ICSH recommendations for identification, diagnostic value, and quantitation of schistocytes
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Summary: Schistocytes are fragments of red blood cells (RBCs) produced by extrinsic mechanical damage within the circulation. The detection of schistocytes is an important morphological clue to the diagnosis of thrombotic microangiopathic anemia (TMA). Reporting criteria between different laboratories, however, are not uniform, owing to variability of shape and nature of fragments, as well as subjectivity and heterogeneity in their morphological assessment. Lack of standardization may lead to inconsistency or misdiagnosis, thereby affecting treatment and clinical outcome. The Schistocyte Working Group of the International Council for Standardization in Haematology (ICSH) has prepared specific recommendations to standardize schistocyte identification, enumeration, and reporting. They deal with the type of smear, method of counting, morphological description based on positive criteria (helmet cells, small, irregular triangular, or crescent‐shaped cells, pointed projections, and lack of central pallor). A schistocyte count has a definite clinical value for the diagnosis of TMA in the absence of additional severe red cell shape abnormalities, with a confident threshold value of 1%. Automated counting of RBC fragments is also recommended by the ICSH Working Group as a useful complement to the microscope, according to the high predictive value of negative results, but worthy of further research and with limits in quantitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Methods: The History, Physical, and Laboratory Examinations
Kruse, J. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03450210108045 · Cited by 2,029
Moake, J. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmra020528 · Cited by 1,221
Wintrobe’s Clinical Hematology
Mehta, P. (2009) · JAMA · doi:10.1001/jama.2009.1818 · Cited by 1,160
Thrombotic Thrombocytopenic Purpura
(2006) · New England Journal of Medicine · doi:10.1056/nejmc061483 · Cited by 573
Ruutu, T., Barosi, G., Benjamin, R. J., Clark, R. E., George, J. N., Gratwohl, A., Holler, E., Iacobelli, M., Kentouche, K., Lammle, B., et al. (2007) · Haematologica · doi:10.3324/haematol.10699 · Cited by 395 · cited 3×
“A new developing area for schistocyte counting is monitoring of patients after transplantation of hematopoietic stem cells, in which TMA is a frequent and severe complication (Zomas et al., 1998; Martinez et al., 2005; Ruutu et al., 2007; Lesesve et al., 2011).”
BackgroundBARNES, P. W., MCFADDEN, S. L., MACHIN, S. J., & SIMSON, E. (2005) · Laboratory Hematology · doi:10.1532/lh96.05019 · Cited by 294 · cited 1×
“The blood smear should be spread, air-dried, fixed, and stained according to standard procedures with panoptical stains, as reported by ICSH (1984) and confirmed by international studies (Barnes et al., 2005).”
MethodSelf-citationBlood Cells: A Practical Guide
(2006) · Wiley eBooks · doi:10.1002/9780470987551 · Cited by 271
The Production of Schistocytes by Fibrin Strands (A Scanning Electron Microscope Study)
BULL, B. S., & KUHN, I. N. (1970) · Blood · doi:10.1182/blood.v35.1.104.104 · Cited by 98 · cited 1×
“The origin of RBC fragments may be as heterogeneous as their shapes: (i) mechanical damage by filaments of fibrin in the microvessels (Bull & Kuhn, 1970; Bessis, 1976), as in TMA, but also increased turbulence, shear stress, and RBC adhesion to abnormal endothelium, e.g. within the heart or great…”
BackgroundTheml, H., Diem, H., & Haferlach, T. (2004) · Thieme eBooks · doi:10.1055/b-005-148949 · Cited by 78
Cellules du sang : normal et pathologique
BESSIS, M. C. (1972) · Masson eBooks · Cited by 75
Metadata
- Authors
- ZINI, G., d’ONOFRIO, G., BRIGGS, C., ERBER, W., JOU, J. M., LEE, S. H., McFADDEN, S., VIVES‐CORRONS, J. L., YUTAKA, N., & LESESVE, J. F.
- Venue
- International Journal of Laboratory Hematology
- Publisher
- Wiley
- Published
- 2011-11-15
- Volume
- 34
- Issue
- 2
- Pages
- 107-116
- ISSN
- 1751-5521 (ISSN-L)
- 1751-553X
- OpenAlex
- W2104756521
- Cited by
- 194
- References
- 15
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ICSH recommendations for identification, diagnostic value, and quantitation of schistocytes. https://app.cochat.ai/papers/10.1111/j.1751-553x.2011.01380.x
- The paper
- ZINI, G., d’ONOFRIO, G., BRIGGS, C., ERBER, W., JOU, J. M., LEE, S. H., McFADDEN, S., VIVES‐CORRONS, J. L., YUTAKA, N., & LESESVE, J. F. (2012). ICSH recommendations for identification, diagnostic value, and quantitation of schistocytes. International Journal of Laboratory Hematology. https://doi.org/10.1111/j.1751-553x.2011.01380.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.