Diagnostic Thresholds for Ambulatory Blood Pressure Moving Lower: A Review Based on a Meta‐Analysis—Clinical Implications
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Upper limits of normal ambulatory blood pressure (ABP) have been a matter of debate in recent years. Current diagnostic thresholds for ABP rely mainly on statistical parameters derived from reference populations. Recent findings from the International Database of Ambulatory Blood Pressure in Relation to Cardiovascular Outcome (IDACO) provide outcome‐driven thresholds for ABP. Rounded systolic/diastolic thresholds for optimal ABP were found to be 115/75 mm Hg for 24 hours, 120/80 mm Hg for daytime, and 100/65 mm Hg for nighttime. The corresponding rounded thresholds for normal ABP were 125/75 mm Hg, 130/85 mm Hg, and 110/70 mm Hg, respectively, and those for ambulatory hypertension were 130/80 mm Hg, 140/85 mm Hg, and 120/70 mm Hg. However, in clinical practice, any diagnostic threshold for blood pressure needs to be assessed in the context of the patient's overall risk profile. The IDACO database is therefore being updated with additional population cohorts to enable the construction of multifactorial risk score charts, which also include ABP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Koren, M. J., Devereux, R. B., Casale, P. N., Savage, D. D., & Laragh, J. H. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-5-345 · Cited by 2,366
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationPrognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Self-citationAmbulatory Blood Pressure and Mortality: A Population-Based Study
Hansen, T. W., Jeppesen, J., Rasmussen, S., Ibsen, H., & Torp-Pedersen, C. (2005) · Hypertension · doi:10.1161/01.hyp.0000160402.39597.3b · Cited by 317
Self-citationDiagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk
Kikuya, M., Hansen, T. W., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Ibsen, H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.662254 · Cited by 314
Self-citationWhite coat hypertension.: No harm for the heart.
Gosse, P., Promax, H., Durandet, P., & Clementy, J. (1993) · Hypertension · doi:10.1161/01.hyp.22.5.766 · Cited by 125
Cited by
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000596 · Cited by 1,127
Asferg, C. L., Nielsen, S. J., Andersen, U. B., Linneberg, A., Møller, D. V., Hedley, P. L., Christiansen, M., Goetze, J. P., Esler, M., & Jeppesen, J. L. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00791 · Cited by 58
“Presence of hypertension and normotension was defined according to the recommendations from the International Database on Ambulatory BP monitoring in relation to Cardiovascular Outcomes (IDACO) as a mean 24-hour systolic BP ≥130 mm Hg or a mean 24-hour diastolic BP ≥80 mm Hg, and a mean 24-hour BP <130/80 mm Hg, respe…”
MethodSelf-citationAsferg, C. L., Andersen, U. B., Linneberg, A., Goetze, J. P., & Jeppesen, J. L. (2014) · Diabetic Medicine · doi:10.1111/dme.12411 · Cited by 26
Self-citation
Metadata
- Authors
- Hansen, T. W., Kikuya, M., Thijs, L., Li, Y., Boggia, J., Björklund‐Bodegârd, K., Torp‐Pedersen, C., Jeppesen, J., Ibsen, H., & Staessen, J. A.
- Venue
- The Journal of Clinical Hypertension
- Publisher
- Wiley
- Published
- 2008-05
- Volume
- 10
- Issue
- 5
- Pages
- 377-381
- ISSN
- 1524-6175 (ISSN-L)
- 1751-7176
- OpenAlex
- W2169725114
- Cited by
- 36
- References
- 7
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.