Autoantibody Detection Using Indirect Immunofluorescence on HEp‐2 Cells
The DOI matches its Crossref record.
Abstract
The detection of autoantibodies is an important element in the diagnosis and monitoring of disease progression in patients with autoimmune diseases. In laboratory diagnostic tests for connective tissue and autoimmune liver diseases, indirect immunofluorescence on HEp‐2 cells plays a central role in a multistage diagnostic process. Despite the high quality of diagnostics, findings at different laboratories can differ considerably due to a lack of standardization, as well as subjective factors. The present paper formulates recommendations for the standardized processing and interpretation of the HEp‐2 cell test for the detection of non‐organ‐specific (especially antinuclear) antibodies. It provides requirements regarding the diagnostic tests used, instructions for laboratory procedure and evaluation, and recommendations for interpretation. For an optimal laboratory diagnostic process, it is useful to have an informative, tentative clinical diagnosis and an experienced laboratory diagnostician. In addition, the following key elements are recommended: initial screening using indirect immunofluorescence on carefully chosen HEp‐2 cells beginning with a serum dilution of 1:80 and evaluation under a microscope with powerful illumination; results from a titer of 1:160 upwards being considered positive; internal laboratory quality control; and standardized interpretation. The aim is to improve diagnostic tests and care of patients with autoimmune diseases as a central concern of the European Autoimmunity Standardization Initiative (EASI).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chan, E. K. L., Damoiseaux, J., Carballo, O. G., Conrad, K., de Melo Cruvinel, W., Francescantonio, P. L. C., Fritzler, M. J., Garcia-De La Torre, I., Herold, M., Mimori, T., et al. (2015) · Frontiers in Immunology · doi:10.3389/fimmu.2015.00412 · Cited by 383
Self-citationAutoantibody diagnostics in clinical practice
Conrad, K., Roggenbuck, D., Reinhold, D., & Sack, U. (2012) · Autoimmunity Reviews · doi:10.1016/j.autrev.2011.05.014 · Cited by 64
Self-citationDetection of anti-dsDNA antibodies by computer-aided automated immunofluorescence analysis
Lakos, G., Gonzalez, M., Flaherty, D., Bentow, C., Ibarra, C., Stimson, D., Nacario, L., Hiemann, R., & Dervieux, T. (2016) · Journal of Immunological Methods · doi:10.1016/j.jim.2016.02.019 · Cited by 14
Trujillo Aguilera, A., Bernardo Serrano, R., Navas, A., Alcaide Molina, J., Alvarez Romero, P., & Jurado Roger, A. (2023) · Lupus Science & Medicine · doi:10.1136/lupus-2023-000984 · Cited by 6
Metadata
- Authors
- Sack, U., Conrad, K., Csernok, E., Frank, I., Hiepe, F., Krieger, T., Kromminga, A., Von Landenberg, P., Messer, G., Witte, T., Mierau, R., & Initiative), F. T. G. E. (. A. S.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 2009-09
- Volume
- 1173
- Issue
- 1
- Pages
- 166-173
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W1995670896
- Cited by
- 98
- References
- 0
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Autoantibody Detection Using Indirect Immunofluorescence on HEp‐2 Cells. https://app.cochat.ai/papers/10.1111/j.1749-6632.2009.04735.x
- The paper
- Sack, U., Conrad, K., Csernok, E., Frank, I., Hiepe, F., Krieger, T., Kromminga, A., Von Landenberg, P., Messer, G., Witte, T., Mierau, R., & Initiative), F. T. G. E. (. A. S. (2009). Autoantibody Detection Using Indirect Immunofluorescence on HEp‐2 Cells. Annals of the New York Academy of Sciences. https://doi.org/10.1111/j.1749-6632.2009.04735.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.