Vasomotion – what is currently thought?
Abstract
This minireview discusses vasomotion, which is the oscillation in tone of blood vessels leading to flowmotion. We will briefly discuss the prevalence of vasomotion and its potential physiological and pathophysiological relevance. We will also discuss the models that have been suggested to explain how a coordinated oscillatory activity of the smooth muscle tone can occur and emphasize the role of the endothelium, the handling of intracellular Ca 2+and the role of smooth muscle cell ion conductances. It is concluded that vasomotion is likely to enhance tissue dialysis, although this concept still requires more experimental verification, and that an understanding at the molecular level for the pathways leading to vasomotion is beginning to emerge.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Most prior studies have concluded that vasomotion reflects intrinsic activity of vascular smooth muscle cells.
“Most prior studies have concluded that vasomotion reflects intrinsic activity of vascular smooth muscle cells78,79.”
From Norepinephrine-mediated slow vasomotion drives glymphatic clearance during sleep (2025) · cites this paper as [79]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 217
- 10.1038/sj.bjp.0706084 · DOI
- 10.1042/cs0690477 · DOI
- 10.1161/01.RES.61.2.181 · DOI
- 10.1254/jjp.68.331 · DOI
- 10.1016/j.brainres.2009.09.119 · DOI
- 10.1006/bbrc.1996.1484 · DOI
- 10.1159/000054090 · DOI
- 10.1111/j.1440-1681.2005.04251.x · DOI
- 10.1042/cs0880191 · DOI
- 10.1016/S0008-6363(97)00017-5 · DOI
- 10.1016/j.mvr.2008.07.006 · DOI
- Berridge M.J., 1979, A comparative survey of the function, mechanism and control of cellular oscillators, J Exp Biol, 81, 217, 10.1242/jeb.81.1.217 · DOI
- 10.1152/ajpheart.1991.260.2.H362 · DOI
- 10.1006/mvre.1995.1050 · DOI
- Blatter L.A., 1992, Agonist‐induced [Ca2+]i waves and Ca2+‐induced Ca2+ release in mammalian vascular smooth muscle cells, Am J Physiol, 263, H576
- 10.1016/j.medengphy.2010.02.004 · DOI
- 10.1007/s00424-008-0532-3 · DOI
- 10.1006/mvre.1993.1008 · DOI
- 10.1152/ajpcell.1999.277.1.C139 · DOI
- Bollinger A., 1991, Evaluation of flux motion in man by the laser‐Doppler technique, Blood Vessels, 28, 21
- 10.1159/000422452 · DOI
- Borgström P., 1992, Slow‐wave flowmotion in rabbit skeletal muscle after acute fixed‐volume hemorrhage, Circ Shock, 36, 57
- 10.1159/000084405 · DOI
- Bouskela E., 1988, Effects of metformin on the wing microcirculation of normal and diabetic bats, Diabete Metab, 14, 560
- 10.1159/000159055 · DOI
- Bouskela E., 1992, Spontaneous vasomotion in hamster cheek pouch arterioles in varying experimental conditions, Am J Physiol, 262, H478
- 10.1177/000331979704800605 · DOI
- Bova S., 1990, Influence of Na+ gradient on Ca2+ transients and contraction in vascular smooth muscle, Am J Physiol, 259, H409
- 10.1016/0026-2862(92)90103-V · DOI
- 10.1111/j.1440-1681.1996.tb01172.x · DOI
- 10.1046/j.1365-201X.1998.00439.x · DOI
