CoChat

Mechanical properties of rat cerebral arteries as studied by a sensitive device for recording of mechanical activity in isolated small blood vessels*

HÖGESTÄTT, E. D., ANDERSSON, K. ‐E., EDVINSSON, L. · 1983 · Acta Physiologica Scandinavica
Cited by 400

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

A sensitive device for recording of mechanical activity in isolated small blood vessels with calibres down to 100 μm is described. This equipment was used to examine the mechanical properties of rat cerebral arteries. The ultrastructure of the preparations was investigated by light‐, transmission, and scanning electron‐microscopy. In general the walls of the middle cerebral and basilar arteries consisted of 3 layers of smooth muscle cells, which occupied approximately 80% of the total wall thickness. The present technique preserved the integrity of the vessel wall and caused no observable damage to the smooth muscle or endothelial cells. Neither the basilar nor the middle crebral arteries developed spontaneous phasic contractions under standard conditions. Potassium excess (124 mM) induced a biphasic contractile response characterized by a fast and partly transient increase in tension (phase A), followed by a slowly developing sustained contraction (phase B). The responses to K+were strong, highly reproducible and not influenced by pH changes in the range 6.9‐7.8, making K+‐stimulation suitable for testing of vascular contractility. Length‐tension measurements were performed on relaxed and K+‐activated basilar arteries. The mechanical behaviour of the vessels conformed to a sliding‐filament model of muscular contraction. Using the “Maxwell model” of a muscle, the length at which the contractile element produced maximum active tension was established. The passive wall tension at this length (˜ 1 mN/mm) averaged only about 20% of the total wall tension the arteries were capable of producing when activated by K+. Under isometric conditions the K+‐contracted basilar artery developed a maximum active wall stress of approximately 240 mN/mm 2. In the light of the mechanical data obtained from the length‐tension measurements, the optimum resting wall tension for registration of vascular responses is discussed. It appears that the present in vitro system can be of great value in investigations of the smooth muscle function in small blood vessels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1748-1716.1983.tb07178.x

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

Metadata

Authors
HÖGESTÄTT, E. D., ANDERSSON, K. ‐., & EDVINSSON, L.
Venue
Acta Physiologica Scandinavica
Publisher
Wiley
Published
1983-01
Volume
117
Issue
1
Pages
49-61
ISSN
  • 0001-6772 (ISSN-L)
  • 1365-201X
OpenAlex
W1963861155
Cited by
400
References
22
FWCI
31.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.