Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Maxillofacial cone beam computed tomography (CBCT) is one of the most significant advances in dental imaging since rotational panoramic radiography. While the acquisition of CBCT data is technically simple, numerous parameters should be considered so that CBCT imaging is performed appropriately and ‘task specific’. This involves an understanding of not only exposure (e.g. geometric and software parameters to minimize patient dose, while sustaining diagnostic image quality) but also image formatting options to maximize image display. CBCT images contain far more detailed information of the maxillofacial region than do panoramic or other 2‐D images and necessitate a thorough knowledge of the 3‐D anatomy of the region and considerations of variability in the range of the anatomically normal. These principles, procedures and protocols, together with the interpretation of CBCT images form the basis of best practices in maxillofacial CBCT imaging. This communication aims to provide: (1) an overview of the fundamental principles of operation of maxillofacial CBCT technology; (2) an understanding of ‘task specific’ equipment, image selection and image display modes; and (3) a systematic methodology for sequencing interpretation of CBCT images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319 · cited 1×
“ric data is the Feldkamp (FDK) algorithm.(12) Once all sinograms have been reconstructed, they can be recombined into a single volume for visualization.”
MethodClinical applications of cone-beam computed tomography in dental practice.
Scarfe, W. C., Farman, A. G., & Sukovic, P. (2006) · PubMed · Cited by 1,528
Self-citationDosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT
Ludlow, J., Davies-Ludlow, L., Brooks, S., & Howerton, W. (2006) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/14340323 · Cited by 851 · cited 1×
“posterior).(21,31,32) Limitation of the FOV to the smallest ROI necessary for diagnosis using mechanical”
BackgroundPrinciples of CT and CT Technology
Goldman, L. W. (2007) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.107.042978 · Cited by 445 · cited 1×
“mitted X-ray attenuation data by specific software algorithms produces adjacent image slices of the imaged volume, usually in the axial plane, perpendicular to the long axis of the object; hence the term computed axial tomography, or ‘CAT’ scan.(5) CT acquisition has subsequently been refined to incorporate a helical…”
MethodDeriving Hounsfield units using grey levels in cone beam computed tomography
Mah, P., Reeves, T. E., & McDavid, W. D. (2010) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/19603304 · Cited by 371
Horner, K., Islam, M., Flygare, L., Tsiklakis, K., & Whaites, E. (2009) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/74941012 · Cited by 370
Hounsfield, G. N. (1980) · Science · doi:10.1126/science.6997993 · Cited by 366
Nackaerts, O., Maes, F., Yan, H., Couto Souza, P., Pauwels, R., & Jacobs, R. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02076.x · Cited by 192 · cited 1×
“In addition, greyscale intensity values measured on CBCT images do not directly represent Hounsfield units (HU), the relative density of body tissues according to a calibrated grey-level scale, based on normalized-HU values for air ()1000 HU), water (0 HU), and dense bone (+1000 HU).(26,27) While these conditions limi…”
BackgroundQu, X., Li, G., Ludlow, J. B., Zhang, Z.-Y., & Ma, X.-C. (2010) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2010.06.013 · Cited by 144 · cited 4×
“posterior).(21,31,32) Limitation of the FOV to the smallest ROI necessary for diagnosis using mechanical”
BackgroundInfluentialCone‐beam computed tomography of the maxillofacial region—an update
Kau, C. H., Božič, M., English, J. D., Lee, R., Bussa, H. I., & Ellis, R. K. (2009) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.279 · Cited by 103 · cited 1×
“CBCT manufacturers approach setting exposure factors in one of two ways.(19) They either provide a selection of ‘fixed’ exposure settings (e.”
Background
Cited by
Khan, A. A., Morrison, A., Hanley, D. A., Felsenberg, D., McCauley, L. K., O'Ryan, F., Reid, I. R., Ruggiero, S. L., Taguchi, A., Tetradis, S., et al. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2405 · Cited by 1,353
Contemporary imaging for the diagnosis and treatment of traumatic dental injuries: A review
Cohenca, N., & Silberman, A. (2017) · Dental Traumatology · doi:10.1111/edt.12339 · Cited by 75
Metadata
- Authors
- Scarfe, W., Li, Z., Aboelmaaty, W., Scott, S., & Farman, A.
- Venue
- Australian Dental Journal
- Publisher
- Wiley
- Published
- 2012-02-29
- Volume
- 57
- Issue
- s1
- Pages
- 46-60
- ISSN
- 0045-0421 (ISSN-L)
- 1834-7819
- OpenAlex
- W2130534151
- Cited by
- 232
- References
- 11
- FWCI
- 16.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.