- Broegger T. Jacobsen J.C. Dam V.S. Boedtkjer D.M.B. Kold‐Petersen H. Pedersen F.S. Aalkjaer C.&Matchkov V.V.2011.Downregulation of bestrophin‐3 reduces the rhytmic but not the tonic contraction in rat mesenteric small arteries. [Epub ahead of print]. · DOI
- Burrows M.E., 1981, Diameter, wall tension, and flow in mesenteric arterioles during autoregulation, Am J Physiol, 241, H829
- 10.1126/science.1163518 · DOI
- 10.1111/j.1469-7793.1997.099bi.x · DOI
- 10.1111/j.1582-4934.2009.00890.x · DOI
- 10.1159/000057761 · DOI
- 10.1113/jphysiol.2009.174557 · DOI
- Colantuoni A., 1984, Effects of anesthesia on the spontaneous activity of the microvasculature, Int J Microcirc Clin Exp, 3, 13
- Colantuoni A., 1984, Quantitation of rhythmic diameter changes in arterial microcirculation, Am J Physiol, 246, H508
- 10.1016/0026-2862(84)90014-1 · DOI
- 10.1016/0026-2862(85)90045-7 · DOI
- 10.1007/BF00583602 · DOI
- 10.1007/978-1-4684-8181-5_62 · DOI
- Collin O., 2000, Testicular vasomotion in different mammals, Asian J Androl, 2, 297
- 10.1111/j.1365-2605.1990.tb00977.x · DOI
- 10.1111/j.1365-2605.1992.tb01353.x · DOI
- 10.1161/01.RES.65.3.708 · DOI
- 10.1006/mvre.1993.1028 · DOI
- 10.1038/sj.bjp.0703986 · DOI
- 10.1161/01.RES.87.6.474 · DOI
- Fagrell B., 1977, A microscope‐television system for studying flow velocity in human skin capillaries, Am J Physiol, 233, H318
- 10.1161/01.HYP.0000242483.03361.da · DOI
- 10.1113/jphysiol.1989.sp017835 · DOI
- 10.1161/01.RES.78.1.148 · DOI
- 10.1006/jtbi.2000.2254 · DOI
- 10.1046/j.1365-2818.1999.00599.x · DOI
- 10.1016/j.tips.2006.11.004 · DOI
- 10.1111/j.1469-7793.2001.00395.x · DOI
- 10.1016/S0008-6363(95)00147-6 · DOI
- Griffith T.M., 1993, Mechanisms underlying chaotic vasomotion in isolated resistance arteries: roles of calcium and EDRF, Biorheology, 30, 333, 10.3233/BIR-1993-305-605 · DOI
- Griffith T.M., 1993, Modulation of chaotic pressure oscillations in isolated resistance arteries by EDRF, Eur Heart J, 14, 60
- Griffith T.M., 1995, Complexity of chaotic vasomotion is insensitive to flow and pressure but can be regulated by external control, Am J Physiol, 269, H656
- Gustafsson H., 1993, Vasomotion and underlying mechanisms in small arteries. An in vitro study of rat blood vessels, Acta Physiol Scand, 149, 1
- 10.1111/j.1748-1716.1993.tb09623.x · DOI
- 10.1111/j.1748-1716.1994.tb09673.x · DOI
- 10.1016/0026-2862(91)90090-X · DOI
- 10.1111/j.1748-1716.1993.tb09545.x · DOI
- 10.1111/j.1748-1716.1994.tb09794.x · DOI
- Gustafsson F., 2003, Expression of connexin 37, 40 and 43 in rat mesenteric arterioles and resistance arteries, Histochem Cell Biol, 119, 139, 10.1007/s00418-002-0493-0 · DOI
- 10.1113/jphysiol.2002.027904 · DOI
- 10.1113/jphysiol.2005.086405 · DOI
- 10.1113/jphysiol.2001.013698 · DOI
- 10.1152/ajpheart.00484.2006 · DOI
- 10.1016/j.jtbi.2010.03.002 · DOI
- 10.1152/physiol.00021.2005 · DOI
- van Helden D.F., 2006, Rhythmicity in the microcirculation, Clin Hemorheol Microcirc, 34, 59
- 10.1016/j.pbiomolbio.2007.03.010 · DOI
