Medical device related pressure ulcers in hospitalized patients
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Most pressure ulcers occur over bony prominences such as heels and the sacrum. However, the National Pressure Ulcer Advisory Panel recognises that pressure ulcers can also occur on any tissue under pressure and thereby can develop beneath medical devices. This article reports on results from a secondary analysis of existing data collected by The Nebraska Medical Center on pressure ulcer quality improvement initiatives and outcomes. The purpose of this study was to quantify the extent of the problem and identify risk factors for medical device related (MDR) pressure ulcer development in hospitalised patients. A subset of data collected during eight quarterly pressure ulcer incidence and prevalence studies (N = 2178) was created and analysed. The overall rate of hospital‐acquired pressure ulcers was 5·4% (113 of 2079). The proportion of patients with hospital‐acquired ulcers related to medical devices was 34·5% (39 of 113). Findings indicate that if a patient had a medical device, they were 2·4 times more likely to develop a pressure ulcer of any kind. Numerous risk factors for pressure ulcer development were identified; however, none differentiated between those with MDR and traditional pressure ulcers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grey, J. E., Harding, K. G., & Enoch, S. (2006) · BMJ · doi:10.1136/bmj.332.7539.472 · Cited by 213
Temperature-modulated pressure ulcers: A porcine model
Kokate, J. Y., Leland, K. J., Held, A. M., Hansen, G. L., Kveen, G. L., Johnson, B. A., Wilke, M. S., Sparrow, E. M., & Iaizzo, P. A. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80637-7 · Cited by 171
Clearing the Cervical Spine in Obtunded Patients: The Use of Dynamic Fluoroscopy
Davis, J. W., Parks, S. N., Detlefs, C. L., Williams, G. G., Williams, J. L., & Smith, R. W. (1995) · doi:10.1097/00005373-199509000-00006 · Cited by 147
The effect of protective treatment in reducing pressure ulcers for non-invasive ventilation patients
Weng, M.-H. (2008) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2007.11.005 · Cited by 121
ABC of wound healing: Pressure ulcers
Grey, J. E., & Enoch, S. (2006) · BMJ · doi:10.1136/sbmj.0606226 · Cited by 100
Inspissated secretions: A Life-Threatening Complication of Prolonged Noninvasive Ventilation
Wood, K. E., Flaten, A. L., & Backes, W. J. (2000) · Respiratory Care · doi:10.1177/002013240004500506 · Cited by 54
Nosocomial Pressure Ulcer Rates in Critical Care: Performance Improvement Project
Wolverton, C. L., Hobbs, L. A., Beeson, T., Benjamin, M., Campbell, K. J., Forbes, C., Huff, N. L., Kieninger, M., Luebbehusen, M., Myers, M., et al. (2005) · Journal of Nursing Care Quality · doi:10.1097/00001786-200501000-00010 · Cited by 45
Nasal masks for domiciliary positive pressure ventilation: patient usage and complications.
Jones, D. J. M., Braid, G. M., & Wedzicha, J. A. (1994) · Thorax · doi:10.1136/thx.49.8.811 · Cited by 42
Cited by
Edsberg, L. E., Black, J. M., Goldberg, M., McNichol, L., Moore, L., & Sieggreen, M. (2016) · Journal of Wound, Ostomy & Continence Nursing · doi:10.1097/won.0000000000000281 · Cited by 1,123
Self-citationMedical device-related pressure ulcers: A systematic review and meta-analysis
Jackson, D., Sarki, A. M., Betteridge, R., & Brooke, J. (2019) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2019.02.006 · Cited by 230
“…States in 2008 and 2009 Facility acquired device-related pressure injuries Cross- sectional cohort study NP NP 6589 11.9(785) Other medical devices# Moderate Black 2010 USA To quantify the extent of medical device related pressure injuries and identify the risk factors for pressure ulcer…”
BackgroundInfluentialBiomedical application of optical fibre sensors
Correia, R., James, S., Lee, S.-W., Morgan, S. P., & Korposh, S. (2018) · Journal of Optics · doi:10.1088/2040-8986/aac68d · Cited by 206
Unavoidable Pressure Injury: State of the Science and Consensus Outcomes
Edsberg, L. E., Langemo, D., Baharestani, M. M., Posthauer, M. E., & Goldberg, M. (2014) · Journal of Wound, Ostomy & Continence Nursing · doi:10.1097/won.0000000000000050 · Cited by 203
Kayser, S. A., VanGilder, C. A., Ayello, E. A., & Lachenbruch, C. (2018) · Advances in Skin & Wound Care · doi:10.1097/01.asw.0000532475.11971.aa · Cited by 178
“3% of the patients studied had at least 1 facility-acquired MDR PI.(21) Of the facility-acquired MDR PIs, 5% were Stage 1, 32% were Stage 2, 24% were unstageable, 6% were DTPIs, and 3% were Stage 3.”
BackgroundInfluential
Metadata
- Authors
- Black, J. M., Cuddigan, J. E., Walko, M. A., Didier, L. A., Lander, M. J., & Kelpe, M. R.
- Venue
- International Wound Journal
- Publisher
- Wiley
- Published
- 2010-09-15
- Volume
- 7
- Issue
- 5
- Pages
- 358-365
- ISSN
- 1742-4801 (ISSN-L)
- 1742-481X
- OpenAlex
- W2074033005
- Cited by
- 329
- References
- 8
- FWCI
- 28.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.