The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants: Primary Stability of Dental Implant
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Primary implant stability has been used as an indicator for future osseointegration and whether an immediate/early loading protocol should be applied. Implant stability is the key to clinical success. PURPOSE: The aim of this work was to analyze the influence of the design and surface morphology on the primary stability of dental implants. The insertion torque and resonance frequency analysis (RFA) were the parameters used to measure the primary stability of the implants. MATERIALS AND METHODS: Thirty implants, divided in six groups of five samples were placed in cylinder of high molecular weight polyethylene. The groups were different upon two designs (cylindrical and conic) and three implant surfaces finishing (machined, acid etched, and anodized). The insertion torque was quantified by a digital torque driver (Lutron Electronic Enterprise Co., Taipei, Taiwan) and the resonance frequency was measured by Osstell mentor™ (Integration Diagnostics AB, Göteborg, Sweden). The implant surface morphology was characterized by scanning electron microscopy, roughness measurement, and friction coefficient. RESULTS: The machined implants showed smaller insertion torques than treated implant surfaces. There were no differences between the RFA measurements in all tested surfaces. Statistical analyses demonstrated no correlation between the dental implant insertion torque and primary stability measured by the RFA. The implants with treated surfaces showed greater roughness, a higher friction coefficient, and demanded a larger insertion torque than machined implants. The results of the surface roughness and friction coefficients are in accordance with the results of the insertion torque. The difference, across the insertion torque values, between conical and cylindrical implants, can be explained by the different contact surface area among the thread geometry of these implants. CONCLUSION: The maximum implant insertion torque depends on the implant geometry, thread form, and implant surface morphology. The placement of conical implants with treated surfaces required the highest insertion torque. There was no correlation between RFA and insertion torque implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406 · cited 1×
“The dental implant surface treatments have been developed with the objective of improving the osseointegration mechanisms and reducing the loading time of the implants.(8,9) The primary stability of an implant fixture at the time of placement is often estimated by judging the presence of any mobility.”
BackgroundShigley, J. E. (2001) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,157
Ugural, A. C., Chung, Y., & Ugural, E. A. (2020) · CRC Press eBooks · doi:10.1201/9781003099284 · Cited by 464
da Cunha, H. A., Francischone, C. E., Filho, H. N., & de Oliveira, R. C. G. (2004) · PubMed · Cited by 167
Implant design and intraosseous stability of immediately placed implants: a human cadaver study
Akkocaoğlu, M., Uysal, S., Tekdemir, İ., Akça, K., & Çehreli, M. C. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01099.x · Cited by 139 · cited 2×
“The maximum acceptable micromovement described in the literature is between 50 and 150 mm; above these values, the activity of the osteoblasts can be affected.(3,4) However, some studies have shown good results using one-stage surgical protocol, which objective is to reduce the number of surgical interventions, in ord…”
Result
Cited by
Current trends in dental implants
Gaviria, L., Salcido, J. P., Guda, T., & Ong, J. L. (2014) · Journal of the Korean Association of Oral and Maxillofacial Surgeons · doi:10.5125/jkaoms.2014.40.2.50 · Cited by 407
Rao, P. J., Pelletier, M. H., Walsh, W. R., & Mobbs, R. J. (2014) · Orthopaedic Surgery · doi:10.1111/os.12098 · Cited by 285
Rasouli, R., Barhoum, A., & Uludag, H. (2018) · Biomaterials Science · doi:10.1039/c8bm00021b · Cited by 242
Elias, C. N., Rocha, F. A., Nascimento, A. L., & Coelho, P. G. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.10.010 · Cited by 195
“The stability of a screw joint is a function of the friction coefficient (dos Santos et al., 2011; Elias et al., 2006) and the initial tension achieved in the screw when applying the preload tightening torque.”
BackgroundResultInfluentialSelf-citationDvorak, G., Arnhart, C., Heuberer, S., Huber, C. D., Watzek, G., & Gruber, R. (2011) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2011.01772.x · Cited by 192
Improving osseointegration of dental implants
Elias, C. N., & Meirelles, L. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.09.74 · Cited by 188
Self-citationEffects of Titanium Surfaces on the Developmental Profile of Monocytes/Macrophages
Moura, C. C. G., Zanetta-Barbosa, D., Dechichi, P., Carvalho, V. F., & Soares, P. B. F. (2014) · Brazilian Dental Journal · doi:10.1590/0103-6440201302260 · Cited by 10
Metadata
- Authors
- dos Santos, M. V., Elias, C. N., & Cavalcanti Lima, J. H.
- Venue
- Clinical Implant Dentistry and Related Research
- Publisher
- Wiley
- Published
- 2009-09-09
- Volume
- 13
- Issue
- 3
- Pages
- 215-223
- ISSN
- 1523-0899 (ISSN-L)
- OpenAlex
- W1910360816
- Cited by
- 203
- References
- 5
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.