- 10.1111/j.1600-0420.2006.00633.x · DOI
- 10.1111/j.1469-7793.1999.00507.x · DOI
- 10.1046/j.1440-1681.2002.03699.x · DOI
- 10.1152/ajpheart.1999.277.5.H1732 · DOI
- Hoffmann U., 1994, Low frequency oscillations of skin blood flux in peripheral arterial occlusive disease, Vasa, 23, 120
- 10.1016/j.cardiores.2003.04.001 · DOI
- Hundley W.G., 1988, Vasomotion in cerebral microcirculation of awake rabbits, Am J Physiol, 254, H67
- Iida N., 1990, Effects of vasomotion and venous pressure elevation on capillary‐tissue fluid exchange across hetero‐porous membrane, Biorheology, 27, 205, 10.3233/BIR-1990-27206 · DOI
- 10.1002/j.1460-2075.1994.tb06831.x · DOI
- 10.1161/01.RES.0000173461.36221.2e · DOI
- Jackson W.F., 1988, Oscillations in active tension in hamster aortas: role of the endothelium, Blood Vessels, 25, 144
- 10.1080/10739680590896072 · DOI
- Jackson W.F., 1991, Rhythmic smooth muscle activity in hamster aortas is mediated by continuous release of NO from the endothelium, Am J Physiol, 260, H248
- 10.1152/ajpheart.00727.2006 · DOI
- 10.1152/ajpheart.00726.2006 · DOI
- 10.1098/rsta.2008.0105 · DOI
- 10.1152/ajpcell.2000.279.5.C1528 · DOI
- Jamsek J., 2007, The cardio‐respiratory couplings observed in the LDF signal using wavelet biospectrum, Conf Proc IEEE Eng Med Biol Soc, 2007, 4072
- Jensen B.L., 1997, Chloride is essential for contraction of afferent arterioles after agonists and potassium, Am J Physiol, 272, F389
- 10.1098/rstl.1852.0011 · DOI
- 10.1080/714040444 · DOI
- 10.1016/0165-1838(91)90107-E · DOI
- Kastrup J., 1989, Vasomotion in human skin before and after local heating recorded with laser‐Doppler flowmetry. A method for induction of vasomotion, Int J Microcirc Clin Exp, 8, 205
- Kaufman A.G., 1985, Automated diameter measurement of vasomotion by cross‐correlation, Int J Microcirc Clin Exp, 4, 45
- 10.1186/1742-4682-7-29 · DOI
- 10.1529/biophysj.103.037853 · DOI
- 10.1529/biophysj.108.131136 · DOI
- 10.1016/S0026-2862(03)00006-2 · DOI
- 10.1016/j.mvr.2006.05.006 · DOI
- 10.1006/mvre.1998.2108 · DOI
- 10.1006/mvre.1998.2139 · DOI
- 10.1161/hs1101.098526 · DOI
- 10.1152/ajpheart.1998.275.1.H151 · DOI
- 10.1152/ajpheart.00526.2002 · DOI
- 10.1152/physiol.00040.2005 · DOI
- 10.1111/j.1469-7793.2001.t01-1-00641.x · DOI
- 10.1016/0026-2862(90)90065-Y · DOI
- 10.1007/s00125-002-1004-5 · DOI
- 10.1095/biolreprod63.5.1383 · DOI
- Mahler F., 1979, Blood pressure fluctuations in human nailfold capillaries, Am J Physiol, 236, H888
- Marchenko S.M., 1994, Smooth muscle cells affect endothelial membrane potential in rat aorta, Am J Physiol, 267, H804
- 10.2170/jjphysiol.32.453 · DOI
- Matchkov V.V., 2010, Mechanisms of cellular synchronization in the vascular wall. Mechanisms of vasomotion, Dan Med Bull, 57, B4191
- 10.1085/jgp.200308972 · DOI
- 10.1038/sj.bjp.0705870 · DOI
- 10.1007/s00424-005-1472-9 · DOI
- 10.1152/ajpheart.00681.2005 · DOI
- 10.1161/01.RES.0000262659.09293.56 · DOI
- 10.1161/CIRCRESAHA.108.178517 · DOI
