Twenty-Four-Hour Ambulatory Electrocardiography in Normal Cats

Ware, Wendy A.·1999·Journal of Veterinary Internal Medicine

Abstract

Abstarct: Twenty-four-hour ambulatory electrocardiograms were recorded in two age groups of 10 normal cats each: group 1 (1 to 4 years) and group 2 (8 to 14 years), with equal numbers of males and females in each group. Average heart rates over the 24-hour recording period ranged from 114 to 202 beats/minute (bpm). The mean 24-hour average rate did not differ between group 1 and group 2 (157.6 vs. 156.3 6 5.3 bpm, respectively); however, females (both groups combined) had higher average heart rates than males (166.8 vs. 147.1 6 5.3 bpm, respectively). Females also had a higher mean minimum heart rate than males (116.9 vs. 96.5 6 4.2 bpm, respectively); but there were no gender or age group differences in maximum heart rate. Results of hourly analyses of average, minimum, and maximum heart rates were similar. Mean heart rates rose from mid-afternoon to about 9:00PM and were lowest just after midnight. Although regular sinus rhythm predominated, periods of sinus arrhythmia were evident in most cats, especially in early morning hours. Supraventricular extrasystoles were uncommon. Isolated ventricular extrasystoles occurred more frequently in group 2 cats; multiform configuration was observed in both groups. Repetitive ventricular extrasystoles, which usually consisted of occasional couplets, occurred more frequently in group 2 cats. One older cat had 2 short runs of ventricular tachycardia. Another older cat appeared to have a recurrent accelerated idioventricular rhythm.

Overview

Integrity signals

Registry

Crossref · 10.1111/j.1939-1676.1999.tb02174.x

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 8

  1. Bleifer, 1980, Cardiac Arrythmias, 470
  2. Calvert, 1995, Kirk's Current Veterinary Therapy XII, 799
  3. Moise, 1995, Kirk's Current Veterinary Therapy XII, 792
  4. Rush, 1989, ECG of the month, J Am Vet Med Assoc, 194
  5. Ware, 1998, Practical use of Holter monitoring, Compendium on Continuing Education for the Practicing Veterinarian, 20, 167
  6. Fox, 1998, Analysis of continuous ECG (Holter) monitoring in normal cats and cardiomyopathic cats in congestive heart failure, Abstr J Vet Intern Med, 12, 199
  7. Hamlin, 1989, Heart rate of the cat, J Am Anim Hosp Assoc, 25, 284
  8. Zipes, 1997, Heart Disease: A Textbook of Cardiovascular Medicine, 640

Cited by

Metadata

Authors
Ware, W. A.
Affiliations
Iowa State University (US)
Corresponding author
Ware, Wendy A.
Venue
Journal of Veterinary Internal Medicine
Published
1999-05-01
Volume
13
Issue
3
Pages
175-180
ISSN
  • 0891-6640 (ISSN-L)
  • 1939-1676
OpenAlex
W4313371121
Cited by
34
References
24
Citations by year
2026: 1 · 2024: 3 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 1 · 2018: 5 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 1
FWCI
0.24
Type
journal article
Language
en
Open access
closed
Locations
Journal of Veterinary Internal Medicine (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Veterinary › Small Animals › Veterinary Medicine and Surgery
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
cats, 24-hour ambulatory electrocardiography, heart rate, sinus arrhythmia, premature ventricular contractions, supraventricular extrasystoles, ventricular tachycardia, idioventricular rhythm, sex differences, age differences, circadian variation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.