Detection of Melamine in Gluten, Chicken Feed, and Processed Foods Using Surface Enhanced Raman Spectroscopy and HPLC
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Melamine, a nitrogen‐rich chemical, was implicated in pet and human food recalls in 2007, which caused enormous economic losses to the food industry. In this study, melamine concentration in wheat gluten, chicken feed, and processed foods (that is, cake and noodle) was measured by surface enhanced Raman spectroscopy (SERS) in combination with SERS‐active substrates. SERS was able to rapidly detect 0.1% melamine in wheat gluten, 0.05% in chicken feed, 0.05% in cakes, and 0.07% in noodle, respectively. A partial least squares (PLS) model was established for the quantification of melamine in foods by SERS: R = 0.90, RMSEP = 0.33. In addition, SERS results were verified by HPLC analysis based on a simplified FDA method. Compared with HPLC, the SERS method is much faster and simpler, requires minimum sample preparation, but still yields satisfactory qualitative and quantitative results. These results demonstrate that it is an applicable approach to use SERS to screen foods, eliminate presumptive negative samples of melamine contamination from the sample population, and then verify presumptive positive samples using HPLC protocols. Combining these 2 methods could provide a more rapid and cost‐effective way for monitoring melamine contamination in increasingly large numbers of imported foods and feed products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasensitive Chemical Analysis by Raman Spectroscopy
Kneipp, K., Kneipp, H., Itzkan, I., Dasari, R. R., & Feld, M. S. (1999) · Chemical Reviews · doi:10.1021/cr980133r · Cited by 2,181
Surface-Enhanced Raman Spectroscopy
Haynes, C. L., McFarland, A. D., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac053456d · Cited by 1,144
Surface-enhanced Raman scattering and biophysics
Kneipp, K., Kneipp, H., Itzkan, I., Dasari, R. R., & Feld, M. S. (2002) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/14/18/202 · Cited by 998
Surface-Enhanced Raman Spectroscopy in Single Living Cells Using Gold Nanoparticles
Kneipp, K., Haka, A. S., Kneipp, H., Badizadegan, K., Yoshizawa, N., Boone, C., Shafer-Peltier, K. E., Motz, J. T., Dasari, R. R., & Feld, M. S. (2002) · Applied Spectroscopy · doi:10.1366/0003702021954557 · Cited by 576
The applications of Raman spectroscopy in food science
Li-Chan, E. C. Y. (1996) · Trends in Food Science & Technology · doi:10.1016/s0924-2244(96)10037-6 · Cited by 510
Infrared Spectroscopy in Microbiology
Naumann, D. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0117 · Cited by 415
He, L., Liu, Y., Lin, M., Awika, J. M., Ledoux, D. R., Li, H., & Mustapha, A. (2008) · Sensing and Instrumentation for Food Quality and Safety · doi:10.1007/s11694-008-9038-0 · Cited by 155
Self-citationRaman-based detection of bacteria using silver nanoparticles conjugated with antibodies
Naja, G. M., Bouvrette, P., Hrapovic, S., & Luong, J. H. T. (2007) · The Analyst · doi:10.1039/b701160a · Cited by 140
Martens, H. A., & Geladi, P. L. M. (2014) · Wiley eBooks · doi:10.1002/9781118445112.stat02454 · Cited by 136
Release of formaldehyde and melamine from tableware made of melamine — formaldehyde resin
Sugita, T., Ishiwata, H., & Yoshihira, K. (1990) · Food Additives and Contaminants · doi:10.1080/02652039009373815 · Cited by 52
Cited by
Duncan, T. V. (2011) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2011.07.017 · Cited by 2,029
McNay, G., Eustace, D., Smith, W. E., Faulds, K., & Graham, D. (2011) · Applied Spectroscopy · doi:10.1366/11-06365 · Cited by 655
Evolving trends in SERS-based techniques for food quality and safety: A review
Jiang, L., Hassan, M. M., Ali, S., Li, H., Sheng, R., & Chen, Q. (2021) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2021.04.006 · Cited by 470
Self-citationFingerprinting food: current technologies for the detection of food adulteration and contamination
Ellis, D. I., Brewster, V. L., Dunn, W. B., Allwood, J. W., Golovanov, A. P., & Goodacre, R. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35138b · Cited by 440
Common milk adulteration and their detection techniques
Azad, T., & Ahmed, S. (2016) · International Journal of Food Contamination · doi:10.1186/s40550-016-0045-3 · Cited by 339
Surface‐Enhanced Raman Spectroscopy for the Chemical Analysis of Food
Zheng, J., & He, L. (2014) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12062 · Cited by 330
Self-citationSurface-Enhanced Raman Spectroscopy and Homeland Security: A Perfect Match?