- 10.1152/ajpheart.01084.2003 · DOI
- 10.1152/ajpheart.2001.280.5.H2399 · DOI
- 10.1074/jbc.M311797200 · DOI
- 10.1016/0026-2862(88)90062-3 · DOI
- 10.1016/S0026-2862(02)00015-8 · DOI
- 10.1055/s-2003-39238 · DOI
- 10.1111/j.1464-5491.2009.02792.x · DOI
- 10.1111/j.1469-7793.1999.0815p.x · DOI
- 10.1111/j.1748-1716.1992.tb09444.x · DOI
- 10.1113/jphysiol.1982.sp014418 · DOI
- 10.1113/jphysiol.2009.169011 · DOI
- 10.1124/mi.3.2.79 · DOI
- Ohta I., 1988, Oxygen transport to tissue during recurrent blood flow supply by grouped capillaries in skeletal muscle with or withoutfacilitateddiffusion, AdvExpMedBiol, 222, 105
- 10.1016/S0024-3205(02)02014-3 · DOI
- 10.1097/00000542-200305000-00019 · DOI
- 10.1111/j.1748-1716.1993.tb09587.x · DOI
- 10.1111/j.1748-1716.1992.tb09367.x · DOI
- Osol G., 1988, Spontaneous vasomotion in pressurized cerebral arteries from genetically hypertensive rats, Am J Physiol, 254, H28
- Oude Vrielink H.H., 1990, Analysis of vasomotion waveform changes during pressure reduction and adenosine application, Am J Physiol, 258, H29
- 10.1529/biophysj.107.106278 · DOI
- Pekanmaki K., 1991, Laser‐Doppler vasomotion among patients with post‐thrombotic venous insufficiency: effect of intermittent pneumatic compression, Vasa, 20, 394
- 10.1111/j.1365-201X.1998.tb10701.x · DOI
- 10.1152/ajpheart.1998.274.2.H655 · DOI
- 10.1161/hh0801.089603 · DOI
- 10.1113/jphysiol.2004.070045 · DOI
- 10.1113/jphysiol.2003.057646 · DOI
- 10.1016/j.mbs.2007.02.010 · DOI
- 10.5271/sjweh.2152 · DOI
- 10.1159/000086002 · DOI
- 10.1016/j.ceca.2007.01.007 · DOI
- 10.3109/00016489409126052 · DOI
- 10.1016/S1056-8727(98)00018-X · DOI
- 10.1161/01.HYP.31.1.335 · DOI
- 10.1016/0165-1838(90)90117-2 · DOI
- 10.1016/j.mvr.2006.04.001 · DOI
- 10.1016/j.biopha.2006.07.012 · DOI
- Rossi M., 2009, Study of skin vasomotion during phollicular and luteal phase in young healthy women, Clin Hemorheol Microcirc, 42, 107, 10.3233/CH-2009-1189 · DOI
- 10.1007/s11695-010-0286-9 · DOI
- 10.1152/ajpheart.2000.279.2.H550 · DOI
- 10.1161/01.RES.86.4.e72 · DOI
- 10.1111/j.1440-1681.2004.04071.x · DOI
- Ryan A.J., 1995, Responses of rat mesenteric arteries to norepinephrine during exposure to heat stress and acidosis, J Appl Physiol, 78, 38, 10.1152/jappl.1995.78.1.38 · DOI
- 10.1152/ajpheart.00280.2006 · DOI
- Salter K.J., 1998, Differential electrophysiological actions of endothelin‐1 on Cl− and K+ currents in myocytes isolated from aorta, basilar and pulmonary artery, J Pharmacol Exp Ther, 284, 1122, 10.1016/S0022-3565(24)37326-4 · DOI
- 10.1113/expphysiol.1995.sp003889 · DOI
- 10.1016/j.cardiores.2003.09.017 · DOI
- Scheffler A., 1992, Spontaneous oscillations of laser‐Doppler skin blood flux in peripheral arterial occlusive disease, Int J Microcirc Clin Exp, 11, 249
- Schmidt J.A., 1996, Periodic Hemodynamics in Health and Disease
- 10.1152/jappl.1992.73.3.1077 · DOI
- 10.1067/mva.1993.42773 · DOI
- 10.1159/000178946 · DOI
- Schmidt V.J., 2008, Gap junctions synchronize vascular tone within the microcirculation, Pharmacol Rep, 60, 68
