Programming Implantable Cardioverter‐Defibrillators in Patients with Primary Prevention Indication to Prolong Time to First Shock: Results from the PROVIDE Study
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
ICD Programming for Shock Reduction: Background: Shock therapy delivery by implantable cardioverter‐defibrillators (ICD) can be painful and may have adverse consequences. Reducing shock burden for patients with ICDs would be beneficial. Methods: PROVIDE was a prospective, randomized study of primary prevention ICD patients. Patients in the experimental group received a combination of programmed parameters with higher detection rates, longer detection intervals, empiric antitachycardia pacing (ATP), and optimized supraventricular tachycardia (SVT) discriminators, while those in the control group were programmed with conventional parameters. Shock therapy and arrhythmic syncope were compared. Results: Of 1,670 patients enrolled (846 in the experimental group, 824 in the control group) and monitored over a follow‐up of 530 ± 241 days, 202 patients received shock therapy for any cause (82 in the experimental group and 120 in the control group). The median time to first shock was significantly prolonged (13.1 vs 7.8 months, hazard ratio [HR]: 0.62, 95% confidence interval [CI]: 0.47 to 0.82, P = 0.0005) and the 2‐year shock rate significantly reduced (12.4% vs 19.4%, P < 0.001) in the experimental group compared to the control group. There was no increase in arrhythmic syncope (HR: 1.64, 95% CI: 0.69 to 3.90, P = 0.26), while the overall mortality was reduced (HR: 0.7, 95% CI: 0.50 to 0.98, P = 0.036) in the experimental group compared to the control group. Conclusion: A combination of programmed parameters utilizing higher detection rate, longer detection intervals, empiric ATP, and optimized SVT discriminators reduced ICD therapies without increasing arrhythmic syncope and was associated with reduction in all‐cause mortality among ICD patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489 · cited 1×
“16 The primary exclusion criteria included (1) history of spontaneous sustained VT or VF prior to the implant, (2) inducible sustained VT at a rate below 181 bpm during an electrophysiology test, or (3) presence of ICD or CRT-D device prior to the currently implanted device.”
BackgroundSchron, E. B., Exner, D. V., Yao, Q., Jenkins, L. S., Steinberg, J. S., Cook, J. R., Kutalek, S. P., Friedman, P. L., Bubien, R. S., Page, R. L., et al. (2002) · Circulation · doi:10.1161/hc0502.103330 · Cited by 624
Quality of life in the Canadian Implantable Defibrillator Study (CIDS)
Irvine, J., Dorian, P., Baker, B., O'Brien, B. J., Roberts, R., Gent, M., Newman, D., & Connolly, S. J. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124049 · Cited by 368
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Towbin, J. A., McKenna, W. J., Abrams, D. J., Ackerman, M. J., Calkins, H., Darrieux, F. C. C., Daubert, J. P., de Chillou, C., DePasquale, E. C., Desai, M. Y., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.05.007 · Cited by 846
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Europace · doi:10.1093/europace/euv411 · Cited by 243
“Finally, the Programming Implantable Cardioverter-Defibrillators in Patients With Primary Prevention Indication (PROVIDE) trial randomized 1670 patients to conventional programming (12-beat detection in each of 2 zones) or experimental programming (2 VT and 1 VF zone requiring 25-, 18-, and 12-beat detection, respecti…”
BackgroundImplantable Cardioverter-Defibrillator Therapy in Brugada Syndrome
Conte, G., Sieira, J., Ciconte, G., de Asmundis, C., Chierchia, G.-B., Baltogiannis, G., Di Giovanni, G., La Meir, M., Wellens, F., Czapla, J., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.12.031 · Cited by 199
“Apart from setting high rate cutoffs, a strategy to reduce unnecessary therapies might be the insertion of a high VT zone with supraventricular tachycardia discriminators and a prolonged delay in therapy delivery by increasing the number of intervals to detect (11,19,20).”
Background
Metadata
- Authors
- SAEED, M., HANNA, I., ROBOTIS, D., STYPEREK, R., POLOSAJIAN, L., KHAN, A., ALONSO, J., NABUTOVSKY, Y., & NEASON, C.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2013-09-24
- Volume
- 25
- Issue
- 1
- Pages
- 52-59
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1581369492
- Cited by
- 133
- References
- 5
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Programming Implantable Cardioverter‐Defibrillators in Patients with Primary Prevention Indication to Prolong Time to First Shock: Results from the PROVIDE Study. https://app.cochat.ai/papers/10.1111/jce.12273
- The paper
- SAEED, M., HANNA, I., ROBOTIS, D., STYPEREK, R., POLOSAJIAN, L., KHAN, A., ALONSO, J., NABUTOVSKY, Y., & NEASON, C. (2014). Programming Implantable Cardioverter‐Defibrillators in Patients with Primary Prevention Indication to Prolong Time to First Shock: Results from the PROVIDE Study. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.12273
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.