Golightly, R. S., Doering, W. E., & Natan, M. J. (2009) · ACS Nano · doi:10.1021/nn9013593 · Cited by 244
“pet food contaminant that has garnered recent worldwide attention.(47) In this”
BackgroundSimple SERS substrates: powerful, portable, and full of potential
Betz, J. F., Yu, W. W., Cheng, Y., White, I. M., & Rubloff, G. W. (2014) · Phys. Chem. Chem. Phys. · doi:10.1039/c3cp53560f · Cited by 240
Application of Mid-infrared and Raman Spectroscopy to the Study of Bacteria
Lu, X., Al-Qadiri, H. M., Lin, M., & Rasco, B. A. (2011) · Food and Bioprocess Technology · doi:10.1007/s11947-011-0516-8 · Cited by 236
Self-citationPerumal, J., Wang, Y., Attia, A. B. E., Dinish, U. S., & Olivo, M. (2021) · Nanoscale · doi:10.1039/d0nr06832b · Cited by 235
Fundamentals and applications of SERS-based bioanalytical sensing
Kahraman, M., Mullen, E. R., Korkmaz, A., & Wachsmann-Hogiu, S. (2017) · Nanophotonics · doi:10.1515/nanoph-2016-0174 · Cited by 204
“Adulterants can be detected using SERS [180] in wheat gluten, chicken feed, cakes, and noodles [181].”
BackgroundNeng, J., Zhang, Q., & Sun, P. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112480 · Cited by 203
Chemical analysis in vivo and in vitro by Raman spectroscopy—from single cells to humans
Wachsmann-Hogiu, S., Weeks, T., & Huser, T. (2009) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2009.02.006 · Cited by 203
“It was also shown that very low concentrations of melamine in food could be detected using commercially available SERS-active substrates [19].”
BackgroundZnO/Au Composite Nanoarrays As Substrates for Surface-Enhanced Raman Scattering Detection
Chen, L., Luo, L., Chen, Z., Zhang, M., Zapien, J. A., Lee, C. S., & Lee, S. T. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp908423v · Cited by 201
Analytical methods and recent developments in the detection of melamine
Sun, F., Ma, W., Xu, L., Zhu, Y., Liu, L., Peng, C., Wang, L., Kuang, H., & Xu, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.06.011 · Cited by 199
Bioanalytical applications of SERS (surface-enhanced Raman spectroscopy)
Hudson, S. D., & Chumanov, G. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2756-2 · Cited by 170
“... silicon wafers were patterned with 150 nm-deep wells and overcoated with thin layers of Ag and Au to create 15±10 nm gaps where the electromagnetic field was expected to be high and could be used to measure SERS signals from both adsorbed DNA and the Raman-active dye Rhodamine B. Commercially available Klarite™ SE…”
MethodAlam, M. M., Asiri, A. M., Uddin, M. T., Inamuddin, I., Islam, M. A., Awual, M. R., & Rahman, M. M. (2019) · New Journal of Chemistry · doi:10.1039/c8nj06361c · Cited by 169
Zhang, Y., Huang, Y., Zhai, F., Du, R., Liu, Y., & Lai, K. (2012) · Food Chemistry · doi:10.1016/j.foodchem.2012.04.082 · Cited by 161
“Various studies indicated the great potential of SERS as a rapid and sensitive analytical method in a wide range of areas, yet there is very limited study on using SERS to detect chemical hazards in food products, particularly in aquatic food products (Canada-Canada, Munoz de la Pena, & Espinosa-Mansilla, 2009; He, Ki…”
BackgroundMethodHe, L., Lin, M., Li, H., & Kim, N. (2010) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2505 · Cited by 161
Self-citationFan, Y., Lai, K., Rasco, B. A., & Huang, Y. (2015) · LWT - Food Science and Technology · doi:10.1016/j.lwt.2014.08.011 · Cited by 116
Metadata
- Authors
- Lin, M., He, L., Awika, J., Yang, L., Ledoux, D. R., Li, H., & Mustapha, A.
- Venue
- Journal of Food Science
- Publisher
- Wiley
- Published
- 2008-10
- Volume
- 73
- Issue
- 8
- Pages
- T129-34
- ISSN
- 0022-1147 (ISSN-L)
- 1750-3841
- OpenAlex
- W2052172233
- Cited by
- 289
- References
- 11
- FWCI
- 32.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.