The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Accuracy and Complications Using Computer‐Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature
Abstract
Background: In the last decade several stereolithographic guided surgery systems were introduced to the market. In this context, scientific information regarding accuracy of implant placement and surgical and prosthodontical complications is highly relevant as it provides evidence to implement this surgical technique in a clinical setting. Purpose: To review data on accuracy and surgical and prosthodontical complications using stereolithographical surgical guides for implant rehabilitation. Material and Methods: PubMed database was searched using the following keywords: “three dimensional imaging,”“image based surgery,”“flapless guided surgery,”“customized drill guides,”“computer assisted surgery,”“surgical template,” and “stereolithography.” Only papers in English were selected. Additional references found through reading of selected papers completed the list. Results: In total 31 papers were selected. Ten reported deviations between the preoperative implant planning and the postoperative implant locations. One in vitro study reported a mean apical deviation of 1.0 mm, three ex vivo studies a mean apical deviation ranging between 0.6 and 1.2 mm. In six in vivo studies an apical deviation between 0.95 and 4.5 mm was found. Six papers reported on complications mounting to 42% of the cases when stereolithographic guided surgery was combined with immediate loading. Conclusion: Substantial deviations in three‐dimensional directions are found between virtual planning and actually obtained implant position. This finding and additionally reported postsurgical complications leads to the conclusion that care should be taken whenever applying this technique on a routine basis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Van Assche, N., Van Steenberghe, D., Guerrero, M. E., Hirsch, E., Schutyser, F., Quirynen, M., & Jacobs, R. (2007) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2007.01110.x · Cited by 318
Vrielinck, L., Politis, C., Schepers, S., Pauwels, M., & Naert, I. (2003) · International Journal of Oral and Maxillofacial Surgery · doi:10.1054/ijom.2002.0337 · Cited by 220
Lal, K., White, G. S., Morea, D. N., & Wright, R. F. (2006) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2006.00069.x · Cited by 182
Van Steenberghe, D., Malevez, C., Van Cleynenbreugel, J., Serhal, C. B., Dhoore, E., Schutyser, F., Suetens, P., & Jacobs, R. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140118.x · Cited by 171
An image-guided planning system for endosseous oral implants
Verstreken, K., Van Cleynenbreugel, J., Martens, K., Marchal, G., van Steenberghe, D., & Suetens, P. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736056 · Cited by 171
Fortin, T., Champleboux, G., Bianchi, S. D., Buatois, H., & Coudert, J. (2002) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2002.130612.x · Cited by 146
Lal, K., White, G. S., Morea, D. N., & Wright, R. F. (2006) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2006.00084.x · Cited by 68
Cleynenbreugel, J. V., Schutyser, F., Goffin, J., Brussel, K. V., & Suetens, P. (2002) · Computer Aided Surgery · doi:10.3109/10929080209146015 · Cited by 27
Cited by
Current and emerging applications of 3D printing in medicine
Liaw, C.-Y., & Guvendiren, M. (2017) · Biofabrication · doi:10.1088/1758-5090/aa7279 · Cited by 604
Khorsandi, D., Fahimipour, A., Abasian, P., Saber, S. S., Seyedi, M., Ghanavati, S., Ahmad, A., De Stephanis, A. A., Taghavinezhaddilami, F., Leonova, A., et al. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.12.044 · Cited by 428
Accuracy of computer‐aided implant placement
Van Assche, N., Vercruyssen, M., Coucke, W., Teughels, W., Jacobs, R., & Quirynen, M. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02552.x · Cited by 328
Metadata
- Authors
- D'haese, J., Van De Velde, T., Komiyama, A., Hultin, M., & De Bruyn, H.
- Venue
- Clinical Implant Dentistry and Related Research
- Publisher
- Wiley
- Published
- 2012-06
- Volume
- 14
- Issue
- 3
- Pages
- 321-335
- ISSN
- 1523-0899 (ISSN-L)
- 1708-8208
- OpenAlex
- W2150177901
- Cited by
- 336
- References
- 9
- FWCI
- 14.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy and Complications Using Computer‐Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature. https://app.cochat.ai/papers/10.1111/j.1708-8208.2010.00275.x
- The paper
- D'haese, J., Van De Velde, T., Komiyama, A., Hultin, M., & De Bruyn, H. (2012). Accuracy and Complications Using Computer‐Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/j.1708-8208.2010.00275.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.