- 10.1016/S0024-3205(02)02110-0 · DOI
- 10.1016/j.cell.2008.09.003 · DOI
- 10.1152/ajpheart.2001.280.3.H1088 · DOI
- 10.1097/00005344-200404000-00009 · DOI
- 10.1152/ajpheart.1992.263.1.H1 · DOI
- 10.1152/ajpheart.1989.256.3.H838 · DOI
- 10.1016/S0143-4160(02)00036-2 · DOI
- 10.1111/j.1365-2605.1995.tb00397.x · DOI
- 10.1159/000409285 · DOI
- 10.1007/978-3-642-76877-4_3 · DOI
- 10.1016/0026-2862(87)90008-2 · DOI
- Slaaf D.W., 1988, Effective diameter as a determinant of local vascular resistance in presence of vasomotion, Am J Physiol, 255, H1240
- 10.1054/ceca.2001.0199 · DOI
- 10.2337/diacare.19.7.715 · DOI
- 10.1109/EMB.2007.907088 · DOI
- 10.1152/ajpheart.01192.2008 · DOI
- 10.1139/y05-016 · DOI
- 10.1161/01.HYP.25.4.474 · DOI
- Tsai A.G., 1993, Evidence of flowmotion induced changes in local tissue oxygenation, Int J Microcirc Clin Exp, 12, 75
- 10.1097/00004872-199510000-00007 · DOI
- 10.1113/jphysiol.1991.sp018555 · DOI
200 of 217 shown
Cited by
Sorted by citations
Resting-state fMRI confounds and cleanup
Murphy, K., Birn, R. M., & Bandettini, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.001 · Cited by 666
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Renal Autoregulation in Health and Disease
Carlström, M., Wilcox, C. S., & Arendshorst, W. J. (2015) · Physiological Reviews · doi:10.1152/physrev.00042.2012 · Cited by 485
Norepinephrine-mediated slow vasomotion drives glymphatic clearance during sleep
Hauglund, N. L., Andersen, M., Tokarska, K., Radovanovic, T., Kjaerby, C., Sørensen, F. L., Bojarowska, Z., Untiet, V., Ballestero, S. B., Kolmos, M. G., et al. (2025) · Cell · doi:10.1016/j.cell.2024.11.027 · Cited by 349
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Noble, D. J., & Hochman, S. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01176 · Cited by 160
Metadata
- Authors
- Aalkjær, C., Boedtkjer, D., & Matchkov, V.
- Affiliations
- Aarhus University (DK)
- Corresponding author
- Aalkjær, C.
- Venue
- Acta Physiologica
- Publisher
- Wiley
- Published
- 2011-05-27
- Volume
- 202
- Issue
- 3
- Pages
- 253-269
- ISSN
- 1748-1708 (ISSN-L)
- 1748-1716
- OpenAlex
- W1505333444
- Cited by
- 252
- References
- 0
- Citations by year
- 2026: 12 · 2025: 18 · 2024: 15 · 2023: 19 · 2022: 19 · 2021: 18 · 2020: 21 · 2019: 25 · 2018: 18 · 2017: 18 · 2016: 14 · 2015: 14 · 2014: 19 · 2013: 8 · 2012: 9
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Acta Physiologica (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Nitric Oxide and Endothelin Effects
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Keywords
- vasomotion, vascular smooth muscle, endothelium, intracellular calcium, ionic conductance
- MeSH terms
- Animals, Calcium, Cell Communication, Chlorides, Endothelium, Vascular, Humans, Membrane Potentials, Mesenteric Arteries, Models, Biological, Muscle, Smooth, Vascular, Vasomotor System, Gap Junctions, Calcium Signaling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review