIALS AND METHODS: Thirty implants, divided in six groups of five samples were placed in cylinder of high molecular weight polyethylene. The groups were different upon two designs (cylindrical and conic) and three implant surfaces finishing (machined, acid etched, and anodized). The insertion torque was quantified by a digital torque driver (Lutron Electronic Enterprise Co., Taipei, Taiwan) and the resonance frequency was measured by Osstell mentor™ (Integration Diagnostics AB, Göteborg, Sweden). The implant surface morphology was characterized by scanning electron microscopy, roughness measurement, and friction coefficient. RESULTS: The machined implants showed smaller insertion torques than treated implant surfaces. There were no differences between the RFA measurements in all tested surfaces. Statistical analyses demonstrated no correlation between the dental implant insertion torque and primary stability measured by the RFA. The implants with treated surfaces showed greater roughness, a higher friction coefficient, and demanded a larger insertion torque than machined implants. The results of the surface roughness and friction coefficients are in accordance with the results of the insertion torque. The difference, across the insertion torque values, between conical and cylindrical implants, can be explained by the different contact surface area among the thread geometry of these implants. CONCLUSION: The maximum implant insertion torque depends on the implant geometry, thread form, and implant surface morphology. The placement of conical implants with treated surfaces required the highest insertion torque. There was no correlation between RFA and insertion torque implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rao, P. J., Pelletier, M. H., Walsh, W. R., & Mobbs, R. J. (2014) · Orthopaedic Surgery · doi:10.1111/os.12098 · Cited by 285
Effects of Titanium Surfaces on the Developmental Profile of Monocytes/Macrophages
Moura, C. C. G., Zanetta-Barbosa, D., Dechichi, P., Carvalho, V. F., & Soares, P. B. F. (2014) · Brazilian Dental Journal · doi:10.1590/0103-6440201302260 · Cited by 10
Metadata
- Authors
- dos Santos, M. V., Elias, C. N., & Cavalcanti Lima, J. H.
- Venue
- Clinical Implant Dentistry and Related Research
- Publisher
- Wiley
- Published
- 2009-09-09
- Volume
- 13
- Issue
- 3
- Pages
- 215-223
- ISSN
- 1523-0899 (ISSN-L)
- OpenAlex
- W1910360816
- Cited by
- 203
- References
- 0
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants: Primary Stability of Dental Implant. https://app.cochat.ai/papers/10.1111/j.1708-8208.2009.00202.x
- The paper
- dos Santos, M. V., Elias, C. N., & Cavalcanti Lima, J. H. (2011). The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants: Primary Stability of Dental Implant. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/j.1708-8208.2009.00202.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.