ASH Position Paper: Home and Ambulatory Blood Pressure Monitoring When and How to Use Self (Home) and Ambulatory Blood Pressure Monitoring
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The American Society of Hypertension will publish a series of Position Papers in their official journals throughout the coming months. The following Position Paper originally appeared: JASH. 2008;2(3)119–124 and is reprinted here with permission of the publisher. The accurate measurement of blood pressure (BP) remains the most important technique for evaluating hypertension and its consequences, and there is increasing evidence that the traditional office BP measurement procedure may yield inadequate or misleading estimates of a patient's true BP status. The limitations of office BP measurement arise from at least 4 sources: (1) the inherent variability of BP coupled with the small number of readings that are typically taken in the doctor's office; (2) poor technique (eg, terminal digit preference, rapid cuff deflation, improper cuff and bladder size); (3) the white-coat effect (the increase in BP that occurs in the medical care environment), and (4) the masked effect (a decrease in BP that occurs in the medical care environment that may lead to undertreatment; in the case of masked hypertension, the out-of-office BP is hypertensive, while the resting, in-office BP is normotensive or substantially lower than the out-of-office BP). Nearly 70 years ago, there were observations made that office BP can vary by as much as 25 mm Hg between visits.1 The solution to this dilemma is potentially 2-fold: improving the office BP technique (eg, using accurate, validated automated monitors that can take multiple readings) and using out-of-office monitoring to supplement the BP values obtained in the clinical environment. Out-of-office monitoring takes 2 forms at the present time: self–(or home) BP monitoring and ambulatory BP monitoring (ABPM). While both modalities have been available for 30 years, only now are they finding their way into routine clinical practice. The use of self–BP monitoring (also referred to as home BP monitoring) as an adjunct to office BP monitoring has been recommended by several national and international guidelines for the management of hypertension, including those of the European Society of Hypertension,2 the American Society of Hypertension,3 the American Heart Association (AHA),4 the British Hypertension Society,5 the European Society of Hypertension,6 the Japanese Hypertension Society,7 the World Health Organization–International Society of Hypertension,8 and the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure.9 In the United States, the use of self–BP monitoring is growing rapidly: Gallup polls suggest that the proportion of patients who report that they monitor their BP at home increased from 38% in 2000 to 55% in 2005. In contrast, the use of ABPM in clinical practice remains limited, although exact numbers are not available. Ambulatory BP monitors are used only by physicians' offices. They require preprogramming to take readings at preset intervals (typically every 15–30 minutes) throughout the day and night. They are reasonably accurate and are lightweight (≤1 lb). The majority of patients can obtain a full profile of BP and its variability over 24 hours. The hardware and software of ABPM devices have changed little during the past decade. Since the costs of ABPM have not been covered well by third-party payers, their use has been limited in clinical practice. Medicare has granted reimbursement for ABPM, but only for the limited indication of suspected white-coat hypertension with an absence of target organ damage; in our experience, this payment is typically less than the true cost of the procedure. Other insurers are becoming more liberal in reimbursing for ABPM, but prior authorization is the rule rather than the exception. Self-monitoring (home) BP devices have undergone substantial changes during the past decade. The first generation were aneroid devices that were handheld and required manual inflation and deflation. These devices are now rarely used and have been replaced by automated oscillometric devices, which take single readings that are displayed on a liquid crystal display screen. The more basic devices do not have memory or a printer, so patients are required to keep a written log of their BP readings. The accuracy with which patients obtain and write down the BP readings has been found to be questionable.10 Monitors that have been formally validated have been found to be reasonably accurate, but many marketed self-monitoring devices have not been formally tested. As self-monitoring devices are readily available for purchase by patients and are inexpensive, their use has increased rapidly over the past decade. Freestanding devices, such as those found in pharmacies, may not be regularly maintained and may not be reliable. The newest generation of self/home BP monitors has the same BP measurement technique as older devices but has increasingly sophisticated electronics. Many devices have memory so that they can easily co
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Self-citationMancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f0580f · Cited by 1,837
Kario, K., Pickering, T. G., Umeda, Y., Hoshide, S., Hoshide, Y., Morinari, M., Murata, M., Kuroda, T., Schwartz, J. E., & Shimada, K. (2003) · Circulation · doi:10.1161/01.cir.0000056521.67546.aa · Cited by 1,250
Self-citationDolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Mancia, G., Facchetti, R., Bombelli, M., Grassi, G., & Sega, R. (2006) · Hypertension · doi:10.1161/01.hyp.0000215363.69793.bb · Cited by 691
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189011 · Cited by 294
Self-citationAyman, D., & Goldshine, A. D. (1940) · The American Journal of the Medical Sciences · doi:10.1097/00000441-194010000-00005 · Cited by 293
Cited by
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000596 · Cited by 1,127
Shimbo, D., Artinian, N. T., Basile, J. N., Krakoff, L. R., Margolis, K. L., Rakotz, M. K., Wozniak, G., & On behalf of the American Heart Association and the American Medical Association (2020) · Circulation · doi:10.1161/cir.0000000000000803 · Cited by 389
Roush, G. C., Fagard, R. H., Salles, G. F., Pierdomenico, S. D., Reboldi, G., Verdecchia, P., Eguchi, K., Kario, K., Hoshide, S., Polonia, J., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000355 · Cited by 272
Metadata
- Authors
- Pickering, T. G., White, W. B., & on behalf of the American Society of Hypertension Writing Group
- Venue
- The Journal of Clinical Hypertension
- Publisher
- Wiley
- Published
- 2008-11
- Volume
- 10
- Issue
- 11
- Pages
- 850-855
- ISSN
- 1524-6175 (ISSN-L)
- 1751-7176
- OpenAlex
- W2063743992
- Cited by
- 77
- References
- 11
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ASH Position Paper: Home and Ambulatory Blood Pressure Monitoring When and How to Use Self (Home) and Ambulatory Blood Pressure Monitoring. https://app.cochat.ai/papers/10.1111/j.1751-7176.2008.00043.x
- The paper
- Pickering, T. G., White, W. B., & on behalf of the American Society of Hypertension Writing Group. (2008). ASH Position Paper: Home and Ambulatory Blood Pressure Monitoring When and How to Use Self (Home) and Ambulatory Blood Pressure Monitoring. The Journal of Clinical Hypertension. https://doi.org/10.1111/j.1751-7176.2008.00043.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.